View
6
Download
0
Category
Preview:
Citation preview
ELIN Motoren GmbHElin-Motoren-Straße 1, 8160 Preding/Weiz, Österreich, T. +43 3172 90606-0, F. +43 3172 90606-1504, contact@elinmotoren.at, www.elinmotoren.at
Gesellschaftssitz Krottendorf, DVR 0748897, Firmenbuchnummer: FN 58429a, Firmenbuchgericht: Handelsgericht Graz, UID-Nr. ATU14773404
BUSINESS DIVISION MINING/PLASTICS - EXTRUDERWE KEEP THE WORLD IN MOTION.
KEY FACTS
WATER JACKET COOLED
MOTORS, EXPERIENCED
AND WELL PROOFED SINCE
1973
AVERAGE SALES GROWTH
LAST 10 YEARS
6% PER ANNO
15.500 SOLD MOTORS
IN THE LAST 10 YEARS
WATER COOLED MOTORS
UP TO 3000 kW
OUR MISSION
INNOVATIVE SOLUTIONS AND
TECHNOLOGIES
OPERATIONAL AND STRATEGIC
PARTNERSHIPS
GENERATE A GLOBAL UNIQUE
SELLING PROPOSITION
OUR VALUES
COMPETENTLY AND
RESPONSIBLY HANDLING
CUSTOMER-SPECIFIC
SOLUTIONS
FLEXIBLE ORDER
PROCESSING
FAST AND DIRECT
COMMUNICATION
SUSTAINABLE USE OF
RESOURCES
A GLOBAL PLAYER FOR ELECTRIC MACHINES
SUZLON GENERATORS LTD. (JV) PUNE, INDIA
ELIN METAL KFT.BÁTONYTERENYE, HUNGARY
ELIN MOTORS BOSNIA D.O.O.ŽIVINICE, BOSNIA
ELIN MOTOREN GMBH HEADQUARTERS
PREDING/ WEIZ, AUSTRIA
OUR LOCATIONS
SERVICE PARTNER
TEST FIELD
POWER:
UP TO 6 MW DIRECT COUPLED
SYSTEM TESTS UP TO 6 MW
(GENERATOR + CONVERTER)
EXAMINATION OF:
• SYNCHRONOUS MACHINES
• ASYNCHRONOUS MACHINES
• DC MACHINES
SUPPLY VOLTAGE:
AC: 400 V UP TO 15 kV
DC: UP TO 600 V
WIND ENERGY MINING/ PLASTICS INDUSTRIAL PROJECTS POWER PLANTS SERVICE
BUSINESS DIVISIONS
ASYNCHRONOUS AND
SYNCHRONOUS
GENERATORS
MOTORS FOR
TUNNEL BORING,
MINING
UNDERGROUND,
EXTRUDER,
MIXER, HYDRAULIC
MOTORS AND
GENERATORS FOR
TEST FIELDS,
INDUSTRIAL PROJECTS,
OIL&GAS AND
MARINE
MOTORS AND
GENERATORS FOR
POWER PLANTS
(THERMAL, HYDRO...),
STEAM TURBINES, GAS
TURBINES, GAS
MOTORS
PARTNERSHIP OVER
THE LIFECYCLE
WATER COOLED MOTORS
LOCAL SERVICES ON-SITE MEASUREMENTSWATER JACKET COOLED
IC 7A0W7
100 – 2500 kW
0,4 – 11 kV
SLIP RING MOTORS
IC81W
500 – 15000 KW
0,4 – 15 kV
WATER COOLED + HEAT EXCHANGER
IC81W
600 – 35000 kW
0,4 – 15 kV
AIR COOLED MOTORS
LOCAL SERVICES ON-SITE MEASUREMENTS
SURFACE COOLED
IC4XX
200 – 2500 kW
0,4 – 11 kV
AIR COOLED
IC6XX
500 – 18000 kW
0,4 – 15 kV
TUBE COOLED
IC5XX
200 – 8000 kW
0,4 – 15 kV
BUSINESS DIVISION MINING/PLASTICS
TUNNEL BORING MACHINES
UP TO 1200 kW
COPE
UP TO 1600 kW
MINING
UP TO 800 kW
BUSINESS DIVISION MINING/PLASTICS
EXTRUDER
UP TO 3000 kW
HYDRAULICS
UP TO 600 kW
MIXER
UP TO 3000 kW
WATER JACKED COOLING SYSTEM
SEPERATING BARS
INNER WATER JACKET
OUTER WATER JACKET
TERMINAL BOX
WATER INLET AND WATER OUTLET
WATER FLOW
COMPARISON IN SIZE
0
50
100
150
200
250
300
350
400
0
500
1 000
1 500
2 000
0
100
200
300
400
500
600
700
800
900
100
0
110
0
120
0
130
0
140
0
150
0
160
0
170
0
180
0
190
0
200
0
Po
we[K
W]
Torq
ue [
Nm
]
Revolution [1/min]
ELIN-Type MKH825F06, 6-pole
0…1300 rpm - const. Torque 1652 Nm
from 1300 rpm - const. Power 225 kW
AC-standard motor, 4-pole, IP54
0…1500 rpm - const. Torque 2005 Nm
from rpm- const. Power 315 kW
Customer requested Vertex
=Vertex for MKH-Winding:
Torque = 1652 Nm at 1300 rpm
Resulted Power = 225 kW
CUSTOMER VALUE OF FLUID COOLED MOTORS
SPACE AND WEIGHT
REDUCTION DUE TO COMPACT
DESIGN AND OMISSION OF
THE INTERNAL FAN
WINDING ADJUSTMENT TO
MEET THE EXACT CUSTOMER
REQUIRED TORQUE AND
ROTATION SPEED
INSENSITIVE TO POLLUTION
AND FLUCTUATION OF
TEMPERATURE OF THE AMBIENT
AIR
CUSTOMER VALUE OF FLUID COOLED MOTORS
THE COOLING SYSTEM
ALLOWS THE OPERATION ON
A FREQUENCY INVERTER
ABOVE THE COMPLETE SPEED-
RANGE (0...MAX SPEED)
WITHOUT ADDITIONAL
COOLING DEVICE. REQUIRES
NO EXTERNAL FAN AS
NECESSARY FOR AIR COOLED
MOTORS.
A COOL SURFACE OF THE
MOTOR HOUSING REDUCES
THE TEMPERATURE OF THE
AMBIENT AIR
CONSIDERABLE DECREASE OF
NOISE AND VIBRATION,
COMPARED WITH TOTALLY
ENCLOSED FAN-COOLED
MOTORS
CUSTOMER VALUE OF FLUID COOLED MOTORS
WASTE HEAT OF MOTOR WILL BE CARRIED OFF BY THE COOLING-CIRCULATION
AND HAS NO IMPACT ON THE IMMEDIATE SURROUNDING:
EXPENSIVE SYSTEMS
OUTGOING AIR CAN BE
AVOIDED
AIR CONDITION IS NOT
NECESSARY
EXPENSIVE SYSTEMS
OUTGOING AIR CAN BE
AVOIDED
MKH - LOW VOLTAGE ASYNCHRONOUS MOTOR
• Possible execution standards IEC 60034, CSA C22.2 No.100 - 14, UL 1004, electric to NEMA MG1
Welded housing, water cooled stator
• IEC Frame size 200 – 500• Power range up to 2000 kW• Speed range operated with VFD 0 -3000 rpm• Voltage up to 1000 V• Standard type of construction• IM B3 (IM1001), IM B35 (IM2001), IM B5 (IM3001),
IM V1 (IM3011) Special type of construction upon request
• Type of protection up to IP67• Insulation class/Temperature rise H• Noise level < 80 dB(A)• Additional Equipment: all typical temperature and vibration sensors, various
Encoder and shaft grounding rings
WATERCOOLED ASYNCHRONOUS MOTORS MKH
FRAME-
SIZE
NO. OF
POLE POWER- AND SPEED- RANGE
200 4- POLE
4- POLE
6- POLE
4- POLE
6- POLE
4- POLE
6- POLE
4- POLE
6- POLE
4- POLE
6- POLE
6- POLE
8- POLE
10- POLE
30
kW
37
kW
45
kW
55
kW
75
kW
90
kW
11
0 k
W
13
2 k
W
16
0 k
W
20
0 k
W
25
0 k
W
31
5 k
W
35
5 k
W
40
0 k
W
45
0 k
W
50
0 k
W
56
0 k
W
63
0 k
W
71
0 k
W
80
0 k
W
90
0 k
W
10
00
kW
11
20
kW
12
50
kW
14
00
kW
16
00
kW
18
00
kW
20
00
kW
22
50
kW
24
00
kW
~1200 … ~2000 1/min
~1200 ... ~2000 1/min
~800 … … ~ 1500 1/min
~1200 ... ~2000 1/min
~800 … ~ 1500 1/min
~800 … ~ 1500 1/min
~1200 … … ~2000 1/min
~600 ... ~1500 1/min
~800 … … ~ 1500 1/min
~400 … … ~ 800 1/min
~1200 ... … ~2000 1/min
~800 … ~ 1500 1/min
~1200 … ~1800 1/min
~500~ 1000 1/min630
355
450
500
250
315
MKS - LOW VOLTAGE ASYNCHRONOUS MOTOR
• Possible execution standards IEC 60034, CSA C22.2 No.100 - 14, UL 1004, electric to NEMA MG1
Welded housing, water cooled stator + additional internal cooling circuit
(radial fan NDE- side on the motor shaft)
• IEC Frame size 630• Power range up to 3000 kW• Speed range operated with VFD 300 - 2000 rpm• Voltage up to 1000 V• Standard type of construction IM B3 (IM1001)
Special type of construction upon request
• Type of protection up to IP65• Insulation class/Temperature rise H• High efficiency class according to international standards• Additional Equipment: all typical temperature and vibration sensors, various
Encoder and shaft grounding rings
HKH - MEDIUM VOLTAGE ASYNCHRONOUS MOTOR
• Possible execution standards IEC 60034, electric to NEMA MG1Welded housing, water cooled stator
• IEC Frame size 355 – 560• Power range up to 3000 kW• Speed range operated with VFD 0 -2000 rpm• Voltage 3,3 kV – 10 kV• Type of construction IM B3 (IM1001)• Type of protection up to IP55• Insulation class/Temperature rise F• Noise level < 80 dB(A)• Additional Equipment: all typical temperature and vibration sensors, various
Encoder and shaft grounding rings
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
380- 690 V
Up to
2618 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
690 V
1830 kW
Application:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
400 V
Up to
900 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
380 - 690 V
Up to
2238 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
380 - 690 V
Up to
1510 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooledand internal cooling circuit
EXTRUDER
1x
MKS863C06
690 V
2420 kW
Application:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
400 V
Up to
500 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooled
EXTRUDER
Various MKH
400 - 690 V
Up to
1080 kWApplication:
Extruder
HIGHLIGHT:
• Water Cooled
FILM STRETCHING MACHINE
Various MKH
380 - 690 V
Up to
2200 kWApplication:
Film stretching machine
Recommended