View
238
Download
0
Category
Preview:
Citation preview
7/26/2019 Hub800_CES_Services v3.0.pdf
1/49
DragonWave Proprietary Data
Harmony Hub800 R2.6Ethernet and CES procedures
3/18/2016
- A -
7/26/2019 Hub800_CES_Services v3.0.pdf
2/49
DragonWave Proprietary Information 2
Objective
The objective of this presentation is to demonstrate how
to configure Ethernet and CES services.
Typical Point to point configuration
7/26/2019 Hub800_CES_Services v3.0.pdf
3/49
DragonWave Proprietary Information 3
Commissioning Procedure
Steps:
1. Create Ethernet services
2. Create CES service
3. Configure Clock Synchronization
4. Monitoring TDM performance
7/26/2019 Hub800_CES_Services v3.0.pdf
4/49
DragonWave Proprietary Information 4
Creating Ethernet Service
1.0 Ethernet Service
7/26/2019 Hub800_CES_Services v3.0.pdf
5/49
DragonWave Proprietary Information 5
1.1 Create Ethernet Service
Select menu Service Management > Ethernet Service >
Service View and click on Create.
7/26/2019 Hub800_CES_Services v3.0.pdf
6/49
DragonWave Proprietary Information 6
1.2 Create Ethernet Service
Enter a Service Name, Service type as E-LAN and
SVLAN ID as default and in this case is 51,
7/26/2019 Hub800_CES_Services v3.0.pdf
7/49
DragonWave Proprietary Information 7
1.3 Create Ethernet Service
Select the 2 ports to be used for the transport service. In this
example we selected CESoP P0/1 and port 0/3. Click Next to
continue.
Select Next to continue
7/26/2019 Hub800_CES_Services v3.0.pdf
8/49
DragonWave Proprietary Information 8
1.4 Create Ethernet Service
Click Next to continue.
7/26/2019 Hub800_CES_Services v3.0.pdf
9/49
DragonWave Proprietary Information 9
1.5 Create Ethernet Service
Leave Service Priority as Priority6.
Click Next to continue
7/26/2019 Hub800_CES_Services v3.0.pdf
10/49
DragonWave Proprietary Information 10
1.6 Create Ethernet Service
Click Apply to create the Ethernet service.
7/26/2019 Hub800_CES_Services v3.0.pdf
11/49
DragonWave Proprietary Information 11
1.6 Create Ethernet Service
When the procedure is complete. Click Close.
7/26/2019 Hub800_CES_Services v3.0.pdf
12/49
DragonWave Proprietary Information 12
End of Creating an Ethernet Service
3/18/2016 Pg.
12
7/26/2019 Hub800_CES_Services v3.0.pdf
13/49
DragonWave Proprietary Information 13
2.0 Circuit Emulation Service
3/18/2016 Pg.
13
7/26/2019 Hub800_CES_Services v3.0.pdf
14/49
DragonWave Proprietary Information 14
2.1 Create CES service
Select menu Service Management > CES Service >
Service View and click on Create.
7/26/2019 Hub800_CES_Services v3.0.pdf
15/49
DragonWave Proprietary Information 15
2.2 Create CES service
Select Operation mode as Advance.
Select PW type as CESoP
7/26/2019 Hub800_CES_Services v3.0.pdf
16/49
DragonWave Proprietary Information 16
2.3 Create CES service
Ensure all timeslot are selected. Confirm Port setting.
Note Remote and Local UDP port setting.
7/26/2019 Hub800_CES_Services v3.0.pdf
17/49
DragonWave Proprietary Information 17
2.4 Create CES service
Enter a Customer VLAN (CVLAN) and Select Add.
Click Next to continue.
7/26/2019 Hub800_CES_Services v3.0.pdf
18/49
DragonWave Proprietary Information 18
2.5 Create CES service
Click Add a Traffic profile if none was created.
Click Next to continue.
7/26/2019 Hub800_CES_Services v3.0.pdf
19/49
DragonWave Proprietary Information 19
2.6 Create CES service
Select the Ethernet service that we created in previous
step. Click Next to continue.
7/26/2019 Hub800_CES_Services v3.0.pdf
20/49
DragonWave Proprietary Information 20
Create CES service
Important Notice
The next step (2.7) is only require when creating the FIRSTCES service.
7/26/2019 Hub800_CES_Services v3.0.pdf
21/49
DragonWave Proprietary Information 21
2.7.1 Create CES service
Enter a Name and Source IP address, Net mask and
Default gateway.
IP address should not be the same class as your management IP address.
7/26/2019 Hub800_CES_Services v3.0.pdf
22/49
DragonWave Proprietary Information 22
2.7.2 Create CES service
Enter Destination IP address. (This is the IP address of the remote CES
service). Click Next to continue.
7/26/2019 Hub800_CES_Services v3.0.pdf
23/49
DragonWave Proprietary Information 23
2.8 Create CES service
Click Apply to create the CES service.
7/26/2019 Hub800_CES_Services v3.0.pdf
24/49
DragonWave Proprietary Information 24
2.9 Create CES service
When the procedure is complete. Click Close.
7/26/2019 Hub800_CES_Services v3.0.pdf
25/49
DragonWave Proprietary Information 25
End of Circuit Emulation Service
7/26/2019 Hub800_CES_Services v3.0.pdf
26/49
DragonWave Proprietary Information 26
3.0 Clock Synchronization
7/26/2019 Hub800_CES_Services v3.0.pdf
27/49
DragonWave Proprietary Information 27
Clock Synchronization
Note
Ethernet port properties PHY master slave selection is
configured as automatic.
TDM clock is derived from the Local PDH (E1 or T1).
If using FPMR, please ensure that SyncE is configure
correctly.
7/26/2019 Hub800_CES_Services v3.0.pdf
28/49
DragonWave Proprietary Information 28
3.1 Configure Clock Synchronization (Local)
Select menu Clock Sync.
Ensure that the Clock Mode is configured as ssm
7/26/2019 Hub800_CES_Services v3.0.pdf
29/49
DragonWave Proprietary Information 29
3.2 Configure Clock Synchronization (Local)
Select menu Clock Sync > Transmit Source Clock for E1/T1/
tab.
Ensure the Output Clock Type is configured as System.
7/26/2019 Hub800_CES_Services v3.0.pdf
30/49
DragonWave Proprietary Information 30
3.3 Configure Clock Synchronization (Local)
Select menu Clock Sync > SSM Configuration for
Ethernet Port tab.
7/26/2019 Hub800_CES_Services v3.0.pdf
31/49
DragonWave Proprietary Information 31
3.4 Configure Clock Synchronization (Local)
Enable SSM on the appropriate Ethernet port.
Highlight row and Click Modify to enable selected port.
7/26/2019 Hub800_CES_Services v3.0.pdf
32/49
DragonWave Proprietary Information 32
3.5 Configure Clock Synchronization (Local)
Select menu Clock Sync > General Sync Configuration.
Click Create to create a sync source.
7/26/2019 Hub800_CES_Services v3.0.pdf
33/49
DragonWave Proprietary Information 33
3.6 Configure Clock Synchronization (Local)
On the pop up window configure at shown.
Ensure the Clock source is the correct PDH (E1/T1).
7/26/2019 Hub800_CES_Services v3.0.pdf
34/49
DragonWave Proprietary Information 34
3.7 Configure Clock Synchronization (Local)
Wait for at least one minute for the Synchronization state
to change to locked.
7/26/2019 Hub800_CES_Services v3.0.pdf
35/49
DragonWave Proprietary Information 35
3.8 Configure Clock Synchronization (Remote)
Select menu Clock Sync.
Ensure that the Clock Mode is configured as ssm
7/26/2019 Hub800_CES_Services v3.0.pdf
36/49
DragonWave Proprietary Information 36
3.9 Configure Clock Synchronization (Remote)
Select menu Clock Sync > Transmit Source Clock for E1/T1/
tab.
Ensure the Output Clock Type is configured as System.
7/26/2019 Hub800_CES_Services v3.0.pdf
37/49
DragonWave Proprietary Information 37
3.10 Configure Clock Synchronization (Remote)
Select menu Clock Sync > SSM Configuration for
Ethernet Port tab.
7/26/2019 Hub800_CES_Services v3.0.pdf
38/49
DragonWave Proprietary Information 38
3.11 Configure Clock Synchronization (Remote)
Enable SSM on the appropriate Ethernet port.
Highlight row and Click Modify to enable selected port.
7/26/2019 Hub800_CES_Services v3.0.pdf
39/49
DragonWave Proprietary Information 39
3.12 Configure Clock Synchronization (Remote)
Select menu Clock Sync > General Sync Configuration.
Click Create to create a sync source.
7/26/2019 Hub800_CES_Services v3.0.pdf
40/49
DragonWave Proprietary Information 40
3.13 Configure Clock Synchronization (Remote)
On the pop up window configure at shown. Ensure the Type is ethPort and the Clock source is the appropriate Ethernet port.
7/26/2019 Hub800_CES_Services v3.0.pdf
41/49
DragonWave Proprietary Information 41
3.14 Configure Clock Synchronization (Remote)
Wait for at least one minute for the Synchronization state
to change to locked.
7/26/2019 Hub800_CES_Services v3.0.pdf
42/49
DragonWave Proprietary Information 42
End of Clock Synchronization
3/18/2016 Pg.
42
7/26/2019 Hub800_CES_Services v3.0.pdf
43/49
DragonWave Proprietary Information 43
4.0 Monitoring TDM Performance
3/18/2016 Pg.
43
7/26/2019 Hub800_CES_Services v3.0.pdf
44/49
DragonWave Proprietary Information 44
4.1 Monitoring TDM Performance
Select menu Performance
7/26/2019 Hub800_CES_Services v3.0.pdf
45/49
DragonWave Proprietary Information 45
4.2 Monitoring TDM Performance
Select PW from the menu tree and Click Enable
performance monitoring.
7/26/2019 Hub800_CES_Services v3.0.pdf
46/49
DragonWave Proprietary Information 46
4.3 Monitoring TDM Performance
To view Performance data. Select PW Performance from
the menu tree.
7/26/2019 Hub800_CES_Services v3.0.pdf
47/49
DragonWave Proprietary Information 47
End of Monitoring TDM Performance
7/26/2019 Hub800_CES_Services v3.0.pdf
48/49
DragonWave Proprietary Information 48
Worksheet Ethernet Services
Local Remote
Normal Service
Interfaces
General Information (Basic Mode)
Service Name
Global ID
Service Type
Service VLAN ID
Assign QoS Policy
Priority
7/26/2019 Hub800_CES_Services v3.0.pdf
49/49
DragonWave Proprietary Information 49
Worksheet CES Services
Local Remote Notes
CES Service
Select TDM Port
Operation Mode
Time Slot
Port
Remote UDP Port
Local UDP Port
CVLAN
Traffic Profile
Number of Frames Default is 8
RTP Header Used Default is Enabled
Jitter Buffer Default is 4ms
Name
Select Ethernet Service
Basic Setting Initial setting only
Name
IP Address
Net Mask
Default Gateway Need to point to the router IP or to self
Config Service
Name
Destination IP
MAC address learning mode Leave as Default
Recommended