6
Module-HE-B-52-WEG-Circuit-Box-w-WEG-Installation-082615 www.hi-velocity.com Module HE-B-52-WEG Circuit Box c/w WEG Variable Speed Drive Installation For the Installation of: Part Name Description Part Number HE-B Electrical Box w/ 110v 1/2 HP WEG Controller For HE-Z/HE-52 Units (110v power) WEG Non-Zoning Controller, HEB Circuit Board, Transformer in Galvanized Box 40120500052

Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

Module-HE-B-52-WEG-Circuit-Box-w-WEG-Installation-082615

www.hi-velocity.com

Module HE-B-52-WEG

Circuit Boxc/w WEG Variable Speed Drive

Installation

For the Installation of:

Part Name Description Part Number

HE-B Electrical Box w/ 110v 1/2 HP WEG Controller

For HE-Z/HE-52 Units(110v power)

WEG Non-Zoning Controller, HEB Circuit Board, Transformer in Galvanized Box 40120500052

Page 2: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

2

www.hi-velocity.com

© 1995-2013 Energy Saving Products Ltd.

1. Turn off power to the fan coil, and allow 5 minutes for power stored in capacitors to dissipate. Remove large access door from fan coil. (Fig. 1)

2. Unplug all thermostat and power wired connections from fan coil, in order to remove motor/blower module. (Figs. 2a, 2b)

3. Unbolt the two blower housing bolts from the fan coils center plate, using a 7/16” wrench. (Fig. 3)

LargeAccess Door

52 Series Control Box Upgrade Installation

Fig. 1 - 52 Series Fan Coil

Fig. 2a

Fig. 3

4. Remove motor/blower module from fan coil by sliding it out. (Figs. 4a, 4b)

Fig. 4a Fig. 4b

Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (2/6)

Module HEB 52 WEGCircuit Box w/WEG Installation (2/6)

Fig. 2b

5. Unplug motor plug from control board. Remove motor ground wire (green/yellow) from the bolt connecting it to the controls plate. (Figs. 5a, 5b)

Fig. 5a Fig. 5b

IMPORTANT - Before you begin, ensure input voltage of WEG Controller matches line input voltage to fan coil.

Page 3: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

3

www.hi-velocity.com

© 1995-2013 Energy Saving Products Ltd.Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (3/6)

Module HEB 52 WEGCircuit Box w/WEG Installation (3/6)

6. Unscrew the four 1/4” screws connecting the control plate to the blower. (Figs. 6a, 6b)

Fig. 6a Fig. 6b

7. Using the provided nut and bolt, connect motor ground wire to the provided ground wire extension. (Figs. 7a, 7b)

Fig. 7a Fig. 7b

8. Insert ground wire extension into 4-prong motor plug. (Fig. 8)

9. After all controls have been removed off of the blower housing, slide the blower/motor module back into the fan coil casing. (Figs. 9a, 9b)

Fig. 9a Fig. 9b

Fig. 8

10. Replace the two blower bolts securing the blower housing to the center plate using a 7/16” wrench. (Figs. 10)

Fig. 10

11. Before mounting the new 52 controls upgrade box, ensure you connect the male motor plug to the female plug on the bottom side of the new controls box. (Figs. 11a, 11b, 11c)

Fig. 11a Fig. 11b Fig. 11c

52 Series Control Box Upgrade Installation

Page 4: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

4

www.hi-velocity.com

© 1995-2013 Energy Saving Products Ltd.Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6)

Module HEB 52 WEGCircuit Box w/WEG Installation (4/6)

12. Now that the motor plug is connected, the control box can be mounted in place of the large access door. (Figs. 12a, 12b)

Fig. 12a Fig. 12b

13. Reconnect power & thermostat connections to the new circuit board. Hook up ground wire with the provided wire nut. Refer to wiring diagram on last page. (Figs. 13a-13c)

14. Double check that all wiring is done correctly according to wiring diagram. Turn power back on and refer to wiring diagram or to page 30 of the HE-B Install Manual for instructions on how to set fan speed/airflows. (Fig. 14)

Fig. 13a

Fig. 14

Fig. 13b Fig. 13c

15. After all fan speed/airflows have been set, the provided coverplate can be screwed on with provided screws to cover the controls section of box. (Figs. 15a, 15b)

16. With the cover plate secured, stick the provided wiring diagram sticker to the cover plate for future reference.

Fig. 15a Fig. 15b

52 Series Control Box Upgrade Installation

Page 5: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

5

www.hi-velocity.com

© 1995-2013 Energy Saving Products Ltd.Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (5/6)

Module HEB 52 WEGCircuit Box w/WEG Installation (5/6)

52 Series Control Box Upgrade Wiring Diagram T

HE

RM

OS

TA

T C

ON

NE

CT

ION

S

R -

EM

ER

GE

NC

Y D

ISC

ON

NE

CT

C - 2

4 V

AC

CO

MM

ON

C - 2

4 V

AC

CO

MM

ON

Ro

- 24 V

AC

OU

TP

UT

Ri - 2

4 V

AC

INP

UT

24 V

AC

OU

TP

UT

W1 - F

IRS

T S

TA

GE

HE

AT

W2 - S

EC

ON

D S

TA

GE

HE

AT

(OR

SIN

GL

E S

TA

GE

)

Y1 - F

IRS

T S

TA

GE

CO

OL

ING

Y2 - S

EC

ON

D S

TA

GE

CO

OL

ING

(OR

SIN

GL

E S

TA

GE

)

C - 2

4 V

AC

CO

MM

ON

G - T

HE

RM

OS

TA

T F

AN

SW

ITC

H

D - D

EH

UM

IDIF

ICA

TIO

N S

PE

ED

O/B

- HE

AT

PU

MP

RE

VE

RS

ING

NO

TE

S:

1) U

SE

TH

ER

MO

ST

AT

FA

N S

WIT

CH

TO

DIS

AB

LE

/EN

AB

LE

CO

NT

INU

OU

S F

AN

.

2) ‘C

’ TE

RM

INA

L O

N T

HE

RM

OS

TA

T (C

OM

MO

N) IS

NO

T N

EE

DE

D F

OR

SO

ME

TH

ER

MO

ST

AT

S C

ON

SU

LT

TH

ER

MO

ST

AT

INS

TR

UC

TIO

NS

FO

R D

ET

AIL

S.

3) W

1 A

ND

W2 A

CT

IVA

TE

S A

UX

ILIA

RY

RE

LA

Y (A

3) O

N C

AL

L A

ND

CA

N B

E U

SE

D

WIT

H A

1 A

ND

/OR

A2 A

S D

RY

CO

NT

AC

TS

, AR

ME

D 2

4V

AC

FR

OM

TH

E ‘R

TE

RM

INA

L, O

R A

RM

ED

11

0v F

RO

M T

HE

‘L’ T

ER

MIN

AL

.

4) A

UX

ILIA

RY

HE

AT

ING

RE

LA

Y T

IME

R A

CT

IVA

TE

S C

IRC

UIT

FO

R 5

MIN

UT

ES

EV

ER

Y

24 H

OU

RS

ST

AR

TIN

G W

HE

N P

OW

ER

IS A

PP

LIE

D T

O T

HE

UN

IT.

5) S

EE

INS

TA

LL

AT

ION

MA

NU

AL F

OR

MO

RE

DE

TA

ILE

D W

IRIN

G D

IAG

RA

MS

.

6)

7) F

AIL

UR

E T

O S

ET

PR

OP

ER

AIR

FL

OW

AN

D/O

R O

PE

RA

TIO

N O

F T

HE

SY

ST

EM

MA

Y

RE

SU

LT

IN D

AM

AG

E T

O E

QU

IPM

EN

T.

8) F

AIL

UR

E T

O R

EA

D A

ND

FO

LL

OW

AL

L IN

ST

RU

CT

ION

S C

AR

EF

UL

LY

BE

FO

RE

INS

TA

LL

AT

ION

CO

UL

D C

AU

SE

PE

RS

ON

AL IN

JU

RY

AN

D/O

R P

RO

PE

RT

Y D

AM

AG

E.

9) E

NS

UR

E T

HA

T T

HE

FIL

TE

R IS

KE

PT

CL

EA

N A

T A

LL T

IME

S.

10

) MO

TO

R H

AS

PE

RM

AN

EN

T L

UB

E B

EA

RIN

GS

AN

D D

OE

S N

OT

RE

QU

IRE

OIL

ING

.

11

) WA

RR

AN

TY

VO

ID IF

FA

N C

OIL

UN

IT IS

US

ED

DU

RIN

G C

ON

ST

RU

CT

ION

.

FO

R S

ING

LE

ST

AG

E C

OO

LIN

G O

PE

RA

TIO

N U

SE

Y2

, OT

HE

RW

ISE

TH

E F

RE

EZ

E

ST

AT

WIL

L B

E B

YP

AS

SE

D.

FA

N S

PE

ED

AD

JU

ST

ME

NT

(CO

OL

ING

, HE

AT

ING

OR

RE

CIR

CU

LA

TIO

N F

AN

)

- PO

WE

R F

AN

CO

IL U

NIT

.

- - EN

ER

GIZ

E T

HE

TH

ER

MO

ST

AT

SE

TT

ING

TO

BE

AD

JU

ST

ED

. (CO

OL

ING

, HE

AT

ING

OR

RE

CIR

CU

LA

TIO

N F

AN

).

- ON

TH

E W

EG

-CF

W1

0 P

RE

SS

TH

E P

AR

AM

ET

ER

BU

TT

ON

(P) U

NT

IL T

HE

PA

RA

ME

TE

R L

IGH

T (R

ED

) IS IL

LU

MIN

AT

ED

.

- US

ING

TH

E A

RR

OW

BU

TT

ON

S S

CR

OL

L D

OW

N T

O P

AR

AM

ET

ER

“0

00

”.

- PR

ES

S T

HE

PA

RA

ME

TE

R B

UT

TO

N (P

) AG

AIN

TO

EN

TE

R T

HE

PA

RA

ME

TE

R “

00

0”.

- CH

AN

GE

P-0

00 T

O A

VA

LU

E O

F “

00

5”. T

HIS

UN

LO

CK

S T

HE

DR

IVE

AN

D A

LL

OW

S

YO

U T

O C

HA

NG

E O

TH

ER

PA

RA

ME

TE

RS

.

- ON

CE

PA

RA

ME

TE

R “

00

0” IS

SE

T T

O A

VA

LU

E O

F “

00

5” T

HE

DR

IVE

IS U

NL

OC

KE

D

TH

E F

AN

SP

EE

DS

CA

N B

E A

DJU

ST

ED

VIA

PA

RA

ME

TE

RS

12

8, 1

29

, 13

0 A

ND

13

1.

► 0

0.0

HZ

IS T

HE

MIN

IMU

M S

PE

ED

- 66

.0H

Z IS

TH

E M

AX

IMU

M S

PE

ED

.

► P

AR

AM

ET

ER

12

8 (P

-12

8) IS

TO

SE

T T

HE

CO

NS

TA

NT

FA

N S

PE

ED

(G).

► P

AR

AM

ET

ER

12

9 (P

-12

9) IS

TO

SE

T T

HE

CO

OL

ING

SP

EE

D (Y

1 &

Y2

).

► P

AR

AM

ET

ER

13

0 (P

-13

0) IS

TO

SE

T T

HE

HE

AT

ING

SP

EE

D (W

1 &

W2

).

► P

AR

AM

ET

ER

13

1 (P

-13

1) IS

TO

SE

T T

HE

DE

HU

MID

IFIC

AT

ION

SP

EE

D (D

).

RE

FE

R A

ND

CO

MP

LE

TE

CO

MM

ISS

ION

ING

RE

PO

RT

PR

IOR

TO

NO

RM

AL

OP

ER

AT

ION

. FO

R F

UL

L D

ET

AIL

S, R

EP

OR

T IS

PR

OV

IDE

D W

ITH

TH

E

INS

TA

LL

AT

ION

MA

NU

AL O

R O

NL

INE

AT

WW

W.H

I-VE

LO

CIT

Y.C

OM

.

EN

SU

RE

AL

L O

UT

LE

TS

AR

E O

PE

N.

08

26

15

HE

-B 1

10V

JU

MP

ER

PIN

SE

TT

ING

S

AU

XIL

IAR

Y R

EL

AY

TIM

ER

(SE

E

NO

TE

S).

LE

D L

IGH

T IN

DIC

AT

OR

S

LE

D - G

RE

EN

LIG

HT, P

UM

P T

IME

R

H1 E

ME

RG

EN

CY

DIS

CO

NN

EC

T: R

EM

OV

E P

IN IF

WIR

ED

TO

EM

ER

GE

NC

Y D

ISC

ON

NE

CT.

H3 T

IME

R:

AU

XIL

IAR

Y H

EA

TIN

G R

EL

AY

24

VA

C O

UT

PU

T C

ON

NE

CT

ION

S

FZ

- FR

EE

ZE

ST

AT

FZ

- FR

EE

ZE

ST

AT

W1 - H

EA

TIN

G (W

1) 2

4 V

AC

OU

TP

UT

W2 - H

EA

TIN

G (W

2) 2

4 V

AC

OU

TP

UT

Y2 - C

ON

DE

NS

ING

UN

IT 2

4 V

AC

OU

TP

UT

Y1 - C

ON

DE

NS

ING

UN

IT 2

4 V

AC

OU

TP

UT

C - 2

4 V

AC

CO

MM

ON

R - 2

4 V

AC

OU

TP

UT

N - N

EU

TR

AL

L - L

INE

VO

LT

AG

E

A1 - A

UX

ILIA

RY

NO

RM

AL

LY

OP

EN

A2 - A

UX

ILIA

RY

NO

RM

AL

LY

CL

OS

ED

A3 - A

UX

ILIA

RY

CO

MM

ON

To

un

loc

k d

rive c

ha

ng

e to

00

5

To d

isp

lay H

z o

utp

ut

Driv

e H

ea

tsin

k Te

mp

era

ture

To a

dju

st C

on

sta

nt F

an S

pe

ed

To a

dju

st C

oo

ling F

an S

pe

ed

To a

dju

st H

ea

ting F

an S

pe

ed

To a

dju

st D

eh

um

idific

atio

n F

an S

pe

ed

P-0

00

P-0

02

P-0

08

P-1

28

P-1

29

P-1

30

P-1

31

Use

ful P

ara

me

ters

ON

: (AC

TIV

E)

PU

MP

TIM

ER

STA

TU

S

ON

: (INA

CT

IVE

)

OF

F:

2 S

EC

ON

DS

PO

WE

R IN

PU

T: 11

0-1

27

/1/5

0-6

0

L

N

Ground

WH

BK

GLIN

E IN

W1

W2

CR

Y2

Y1

DO

/BG

AUXILIARY RELAY(HEATING)

L2

L2

NL

1L

1 A3A2A1 LN

J5

J4

J3

J2

N CRi Ro

H1J9

J1

HE

B C

IRC

UIT

BO

AR

D

TH

ER

MO

STA

T

EMERGENCY DISCONNECT

C

11

0-1

27

VA

C110-1

27/1

/50-6

0

RY1W2W1FZFZ Y2 CF1

ON

OF

F

H3

TIM

ER

J7

F CHG

24v OUTPUT

31

8.2

8 P

cb

w-0

02

se

p-0

43

1 2

3 4

5 6

7 8

9 1

0 1

1 1

2

L/L

1N

/L2

UV

WP

E

P

0I

Para

mete

r

Valu

e

WEG CONTROLLER

VF

D

11

0-1

20

VA

C

Eq

uip

me

nt

Gro

un

d

BK

WH

GR

MO

TO

R L

EA

DS

PL

UG

(3 P

HA

SE

)

CH

FG

24v / 2

0va

TR

AN

SF

OR

ME

R

BL

UE

/BK

GR

EE

N

WH

ITE

YE

LL

OW

110-1

27v P

OW

ER

CA

BL

E

L2

L2

NL

1L

1

Bla

ck

Ora

ng

e

Wh

ite

Red

CA

UT

ION

FO

R S

ING

LE

ST

AG

EC

OO

LIN

G O

PE

RA

TIO

N

US

E Y

2 O

TH

ER

WIS

E T

HE

F

RE

EZ

E S

TA

T W

ILL

BE

BY

PA

SS

ED

Page 6: Module HE-B-52-WEG · Module-HEB-52-WEG-Circuit-Box-w-WEG-Installation (4/6) Module HEB 52 WEG Circuit Box w/WEG Installation (4/6) 12. Now that the motor plug is connected, the control

TM

Energy Saving Products Ltd., established in 1983, manufactures the Hi-Velocity SystemsTM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support.

For all of your Heating, Cooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you!

Phone: 780-453-2093 Fax: 780-453-1932

Toll Free: 1-888-652-2219

www.hi–velocity.com

Hi-Velocity HE-Z Fan Coils, Green TechnologyBuild Smart, Breathe Easy

Small Duct Heating, Cooling and IAQ Systems