6
Muhammad Umair Rawalpindi, Pakistan Ph: +92-345-5919582; Mobile: +92-315-5852525 Skype: umair.mirza241 [email protected] OBJECTIVE: To acquire a challenging position in an organization, where the organization itself is always through a process of learning and where its people believe on common vision, teamwork & respect each other. WORKING EXPERIENCE: Askari Bank Ltd (ITG) ETD Dates: April 2015 – present Job Title: Officer DC Facilities and Operations Area of Work: Managing Infrastructure Reporting to the Manager DC Facilities & Operations and is responsible for ensuring that the vendor in Askari Bank are available on 24/7 basis monitoring. Instruct and managed following task with assistance of vendors. Implement and coordinate the creation of technical service procedures, policies, and manuals. Installation of APC UPS in Data Center with complete racking and power wiring/cabling. Troubleshooting of APC UPS regarding power modules failure issues. Troubleshooting of APC in Row cooling units regarding changing of fan modules, Variable Frequency Drive (VFD), and Supply Air High Temperature Violation. Have good knowledge about Dx, Chilled water cooling units and how precision cooling differs from comfort cooling. Working on Power Distributing Units (PDU) and Power Distributing Modules (PDM) Monitoring video surveillance (CCTV) in Data Center. Monitoring of Vesda and Fire Suppression through Infrastructure (ISX APC) manager. Monitoring of Biometric device for DC security. Patch paneling and powering the servers & server installation. Hourly reporting of readings (UPS in/out volts/amp, current load and capacity) and logs. Perform support & administration. Operation of Generators Cater Pillar 455kva. And automatic and manual load shifting from ATS Panel. Maintaining redundant power source i.e. Generator ready to provide 100% availability in case of utility fails.

Muhammad Umair - Combined

Embed Size (px)

Citation preview

Page 1: Muhammad Umair - Combined

Muhammad Umair Rawalpindi, Pakistan

Ph: +92-345-5919582; Mobile: +92-315-5852525Skype: [email protected]

OBJECTIVE:

To acquire a challenging position in an organization, where the organization itself is always through a process of learning and where its people believe on common vision, teamwork & respect each other.

WORKING EXPERIENCE:

Askari Bank Ltd (ITG) ETD

Dates: April 2015 – presentJob Title: Officer DC Facilities and OperationsArea of Work:

Managing Infrastructure

Reporting to the Manager DC Facilities & Operations and is responsible for ensuring that the vendor in Askari Bank are available on 24/7 basis monitoring.

Instruct and managed following task with assistance of vendors. Implement and coordinate the creation of technical service procedures, policies, and manuals. Installation of APC UPS in Data Center with complete racking and power wiring/cabling. Troubleshooting of APC UPS regarding power modules failure issues. Troubleshooting of APC in Row cooling units regarding changing of fan modules, Variable

Frequency Drive (VFD), and Supply Air High Temperature Violation. Have good knowledge about Dx, Chilled water cooling units and how precision cooling differs from

comfort cooling. Working on Power Distributing Units (PDU) and Power Distributing Modules (PDM) Monitoring video surveillance (CCTV) in Data Center. Monitoring of Vesda and Fire Suppression through Infrastructure (ISX APC) manager. Monitoring of Biometric device for DC security. Patch paneling and powering the servers & server installation. Hourly reporting of readings (UPS in/out volts/amp, current load and capacity) and logs. Perform support & administration. Operation of Generators Cater Pillar 455kva. And automatic and manual load shifting from ATS

Panel. Maintaining redundant power source i.e. Generator ready to provide 100% availability in case of

utility fails. Support Operating Systems Administration, Installation & other related task of system administration. Good skills about Linux/ UNIX /Aix command line administration. Good knowledge about Engage in strengthening of monitoring by performing shift duties for 24*7 monitoring of NOC when required. Any other task assigned by Manager DC Facilities & Operations / Head Data Center & Infrastructure

Operations.Backup Administrator

Perform Backup Systems (Networker & TSM) support & administration. Perform Tape Library & Media Management / Handling including offsite movement & retrieval. Reusage /

recycling of expired media. TSM client/server installations, maintenance, Tape handling and monitoring. Assist to manage ITM (IBM Integrated Monitoring ) Portal for monitor through Dashboard Production Environment like Flex cube Applications, Oracle financials, people soft applications

etc. Managing latest technology like IBM P595, P570 using data storage backups of LPARS through TSM Server

6.2.2 and Tape Library TS3310 for a 24x7 services which needs a very high standard of Systems, and Data integrity and consistency.

Page 2: Muhammad Umair - Combined

Preparing EMC Networker server. Manage EMC Networker backup administration in AIX, Linux, UNIX, Windows Environment etc. Networker server implementation and client installation on various Operating Systems like AIX, Linux,

UNIX, Windows etc. Implement and manage Networker Server network fiber cable zoning from Networker server to Tape Drive

and Tape Library SL48. Manage Tape library SL48 SUN Microsystems and Full heighted Tape Drives. Networker Offsite Media Management Operation on daily basis. Responsible for implementing and coordinating the core banking solutions to be implemented by the bank. System administration, planning, security, auditing & hardware recommendations. Maintained backup scheduling, Health Monitoring & maintenance activities for Networker Server. Installation and configuration of LAN free Backup on different operating systems like AIX, UNIX, Linux,

Windows etc. Manage Reporting mechanism on daily basis Monitoring. Audit application backup policies and environments to ensure integrity of backup and recovery activities Responsibilities include providing 24 X 7 offshore/remote supports. Mount, install and configure Data Domain system, DD2500 appliance. Can create VTLs, DD boost devices and all task related to data domain system. Assist to manage bare metal Recovery of Client machines. Assist to manage Hyper-V Cluster Nodes environment.

Punjab groups of colleges

Dates: Jan 2015 – presentJob Title: LAB & IT ManagerArea of Work: Network security, Computer hardware and software operations and maintenance, conducting C++ labs, other assigned management tasks.

500 KV Grid Station NTDC WAPDA Rawat

Dates: March 2014 – Dec, 2014Job Title: Trainee EngineerArea of Work: During this aforesaid period I was attached with Protection and instrumentation Department focusing on protection system of Transmission lines and Grid Station Equipments including Transformers.

Functions of all equipments including surge arrestor, PT’s, Wave Traps, Shunt Reactors, CT’s, CCVT’s, Isolators, Bus bars, Bays, circuit breakers, earth switch, Power and auto transformers, insulators, switch gears and relays.

Operation and testing’s of relays, Circuit Breakers, Isolators, CT/PT, CCT/CCVT, Bus Bars and Insulators.

Review of IFC drawings for Grid Stations, Switchgears, EHV cable laying & terminations and Control-protections of the Substation equipments.

Involved in pre- commissioning Electrical tests of power cable, Such as: leakage current test, link resistance test, Conductor Resistance, Capacitance & Impedance measurement and its HVAC test.

Installations of Power and Distribution Transformers with its control &protection arrangements. Monitored different testing’s of transformers like short circuit, open circuit, impulse, CADF winding

resistance, and TTR and polarity tests. More over performed other commissioning tests in Laboratory like ratio test insulation test, core test and saturation test.

Repairs of Cable terminal box and bushing in power& Distribution transformer. Installation of new bushes of shunt reactor. Installation and maintenance of Switchgear , Control and Relay Panels associate with its connection

arrangements. Erections of Outdoor switching equipments with all protective and controlling devices like as CTs, PTs,

& Isolator, Breaker, Bus bar .

Page 3: Muhammad Umair - Combined

Monitoring of SF6 gas pressure in Circuit Breakers and their refilling with SF6 gas. Also deals with the purity test and dew point test of SF6 gas.

Testing of CT’s, PT’s ratio test applying high current source. Installation and maintenance of Control & Relay panel In Control Room. Relay testing using Dolby, Severker and FREJA 306, 300 testing devices. Tested differential protection

relays, distance, over current, over flux, bucholz relay, rough balance, thermal over balance, neutral O/c relay, overload relays and restricted earth fault relays.

Using of RELAY SOFTWARES like DIGSI, S1 AGILE, CAP 530, PCM 600 etc for relay configuration and fault analysis.

Interactive Group of Companies

Dates: Oct, 2013 to Jan, 2014Job Title: Resident EngineerArea of Work: Worked in Data Centers

Gained command over working and maintenance of Data Centers having Gen-sets, UPS’s, Auto Bus Couplers, Two Way Power Sources, Cooling Devices, Power Cables and their reliable connections, Networking of Servers.Protection of Data Centers using FM200 fire Extinguishers, and their remote connections on ISX centrals.

500 KV Grid Station NTDC WAPDA Rawat

Dates: July 2012 –Aug 2012Job Title: Internee Area of Work: Attached with operation and maintenance departmentBrief introduction about Grid Station Equipments and their arrangements. Maintenance of equipments like refilling of circuit breakers SF6 gas, fortifying against corrosive action and operations performed on these equipments in fault times.

PROJECTS:

Power management system

Hybrid power management system (HPMS) is the ability to support and provide the management, monitoring, and control of all power sources. We used AC power from main distributor and Solar energy to make a semi hybrid system.

Installation of CCTV Cameras Motion detection using PIR sensor

Auto speed controlled fan FM transceivers

Home security system Smoke detector

ACADEMIC QUALIFICATION:

Qualification Institution Years Marks Grades / Division (All

Page 4: Muhammad Umair - Combined

obtained/ Total semesters/years)

MS BA Virtual University Pakistan

2014 2016 continue -

BSc Electrical Engineering

Wah Engineering College

University Of Wah

2009 2013 2.83/4 A

HSSCFazaia Inter College Jinnah Camp Khanna Road Rwp

2006 2008 717/1100 B

SSCFazaia Inter College Jinnah Camp Khanna Road Rwp

2004 2006 832/1050 A

PERSONAL SKILLS:

Team-Player with excellent communication skills Quick learner Self-motivated with a strong work ethic for professionalism and timeliness Motivated self-starter with a strong desire to learn

PERSONAL INFORMATION:

Father Name: Shahid Parvez

Date of Birth: 8th Sep, 1990

Address: House # B I 1308 St # 8 Haji Chowk Muslim Town Sadiqabad Rawalpindi

Domicile: Punjab District: Rawalpindi Home Telephone: 051-4576106

Languages :

English Urdu Punjabi