    Type Tables

    7

    Type table for 24 V units

    Type Mains current Power factor Efficiency Dissipated Dimensions Weightsat at 29 V and at 29 V and power in H x W x D in

    3 x 400 V rated current rated current kW (mm) kpD 400 G 26/ 400 BWLrug-Dt 29 0,7 83 % 2,4 2200 x 800 x 800 680D 400 G 26/ 600 BWLrug-Dt 43 0,7 84 % 3,3 2200 x 800 x 800 800D 400 G 26/ 800 BWLrug-Dt 57 0,7 84 % 4,4 2200 x 1200 x 800 950D 400 G 26/1000 BWLrug-Dt 71 0,7 85 % 5,2 2200 x 1200 x 800 1100D 400 G 26/1200 BWLrug-Dt 85 0,7 85 % 6,2 2200 x 1200 x 800 1200D 400 G 26/1600 BWLrug-Dt 112 0,7 86 % 7,6 2200 x 1600 x 800 1500D 400 G 26/2000 BWLrug-Dt 138 0,7 87 % 8,7 2200 x 1600 x 800 1900D 400 G 26/2500 BWLrug-Dt 173 0,7 87 % 10,8 2200 x 2000 x 800 2300D 400 G 26/3000 BWLrug-Dt 207 0,7 88 % 12,9 2200 x 2000 x 800 2650

    Type table for 110 V units

    Type Mains current Power factor Efficiency at Dissipated Dimensions Weightsat at 121 V and 121 V and power in H x W x D in

    3 x 400 V rated current rated current kW (mm) kpD 400 G 108/ 200 BWLrug-Dt 54 0,7 90 % 2,5 2200 x 1000 x 800 620D 400 G 108/ 300 BWLrug-Dt 80 0,7 90 % 3,6 2200 x 1200 x 800 850D 400 G 108/ 400 BWLrug-Dt 105 0,7 91 % 4,4 2200 x 1200 x 800 1120D 400 G 108/ 600 BWLrug-Dt 160 0,7 92 % 5,8 2200 x 1600 x 800 1500D 400 G 108/ 800 BWLrug-Dt 210 0,7 92 % 7,7 2200 x 1600 x 800 1750D 400 G 108/1000 BWLrug-Dt 265 0,7 93 % 8,4 2200 x 2000 x 800 1900D 400 G 108/1200 BWLrug-Dt 315 0,7 93 % 10,1 2200 x 2400 x 800 2080D 400 G 108/1600 BWLrug-Dt 420 0,7 94 % 11,6 2200 x 3200 x 800 2400

    Type table for 220 V units

    Type Mains current Power factor Efficiency at Dissipated Dimensions Weightsat at 245 V and 245 V and power in H x W x D in

    3 x 400 V rated current rated current kW (mm) kpD 400 G 212/ 100 BWLrug-Dt 54 0,7 93 % 1,9 2200 x 800 x 800 530D 400 G 212/ 200 BWLrug-Dt 107 0,7 95 % 2,7 2200 x 1200 x 800 1030D 400 G 212/ 300 BWLrug-Dt 160 0,7 95 % 3,9 2200 x 1600 x 800 1480D 400 G 212/ 400 BWLrug-Dt 210 0,7 96 % 4,2 2200 x 1600 x 800 1700D 400 G 212/ 600 BWLrug-Dt 316 0,7 96 % 5,8 2200 x 1600 x 800 1900D 400 G 212/ 800 BWLrug-Dt 418 0,7 97 % 6,1 2200 x 2400 x 800 2300D 400 G 212/1000 BWLrug-Dt 521 0,7 97 % 7,6 2200 x 3200 x 800 2800D 400 G 212/1200 BWLrug-Dt 625 0,7 97 % 9,1 2200 x 3200 x 800 3200

    Type of cabinet H W1 D

    PS 220808 2200 800 800PS 221008 2200 1000 800

    H

    W1 D 20

    Type of cabinet H W2 D

    PS 221208 2200 1200 800PS 221608 2200 1600 800PS 222008 2200 2000 800

    Dimensions Diagrams

    W2 D 20

  • 8/8/2019 Rectifier 02

    8/8

    Type Table

    Type Fuse size Batt. fuse Dimensions in mm WeightA H W D kg

    BES 250 NH 2 250 2200 800 800 150BES 400 NH 3 400 2200 800 800 150BES 630 NH 3 630 2200 800 800 150BES 1250 NH 4 1250 2200 800 800 170BES 1600 NH 4 1600 2200 800 800 170BES 2500 2 x NH 4 2 x 1250 2200 1000 800 200BES 3200 2 x NH 4 2 x 1600 2200 1000 800 200

    Battery

    Supply

    Units

    GeneralThe battery supply unit connects the power supply to thebattery, and is designed as a floor standing sheet steel cabinet,with hinged front door and corresponding KKS marking.

    The unit should stand adjacent to the power supply, and isconnected via copper bus bar.

    The connection to the battery can be via parallel single corecable or copper bus bar. The unit can be provided with top orbottom cable entry.

    The requirements of the UVV BGV A2 are met, especially withregard to protection against accidental contact.

    EquipmentThe standard battery supply units are equipped as follows:

    NH-fused load disconnection switch equipped with thecorresponding battery fuses with fuse monitoring.

    battery circuit monitoring (BK), either as BK withcharging current measuring or as BS (batterysymmetry monitoring) with centre tap of the battery

    2-pole push-button and the corresponding fuses andresistors for charging the smoothing capacitors in thepower supply units before putting in the battery fuses

    ammeter with middle zero point for the measurement ofthe battery current

    voltmeter for the battery voltage with the correspondingfusing

    lamp fault copper bars and connection plates for the battery andload cables as well as the cross bar to the rectifier

    KKS-marking as engraved plastic label

    RatingThe battery supply units can optionally be delivered for 24 V,110 V and for 220 V in different current sizes. The standardcurrent allocations can be taken from the type table.