TIPL CALIBRATION LABORATORY

AJMER

Toshniwal Industries Pvt. Ltd.Industrial Estate, Makhupura,Ajmer - 305 002 (India)Tel: 0145-2695171Fax: 0145-2695174

Contact

Ajmer | Ahmedabad I Bangalore I Bhillai I Bhubaneshwar I Chandigarh I Chennai I Delhi I Hyderabad I Jamshedpur I Kolkata I Lucknow I Mumbai | Nagpur I Pune | Raipur I Vadodara

Calibration Facility

Local Contact

Electro-Technical DC Voltage BMC 0.004% typical DC Current BMC 0.011% typical DC Resistance BMC 0.012% typicalThermal-Contact Temperature Measurement RTD/ Thermocouple BMC 0.16°C typical Non-Contact Temperature Measurement Infrared Radiation Sensing BMC 0.6°C Optical Pyrometer BMC 9°C typical

Major Test Equipment/ Facility

KEITHLEY 6½ Digit MultimeterVICTOR V/mA CalibratorCambridge Precision BridgeVICTOR Temperature CalibratorISOTEC PRT, T/C Probe & Dry Block FurnaceCHINO Black Body FurnaceLAND Tungsten Strip Lamp calibration Bench

TIPL CALIBRATION LABORATORY, situated in Ajmer is a unit of Toshniwal Industries Pvt. Ltd., a leading company manufacturing Test Measurement and Process Control instruments since more than 50 years. TIPL CALIBRATION LABORATORY is inherited by expertise in Thermal & Electro-Technical calibration derived through rich experience of 50 years.TIPL CALIBRATION LABORATORY follows requirements of International standard ISO/IEC 17025:2005. Our mission statement is “Leadership through Customer Satisfaction & Technology”.TIPL CALIBRATION LABORATORY received NABL accreditation on 05/08/2011 vide NABL certificate No. C-0759 for Electro-Technical and C-0750 for Thermal calibration facility.

TIPL CALIBRATION Laboratory's Electro-technical facility has capability to calibrate DC Voltage, Current & Resistance, with precision of as low as 0.004%, and is equipped with high precision Multimeter, Calibrators,Precision Bridges and Standard Resistances. Thermal facility has capability to calibrate contact sensors RTD/ thermocouple with precision of as low as 0.16°C & calibrate Non-contact temperature measurement systems Infrared/ Optical pyrometers with precision of as low as 0.6°C, and is equipped with Black Body furnaces, Dry Block furnaces, precision Multimeter, and reference junction.TIPL CALIBRATION LABORATORY has adequate strength of calibration Engineers who are well versed with calibration procedures, and are suitably trained to calculate Measurement Uncertainty as per ISO/IEC 17025:2005.

SR.PARAMETER/

MODE/ METHOD RANGEACCURACY

QUANTITY(Equipment Wise)

(±)

DC VoltageSource/ Direct

Measure/ Direct100nV - 10V100nV - 10V

0.2% to 0.04%0.41% to 0.004%

DC CurrentSource/ Direct

Measure/ Direct5mA - 20mA1mA - 20mA

0.12% to 0.05%0.075% to 0.011%

DC Resistance Source/ DirectMeasure/ Direct

0.001Ω - 100kΩ0MΩ - 1MΩ

1MΩ - 10MΩ

0.05% to 0.057%0.46% to 0.015%0.015% to 0.199%

TemperatureSimulation

SourceRTD - Pt100

T/C - T, J typeT/C - K, N, E typeT/C - R, S, B type

MeasureRTD - Pt100

T/C - T, J typeT/C - K, N, E typeT/C - R, S, B type

No.

-200 - 800ºC 1ºC-100 - 800ºC 1.2ºC-200 - 1300ºC 1.8ºC

0 - 1800ºC 2.7ºC

-200 - 800ºC 1ºC-100 - 800ºC 1.2ºC

1.8ºC0 - 1800ºC 2.7ºC

-200 - 1300ºC

SR.PARAMETER/

MODE/ METHOD RANGEACCURACY

QUANTITY(Equipment Wise) (±)

Temp. Contact

Measure/Comparison 50 - 1400ºC 0.16ºC to 2.2ºC

No.

TypeThermocouple &RTD (Any Type)with and withoutindicator

Temp. Non-Contact TypePortable/ OnlineRadiationThermometer

Measure/Comparison 50 - 1400ºC 0.6ºC to 2.1ºC

Temp. Non-Contact TypeOptical Pyrometer

Measure/Comparison

(Disappearingof Filament)

1000 - 2000ºC 9ºC to 15ºC

1

2

3

1

2

3

3