Hub800_CES_Services v3.0.pdf

Embed Size (px)

Citation preview

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    1/49

    DragonWave Proprietary Data

    Harmony Hub800 R2.6Ethernet and CES procedures

    3/18/2016

    - A -

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    2/49

    DragonWave Proprietary Information 2

    Objective

    The objective of this presentation is to demonstrate how

    to configure Ethernet and CES services.

    Typical Point to point configuration

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    3/49

    DragonWave Proprietary Information 3

    Commissioning Procedure

    Steps:

    1. Create Ethernet services

    2. Create CES service

    3. Configure Clock Synchronization

    4. Monitoring TDM performance

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    4/49

    DragonWave Proprietary Information 4

    Creating Ethernet Service

    1.0 Ethernet Service

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    5/49

    DragonWave Proprietary Information 5

    1.1 Create Ethernet Service

    Select menu Service Management > Ethernet Service >

    Service View and click on Create.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    6/49

    DragonWave Proprietary Information 6

    1.2 Create Ethernet Service

    Enter a Service Name, Service type as E-LAN and

    SVLAN ID as default and in this case is 51,

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    7/49

    DragonWave Proprietary Information 7

    1.3 Create Ethernet Service

    Select the 2 ports to be used for the transport service. In this

    example we selected CESoP P0/1 and port 0/3. Click Next to

    continue.

    Select Next to continue

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    8/49

    DragonWave Proprietary Information 8

    1.4 Create Ethernet Service

    Click Next to continue.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    9/49

    DragonWave Proprietary Information 9

    1.5 Create Ethernet Service

    Leave Service Priority as Priority6.

    Click Next to continue

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    10/49

    DragonWave Proprietary Information 10

    1.6 Create Ethernet Service

    Click Apply to create the Ethernet service.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    11/49

    DragonWave Proprietary Information 11

    1.6 Create Ethernet Service

    When the procedure is complete. Click Close.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    12/49

    DragonWave Proprietary Information 12

    End of Creating an Ethernet Service

    3/18/2016 Pg.

    12

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    13/49

    DragonWave Proprietary Information 13

    2.0 Circuit Emulation Service

    3/18/2016 Pg.

    13

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    14/49

    DragonWave Proprietary Information 14

    2.1 Create CES service

    Select menu Service Management > CES Service >

    Service View and click on Create.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    15/49

    DragonWave Proprietary Information 15

    2.2 Create CES service

    Select Operation mode as Advance.

    Select PW type as CESoP

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    16/49

    DragonWave Proprietary Information 16

    2.3 Create CES service

    Ensure all timeslot are selected. Confirm Port setting.

    Note Remote and Local UDP port setting.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    17/49

    DragonWave Proprietary Information 17

    2.4 Create CES service

    Enter a Customer VLAN (CVLAN) and Select Add.

    Click Next to continue.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    18/49

    DragonWave Proprietary Information 18

    2.5 Create CES service

    Click Add a Traffic profile if none was created.

    Click Next to continue.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    19/49

    DragonWave Proprietary Information 19

    2.6 Create CES service

    Select the Ethernet service that we created in previous

    step. Click Next to continue.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    20/49

    DragonWave Proprietary Information 20

    Create CES service

    Important Notice

    The next step (2.7) is only require when creating the FIRSTCES service.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    21/49

    DragonWave Proprietary Information 21

    2.7.1 Create CES service

    Enter a Name and Source IP address, Net mask and

    Default gateway.

    IP address should not be the same class as your management IP address.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    22/49

    DragonWave Proprietary Information 22

    2.7.2 Create CES service

    Enter Destination IP address. (This is the IP address of the remote CES

    service). Click Next to continue.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    23/49

    DragonWave Proprietary Information 23

    2.8 Create CES service

    Click Apply to create the CES service.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    24/49

    DragonWave Proprietary Information 24

    2.9 Create CES service

    When the procedure is complete. Click Close.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    25/49

    DragonWave Proprietary Information 25

    End of Circuit Emulation Service

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    26/49

    DragonWave Proprietary Information 26

    3.0 Clock Synchronization

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    27/49

    DragonWave Proprietary Information 27

    Clock Synchronization

    Note

    Ethernet port properties PHY master slave selection is

    configured as automatic.

    TDM clock is derived from the Local PDH (E1 or T1).

    If using FPMR, please ensure that SyncE is configure

    correctly.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    28/49

    DragonWave Proprietary Information 28

    3.1 Configure Clock Synchronization (Local)

    Select menu Clock Sync.

    Ensure that the Clock Mode is configured as ssm

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    29/49

    DragonWave Proprietary Information 29

    3.2 Configure Clock Synchronization (Local)

    Select menu Clock Sync > Transmit Source Clock for E1/T1/

    tab.

    Ensure the Output Clock Type is configured as System.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    30/49

    DragonWave Proprietary Information 30

    3.3 Configure Clock Synchronization (Local)

    Select menu Clock Sync > SSM Configuration for

    Ethernet Port tab.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    31/49

    DragonWave Proprietary Information 31

    3.4 Configure Clock Synchronization (Local)

    Enable SSM on the appropriate Ethernet port.

    Highlight row and Click Modify to enable selected port.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    32/49

    DragonWave Proprietary Information 32

    3.5 Configure Clock Synchronization (Local)

    Select menu Clock Sync > General Sync Configuration.

    Click Create to create a sync source.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    33/49

    DragonWave Proprietary Information 33

    3.6 Configure Clock Synchronization (Local)

    On the pop up window configure at shown.

    Ensure the Clock source is the correct PDH (E1/T1).

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    34/49

    DragonWave Proprietary Information 34

    3.7 Configure Clock Synchronization (Local)

    Wait for at least one minute for the Synchronization state

    to change to locked.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    35/49

    DragonWave Proprietary Information 35

    3.8 Configure Clock Synchronization (Remote)

    Select menu Clock Sync.

    Ensure that the Clock Mode is configured as ssm

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    36/49

    DragonWave Proprietary Information 36

    3.9 Configure Clock Synchronization (Remote)

    Select menu Clock Sync > Transmit Source Clock for E1/T1/

    tab.

    Ensure the Output Clock Type is configured as System.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    37/49

    DragonWave Proprietary Information 37

    3.10 Configure Clock Synchronization (Remote)

    Select menu Clock Sync > SSM Configuration for

    Ethernet Port tab.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    38/49

    DragonWave Proprietary Information 38

    3.11 Configure Clock Synchronization (Remote)

    Enable SSM on the appropriate Ethernet port.

    Highlight row and Click Modify to enable selected port.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    39/49

    DragonWave Proprietary Information 39

    3.12 Configure Clock Synchronization (Remote)

    Select menu Clock Sync > General Sync Configuration.

    Click Create to create a sync source.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    40/49

    DragonWave Proprietary Information 40

    3.13 Configure Clock Synchronization (Remote)

    On the pop up window configure at shown. Ensure the Type is ethPort and the Clock source is the appropriate Ethernet port.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    41/49

    DragonWave Proprietary Information 41

    3.14 Configure Clock Synchronization (Remote)

    Wait for at least one minute for the Synchronization state

    to change to locked.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    42/49

    DragonWave Proprietary Information 42

    End of Clock Synchronization

    3/18/2016 Pg.

    42

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    43/49

    DragonWave Proprietary Information 43

    4.0 Monitoring TDM Performance

    3/18/2016 Pg.

    43

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    44/49

    DragonWave Proprietary Information 44

    4.1 Monitoring TDM Performance

    Select menu Performance

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    45/49

    DragonWave Proprietary Information 45

    4.2 Monitoring TDM Performance

    Select PW from the menu tree and Click Enable

    performance monitoring.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    46/49

    DragonWave Proprietary Information 46

    4.3 Monitoring TDM Performance

    To view Performance data. Select PW Performance from

    the menu tree.

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    47/49

    DragonWave Proprietary Information 47

    End of Monitoring TDM Performance

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    48/49

    DragonWave Proprietary Information 48

    Worksheet Ethernet Services

    Local Remote

    Normal Service

    Interfaces

    General Information (Basic Mode)

    Service Name

    Global ID

    Service Type

    Service VLAN ID

    Assign QoS Policy

    Priority

  • 7/26/2019 Hub800_CES_Services v3.0.pdf

    49/49

    DragonWave Proprietary Information 49

    Worksheet CES Services

    Local Remote Notes

    CES Service

    Select TDM Port

    Operation Mode

    Time Slot

    Port

    Remote UDP Port

    Local UDP Port

    CVLAN

    Traffic Profile

    Number of Frames Default is 8

    RTP Header Used Default is Enabled

    Jitter Buffer Default is 4ms

    Name

    Select Ethernet Service

    Basic Setting Initial setting only

    Name

    IP Address

    Net Mask

    Default Gateway Need to point to the router IP or to self

    Config Service

    Name

    Destination IP

    MAC address learning mode Leave as Default