Technical Specification
1330, 60Hz
[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289
Table of Contents
1 Non-clog...................................................................................................................................... 21.1 Product description............................................................................................................. 21.2 Motor rating and performance curves.............................................................................. 4
Table of Contents
1330, 60Hz Technical Specification 1
1 Non-clog1.1 Product description
Usage
A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids. The pump is designed for sustained efficiency over time.
Denomination
Type Non-explosion proofversion
Explosion proofversion
Model variant Installation types
Non-clog 1330.181 1330.090 • H – High head• L – Low head• M – Medium
head• S – Super high
head
• Free-standing• Wet-well
The pump can be used in the following installations:
Free-standing Portable semipermanent, wet well arrangement with hose coupling orflange for connection to the discharge pipeline.
Wet-well Semipermanent, wet well arrangement with the pump installed on twoguide bars. The connection to the discharge is automatic.
Application limits
Feature Description
Liquid temperature Maximum 40°C (104°F)
Depth of immersion Maximum 20 m (65 ft)
pH of the pumped liquid 5.5 – 14
Liquid density Maximum 1100 kg/m3
1 Non-clog
2 1330, 60Hz Technical Specification
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency 60 Hz
Power supply 3-phase
Starting method • Direct on-line• Star-delta• Variable Frequency Drive (VFD)
Number of starts per hour Maximum 15
Code compliance IEC 60034-1
Voltage variation withoutoverheating
±10%, if it does not run continuously at full load
Voltage imbalance betweenphases
Maximum 2%
Stator insulation class F (155°C [311°F])
Cables
Application Type
Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.
Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.
Monitoring equipment
Motor Thermal contacts opening temperature
25-18-2Z, 25-18-6Z, 25-19-4Z 140°C (284°F)
Materials
Table 1: Major parts except mechanical seals
Denomination Material ASTM EN
Major castings Cast iron, gray 30B GJL-200
Pump housing Cast iron, gray 30B GJL-200
Impeller Cast iron, gray 30B GJL-200
Lifting eye bolt Steel electro zinc coated – EN 10084 - C15E
Lifting handle Stainless steel AISI 304 1,4301
Shaft Stainless steel AISI 431 1.4057+QT800
Screws and nuts Stainless steel, A2 AISI 304 1.4301, 1.4306, 1.4307,1.4311
1 Non-clog
1330, 60Hz Technical Specification 3
Denomination Material ASTM EN
O-rings Nitrile rubber (NBR) 70° IRH – –
Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)
– –
Table 2: Mechanical seals
Inner seal Outer seal
Corrosion resistant cemented carbide (WCCR)/ Corrosionresistant cemented carbide (WCCR)
Corrosion resistant cemented carbide (WCCR)/ Corrosionresistant cemented carbide (WCCR)
Surface treatment
Finish
Black or blue two-component high-solid top coating. See internal standard M 0700.00.0004 for standard painting.
Options
• Leakage sensor in the stator housing (FLS)
Accessories
• Installation equipment
Sold in kits• Mechanical accessories such as discharge connections, adapters, and hose
connections• Electrical accessories such as pump controller, control panels, starters, monitoring
relays, and cables
1.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.
Star-delta starting current is 1/3 of Direct on-line starting current.
1 Non-clog
4 1330, 60Hz Technical Specification
H
Q [l/s] / [usgpm]
H [ft] / [m]
2P [hp] / [kW]
0 20 40 60 80 100
0 200 400 600 800 10001200140016001800
0
5
10
15
20
25
30
35
40
45
0
20
40
60
80
100
120
140
160
10
15
20
25
10
20
30
40
H
443
443
444
444
445
445
453
453
454
454
455
455
WS010629A
Table 3: 460 V, 60 Hz, 3–phase
Rated power,kW
Rated power,hp
Curve/Impeller No
Revolutionsper minute,rpm
RatedCurrent, A
Start current,A
Power Factor,cos φ
Installation
27 36 443 1755 42 259 0.89 FS, WW
27 36 453 1755 42 259 0.89 FS, WW
24 32 444 1760 37 259 0.89 FS, WW
24 32 454 1760 37 259 0.89 FS, WW
20 27 445 1765 32 259 0.87 FS, WW
20 27 455 1765 32 259 0.87 FS, WW
• FS= Free-standing• WW=Wet-well
1 Non-clog
1330, 60Hz Technical Specification 5
L
Q [l/s] / [usgpm]
H [ft] / [m]
2P [hp] / [kW]
0 50 100 150 200 250 300
0 1000 2000 3000 4000 5000
0
2
4
6
8
10
12
14
0
10
20
30
40
50
12
14
16
18
20
15
20
25
L
603
603
605
605
606
606
613
613
615
615
616
616
WS010627A
Table 4: 460 V, 60 Hz, 3–phase
Rated power,kW
Rated power,hp
Curve/Impeller No
Revolutionsper minute,rpm
RatedCurrent, A
Start current,A
Power Factor,cos φ
Installation
18.6 25 603 1160 31 174 0.87 FS, WW
18.6 25 613 1160 31 174 0.87 FS, WW
17.2 23 605 1165 29 174 0.86 FS, WW
17.2 23 615 1165 29 174 0.86 FS, WW
14.9 20 606 1170 25 174 0.84 FS, WW
14.9 20 616 1170 25 174 0.84 WW
• FS= Free-standing• WW=Wet-well
1 Non-clog
6 1330, 60Hz Technical Specification
M
Q [l/s] / [usgpm]
H [ft] / [m]
2P [hp] / [kW]
0 20 40 60 80 100 120 140 160
0 500 1000 1500 2000 2500
0
5
10
15
20
25
30
35
0
20
40
60
80
100
120
15
20
25
15
20
25
30
35
40
M
423
423
424
424
426
426
427
427
433
433
434
434
436
436
437
437
WS010628A
Table 5: 460 V, 60 Hz, 3–phase
Rated power,kW
Rated power,hp
Curve/Impeller No
Revolutionsper minute,rpm
RatedCurrent, A
Start current,A
Power Factor,cos φ
Installation
17.2 23 427 1770 28 259 0.84 FS, WW
17.2 23 437 1770 28 259 0.84 FS, WW
27 36 423 1755 42 259 0.89 FS, WW
27 36 433 1755 42 259 0.89 FS, WW
24 32 424 1760 37 259 0.89 FS, WW
24 32 434 1760 37 259 0.89 FS, WW
20 27 426 1765 32 259 0.87 FS, WW
20 27 436 1765 32 259 0.87 FS, WW
• FS= Free-standing• WW=Wet-well
1 Non-clog
1330, 60Hz Technical Specification 7
S
Q [l/s] / [usgpm]
H [ft] / [m]
2P [hp] / [kW]
0 10 20 30 40 50
0 100 200 300 400 500 600 700 800 900
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
20
24
28
25
30
35
40
S
266
266
268
268
276
276
278
278
WS010630A
Table 6: 460 V, 60 Hz, 3–phase
Rated power,kW
Rated power,hp
Curve/Impeller No
Revolutionsper minute,rpm
RatedCurrent, A
Start current,A
Power Factor,cos φ
Installation
28 38 266 3510 42 274 0.93 FS, WW
28 38 276 3510 42 274 0.93 FS, WW
22 30 268 3535 34 273 0.92 FS, WW
22 30 278 3535 34 273 0.92 FS, WW
• FS= Free-standing• WW=Wet-well
1 Non-clog
8 1330, 60Hz Technical Specification
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.
We’re a global team unified in a common purpose: creating advancedtechnology solutions to the world’s water challenges. Developing newtechnologies that will improve the way water is used, conserved, and re-used inthe future is central to our work. Our products and services move, treat, analyze,monitor and return water to the environment, in public utility, industrial,residential and commercial building services settings. Xylem also provides aleading portfolio of smart metering, network technologies and advancedanalytics solutions for water, electric and gas utilities. In more than 150 countries,we have strong, long-standing relationships with customers who know us for ourpowerful combination of leading product brands and applications expertise witha strong focus on developing comprehensive, sustainable solutions.
Visit our Web site for the latest version of this documentand more information
The original instruction is in English. All non-Englishinstructions are translations of the original instruction.
© 2018 Xylem Inc
887515_1.0_en-US_2018-05_TS_1330, 60Hz
[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289