15
Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Embed Size (px)

Citation preview

Page 1: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Projet CMS

CEMESTE19-12-2007

AUG cavernes USC & UXC55

Robert LASSAUSAIE

Page 2: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Une chaîne EUB100/55XAUG NEAR side

102

103

104

105

106

107

108

109

Position des boutons AUG

Page 3: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

201

202

203

204

205

206

207

208

Une chaîne EUB200/55XAUG FAR side

Position des boutons AUG

Page 4: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Position des boutons AUG

301

302

Une chaîne EUB300/55XAUG X0

Page 5: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

18kVEMD210/5E

EMT210/5518000/400V

ERD1/55400V

ERD102/55

~=

Bobine aimant

18kVEMD303/5E

EMT303/5518000/400V

EBD1/55400V

EBD1/55X400V

EBD118

ServicesGénéraux

UXC55

~=

UPS400VEXD2/55

400V

Système Low Voltage

Racks aimantet balconies

SDX5G~EBD1/5E

400V

ESD1/5E400V SECOURS

ESD1/55400V SECOURS

Pompes àdiffusion

VideCRYO

Chauffage cryostat

~~

EOD2/55

CRYOUSC55

UXC55

ServicesGénéraux

USC55

SE5

Alimentation électrique caverne UXC55

Page 6: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

18kVEMD210/5E

EMT210/5518000/400V

ERD1/55400V

ERD102/55

~=

Bobine aimant

18kVEMD303/5E

EMT303/5518000/400V

EBD1/55400V

EBD1/55X400V

EBD118

ServicesGénéraux

UXC55

~=

UPS400VEXD2/55

400V

Système Low Voltage

Racks aimantet balconies

SDX5G~EBD1/5E

400V

ESD1/5E400V SECOURS

ESD1/55400V SECOURS

Pompes àdiffusion

VideCRYO

Chauffage cryostat

~~

EOD2/55

CRYO USC55

UXC55

ServicesGénéraux

USC55

SE5

Ouvert

OuvertDéclenchés

Alimentation électrique caverne UXC55après AUG

Page 7: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

AUG caverne UXC55

Les trois chaînes AUG de la caverne UXC55 ont les mêmes actions

• ACTIONS :– Ouverture EBD118/55 Alimentation SG UXC55– Ouverture EMD210/5E Alim. convertisseur aimant– Déclenchement UPS dans SDX5 Alim. système L.V.

• RESTE SOUS-TENSION– Eclairage de sécurité– Pompes à diffusion– Chauffage cryostat sur réseau secours et UPS– Prises RADMON sur UPS– ?????

Page 8: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

AUG caverne UXC55

• QUESTIONS :– Peut-on laisser sous-tension

• Pompes à diffusion• Chauffage cryostat sur réseau secours

– Est-il normal qu’il y ai des alimentations 400V ‘’réseau’’ sur l’aimant

– Est que d’autres alimentations supérieures à 50V viennent depuis USC55 dans la caverne UXC55 (trackers, heaters, ????)

Page 9: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

211

212

213

214

221235234

233232

242

333332

321311

312

313

314

315

322

Six chaînes AUG dans la caverne USC55

Position des boutons AUG

Page 10: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

EBD1/55X400V

ServicesGénéraux

UXC55

~=

UPS400V

EXD2/55400V

Système Low Voltage

Racks aimantet balconies

SDX5

Pompes à diffusion etChauffage cryostat

USC55

UXC55

ServicesGénéraux

USC55

Bobine aimant

~=

EMT210/5518000/400V

18kVEMD210/5E

ERD1/55400V

ESD1/5E400V SECOURS

G~EBD1/5E400V

ESD1/55400V SECOURS

EOD2/5515mn

~~

SE5

EMT208/5518000/400V

CANALIS S1 & S2Local LASER

18kVEMD208/5E

EXD1/55400V

18kVEMD303/5E

EBD1/55400V

18kVEMD209/5E

EXD2/55400V

CANALIS S4F..HEATER

EMT209/5518000/400V

18kVEMD211/5E

ERD1/55400V

CV: UIAC565Refroidissement

EMT211/5518000/400V

EMT303/5518000/400V

Contrôleaimant

RacksS1.. et S2..

ERD2/55400V

Machine LHC

Alimentation électrique caverne USC55

Page 11: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

EBD1/55X400V

ServicesGénéraux

UXC55

~=

UPS400V

EXD2/55400V

Système Low Voltage

Racks aimantet balconies

SDX5

Pompes à diffusion etChauffage cryostat

USC55

UXC55

ServicesGénéraux

USC55

Bobine aimant

~=

EMT210/5518000/400V

18kVEMD210/5E

ERD1/55400V

ESD1/5E400V SECOURS

G~EBD1/5E400V

ESD1/55400V SECOURS

EOD2/5515mn

~~

SE5

EMT208/5518000/400V

CANALIS S1 & S2Local LASER

18kVEMD208/5E

EXD1/55400V

18kVEMD303/5E

EBD1/55400V

18kVEMD209/5E

EXD2/55400V

CANALIS S4F..HEATER

EMT209/5518000/400V

18kVEMD211/5E

ERD1/55400V

CV: UIAC565Refroidissement

EMT211/5518000/400V

EMT303/5518000/400V

Contrôleaimant

RacksS1.. et S2..

ERD2/55400V

Machine LHC

Alimentation électrique caverne USC55après AUG

OuvertOuvert Ouvert Ouvert Ouvert Ouvert

Déclenchés

Page 12: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Les six chaînes AUG de la caverne USC55 ont les mêmes actions

• ACTIONS :– Ouverture EMD303/5E Alimentation SG USC & UXC55– Ouverture EMD208/5E Alim. CANALIS S1…et S2…– Ouverture EMD209/5E Alim. CANALIS S4F…et Heater– Ouverture EMD210/5E Alim. aimant– Ouverture EMD211/5E Alim. refroidissement– Déclenchement UPS dans SDX5 alim. système L.V.– Déclenchement ESD113/5E réseau ‘’secouru’’ diesel– Déclenchement EBD117/5E Alim. ‘’machine’’ LHC

• RESTE SOUS-TENSION– Eclairage de sécurité– Contrôle de l’aimant sur UPS

AUG caverne USC55

Page 13: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

Décisions prises lors de la réunion CEMESTE

• AUG caverne USC55– Le principe des actions est accepté

• AUG caverne UXC55– Pour éviter qu’il reste des alimentations sous

tension dans la caverne un AUG de UXC55 coupe toutes les alimentations sauf les services généraux de USC55 et l’alimentation de la machine LHC.

Page 14: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

• Les trois chaînes AUG de la caverne UXC55 ont les mêmes actions

• ACTIONS :– Ouverture EMD208/5E Alim. CANALIS S1…et S2…– Ouverture EMD209/5E Alim. CANALIS S4F…et Heater– Ouverture EMD210/5E Alim. aimant– Ouverture EMD211/5E Alim. refroidissement– Déclenchement UPS dans SDX5 alim. système L.V.– Déclenchement ESD113/5E réseau ‘’secouru’’ diesel– Déclenchement EBD118/55 Alimentation SG UXC55

• RESTE SOUS-TENSION– Eclairage de sécurité– Contrôle de l’aimant sur UPS– Services Généraux USC55– Alimentation de la machine LHC

AUG caverne UXC55

Page 15: Projet CMS CEMESTE 19-12-2007 AUG cavernes USC & UXC55 Robert LASSAUSAIE

EBD1/55X400V

ServicesGénéraux

UXC55

~=

UPS400V

EXD2/55400V

Système Low Voltage

Racks aimantet balconies

SDX5

Pompes à diffusion etChauffage cryostat

USC55

UXC55

ServicesGénéraux

USC55

Bobine aimant

~=

EMT210/5518000/400V

18kVEMD210/5E

ERD1/55400V

ESD1/5E400V SECOURS

G~EBD1/5E400V

ESD1/55400V SECOURS

EOD2/5515mn

~~

SE5

EMT208/5518000/400V

CANALIS S1 & S2Local LASER

18kVEMD208/5E

EXD1/55400V

18kVEMD303/5E

EBD1/55400V

18kVEMD209/5E

EXD2/55400V

CANALIS S4F..HEATER

EMT209/5518000/400V

18kVEMD211/5E

ERD1/55400V

CV: UIAC565Refroidissement

EMT211/5518000/400V

EMT303/5518000/400V

Contrôleaimant

RacksS1.. et S2..

ERD2/55400V

Machine LHC

Alimentation électrique caverne USC55après AUG dans UXC55

Ouvert Ouvert Ouvert OuvertDéclenchés

Ouvert