2
voestalpine Sadef nv THE STANDARISED CARPORT www.voestalpine.com/sadef HEADQUARTERS: BELGIUM voestalpine Sadef nv Bruggesteenweg 200 B-8830 Gits T. +32 51/26 12 11 F. +32 51/26 13 01 [email protected] REPRESENTATIVE OFFICES: THE NETHERLANDS W. Witsenplein 4 2596 BK Den Haag, The Netherlands T. + 31 70 324 28 02 F. + 32 51 26 16 13 [email protected] FRANCE 2, Bd Albert 1er 94130 Nogent-s-Marne, France T. +33 1/43 24 60 11 F. +33 1/43 24 60 01 [email protected] GERMANY Franz-Tilgner-Straße 10 50354 Hürth, Germany T. + 49 22 33 20 11 48 F. + 49 22 33 20 28 85 [email protected] SECTION VIEWS All dimensions are in mm FOR OF MIDDLE LOADS FOR HEAVY LOADS

THE STANDARISED - Sadef · Pré-dimensionnement des fondations : Les informations ci -dessous donnent un pré dimensionnement préliminaire. Un ingénieur spécialisé doit dimensionner

Embed Size (px)

Citation preview

voestalpine Sadef nv

THE STANDARISED CARPORT

www.voestalpine.com/sadef

HEADQUARTERS:

BELGIUM

voestalpine Sadef nv

Bruggesteenweg 200

B-8830 Gits

T. +32 51/26 12 11

F. +32 51/26 13 01

[email protected]

REPRESENTATIVE OFFICES:

THE NETHERLANDS

W. Witsenplein 4

2596 BK Den Haag, The Netherlands

T. + 31 70 324 28 02

F. + 32 51 26 16 13

[email protected]

FRANCE

2, Bd Albert 1er

94130 Nogent-s-Marne, France

T. +33 1/43 24 60 11

F. +33 1/43 24 60 01

[email protected]

GERMANY

Franz-Tilgner-Straße 10

50354 Hürth, Germany

T. + 49 22 33 20 11 48

F. + 49 22 33 20 28 85

[email protected]

SECTION VIEWS

All dimensions are in mm

DONNEES TECHNIQUES

www.sadef.com

Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.

Toutes dimensions en mm page 4/6 Version: 6-WN

VUE EN SECTION:

Dans le cas de charges moyennes:

Dans le cas de charges élevées :

DONNEES TECHNIQUES

www.sadef.com

Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.

Toutes dimensions en mm page 4/6 Version: 6-WN

VUE EN SECTION:

Dans le cas de charges moyennes:

Dans le cas de charges élevées :

FOR OF MIDDLE LOADS

FOR HEAVY LOADS

DESIGN » Mono, Double or Multiple Carport » For 1 or 2 parking places » Parking place:

» 3,3 x 5 metres – Mono » 2,5 x 5 (x2) metres – Double » … x 5 meters – Multiple

» Clearance: 2,1 metres » Tilt: 12°

ROOF SYSTEMS » Steel deck » FastSlide (for panel frame heights above 35mm)

FEATURES » Modular in length (Multiple) » For all type of panels » Landscape or portrait panel arrangement

MATERIAL » Foundation base: hot-dipped galvanized » Profiles: Pre galvanized (Z275) » Bolts: hot-dipped galvanized

OPTIONAL » Powder coating

SCOPE OF DELIVERY BY VOESTALPINE SADEF » Frame components and bolts » Assembly instruction

TO BE CARRIED OUT/PROVIDED BY CUSTOMER » Foundations and anchors » Steel deck + Module fixing » Gutter / down comer

BENEFITS » Easily accessible » Quick and easy mounting » Structural design according to Eurocode and its

corresponding national application document

FOR MIDDLE LOADS*To be used in following regions (terrain cat. II) and for a snow load up to Sk= 1.1 except for France Sk= 0.95 » Belgium: >200m AMSL » France: for wind zones 1,2 and 3 and snow zones up to C2 (below 500m) » Netherlands: wind zone 1,2 and 3 » Germany: for wind zones 1 and 2 and snow zone 1,2 and 3 (≤200m AMSL) » UK: entire country (except for Scotland >200m)

FOR HEAVY LOADS*To be used in following regions with heavy snow loads (up to Sk=2.90kN/m2) » Germany: for snow zone 2 (≤750m AMSL), 2a (≤650m AMSL), 3 (≤550m AMSL) » Austria: for snow zone 2* (≤1000m AMSL), 2 (≤800m AMSL), 3 (≤500m AMSL) » France: for snow zone A1 to D (<1250m AMSL), zone E (<800m AMSL)

*Values are indicative and to be checked on project basis

Below information is intended to provide an estimation for preliminary design purposes. A specialized engineer should make final design after further soil investigation. For very weak soil or very fine-grained sands, ask specialized advice.

FOR MIDDLE LOADSFoundation predesign based on: » Moderately good soil » Ø’ - 30° » q = 15 kN/m2 » Concrete C25/30

FOR HEAVY LOADS » A specialized engineer should make the design,

taking into consideration reaction forces delivered by voestalpine Sadef and results of soil investigation.

voestalpine Sadef is not responsible for the design and execution of the foundations. This is a concept design for information only prepared by Establis. A final foundation design will be needed per specific project and can be ordered to the engineering company, e.g. Establis: www.establis.com

TECHNICAL DETAILS APPLICABILITY BY COUNTRY

FOUNDATION PRE-DESIGN

All dimensions are in mmAll dimensions are in mm

FOUNDATION LENGTH L(m)

Flexpark type Middle loads

MONO 2,80

DOUBLE 3,50

MULTIPLE 5,00

DONNEES TECHNIQUES

www.sadef.com

Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.

Toutes dimensions en mm page 5/6 Version: 6-WN

Pré-dimensionnement des fondations : Les informations ci-dessous donnent un pré-dimensionnement préliminaire. Un ingénieur spécialisé doit dimensionner correctement les fondations après une étude du sol. Pour les sols faibles ou sablonneux, faire appel à un spécialiste. Pour charge moyenne :

Etude des pré-fondations basée sur : Sol relativement correct ϕ' - 30° q = 15 kN/m2 Béton C25/30

Pour charges élevées :

Un ingénieur spécialisé doit dimensionner les fondations en prenant en compte

les descentes de charges fournies par voestalpine Sadef

et une étude du sol.

voestalpine Sadef ,n’est pas responsable pour le développement et l’exécution des fondations. Les données définies dans ce document sont à titre informatif. Une définition des fondations est à faire par un bureau d’études spécialisé.

Longueur de fondation L(m)

FLEXPARK TYPE Charge moyenne

MONO 2,80

DOUBLE 3,50

MULTIPLE 5,00

DONNEES TECHNIQUES

www.sadef.com

Le contenu de ce document est confidentiel et est la propriété de voeslpine Sadef nv.

Toutes dimensions en mm page 5/6 Version: 6-WN

Pré-dimensionnement des fondations : Les informations ci-dessous donnent un pré-dimensionnement préliminaire. Un ingénieur spécialisé doit dimensionner correctement les fondations après une étude du sol. Pour les sols faibles ou sablonneux, faire appel à un spécialiste. Pour charge moyenne :

Etude des pré-fondations basée sur : Sol relativement correct ϕ' - 30° q = 15 kN/m2 Béton C25/30

Pour charges élevées :

Un ingénieur spécialisé doit dimensionner les fondations en prenant en compte

les descentes de charges fournies par voestalpine Sadef

et une étude du sol.

voestalpine Sadef ,n’est pas responsable pour le développement et l’exécution des fondations. Les données définies dans ce document sont à titre informatif. Une définition des fondations est à faire par un bureau d’études spécialisé.

Longueur de fondation L(m)

FLEXPARK TYPE Charge moyenne

MONO 2,80

DOUBLE 3,50

MULTIPLE 5,00

MONO

DOUBLE

MULPTIPLE