8/13/2019 Luc 2 - SPC_03
1/18
WinPISA
Setup and Programmingof
Smart Positioning Controller SPC-200
8/13/2019 Luc 2 - SPC_03
2/18
Setup
05.98 / PV-IIP /znk 2
Create a New Project
Select File / New project
Type in a File Name
Confirm with
In the following Dialog
type in a title and an
optional comment;
Confirm with
8/13/2019 Luc 2 - SPC_03
3/18
Setup
05.98 / PV-IIP /znk 3
Configuration of Hardware
Select the Hardware
icon
Right Mouse click the
Hardware icon
At the followingcontext menu ...
8/13/2019 Luc 2 - SPC_03
4/18
Setup
05.98 / PV-IIP /znk 4
Configuration of Hardware
Select
- Insert object /- SPC 200 ...
8/13/2019 Luc 2 - SPC_03
5/18
Setup
05.98 / PV-IIP /znk 5
Configuration of SPC-200
With Online
activated, you canupload the Controller
configuration
For manual configuration,select an empty slot by clicking
8/13/2019 Luc 2 - SPC_03
6/18
Setup
05.98 / PV-IIP /znk 6
Open the
drop down listand select the
according unit
8/13/2019 Luc 2 - SPC_03
7/18
Setup
05.98 / PV-IIP /znk 7
Configuration of Axes
Select the Controller
icon
Right Mouse Click the
Controller icon
On the followingContext Menu ...
8/13/2019 Luc 2 - SPC_03
8/18
Setup
05.98 / PV-IIP /znk 8
Select
- Insert object /- Positioning axis
8/13/2019 Luc 2 - SPC_03
9/18
Setup
05.98 / PV-IIP /znk 9
scroll down the list
with the scroll bar
Select the cylinder by
diameter and stroke range
8/13/2019 Luc 2 - SPC_03
10/18
Setup
05.98 / PV-IIP /znk 10
double click the
Axis icon
8/13/2019 Luc 2 - SPC_03
11/18
Setup
05.98 / PV-IIP /znk 11
Axis Parameter
Designation for drive
stroke length
length of position sensor
8/13/2019 Luc 2 - SPC_03
12/18
Setup
05.98 / PV-IIP /znk 12
Application Parameter
tool load
software limit switches
tolerance
8/13/2019 Luc 2 - SPC_03
13/18
Setup
05.98 / PV-IIP /znk 13
Create a Test Program
Right mouse click
the Software Icon
On the following
context menu select
Insert object ...
8/13/2019 Luc 2 - SPC_03
14/18
Setup
05.98 / PV-IIP /znk 14
Type in a title for
the program
Type in an optional
comment
Confirm with
8/13/2019 Luc 2 - SPC_03
15/18
Setup
05.98 / PV-IIP /znk 15
Editing a Test Program
Type in a first test
program:
N001 G01 X50 FX50
N002 G01 X450 FX50
N003 M30
8/13/2019 Luc 2 - SPC_03
16/18
Setup
05.98 / PV-IIP /znk 16
Syntax Check
Compile Program
Save Program and
Close Window
Speed Buttons:
The Status Bar gives Information about Speed Buttons
8/13/2019 Luc 2 - SPC_03
17/18
Setup
05.98 / PV-IIP /znk 17
Download the Project
Activate the Online Mode:
Online / Online mode
Download the complete Project:
Online / Download / Project
8/13/2019 Luc 2 - SPC_03
18/18
Setup
05.98 / PV-IIP /znk 18
Test the System
Check the input signals:
ENABLE = 24 V (Input 9)STOP = 24 V (Input 7)
Start the system with
START = 0 ---> 1 (Input 8)
Stop the system with
STOP = 0V
NOTE: After first Project Download a 0/1 transit ion
at ENABLE input is required !