64
Users Guide XR200-485

XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

User�s GuideXR200-485

Page 2: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

Copyright © 1997 - 2003 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable.

This information is subject to change without notice.

Silencing an Alarm1. While the alarm bell or siren is sounding, press the

COMMAND key until MENU? NO YES appearsand press the select key under YES. Enter youruser code and press the COMMAND key untilALARM SILENCE appears. Press any top rowselect key. The system silences the alarm bell orsiren.

2. If your system is programmed to send an Abort(alarm cancel) report to the central station, thekeypad displays ALARM CANCELLED.

Page 3: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Command ProcessorTM Panel User's GuideTable of Contents

Introduction .....................................................1About Your Security System ............................... 1Emergency Evacuation Plans .............................. 2The Security Command Keypad ........................... 2Special Security Command Tones ......................... 4Special Security Command Displays ...................... 4Special Wireless Displays .................................. 5Understanding Security System Terms ................... 6General Arming Operation ................................. 8System Arming .............................................. 9

Arming the System ............................................. 9General Disarming Operation ............................ 10Disarming the System from the keypad ................ 11Extending Schedules ....................................... 11

Security Command User Menu ...................... 12Alarm Silence ............................................... 13

Using the Alarm Silence Function ......................... 13Sensor Reset ................................................ 13

Resetting the Sensors ....................................... 13Door Access ................................................. 14

Using the Door Access ...................................... 14Armed Areas Display ....................................... 14

Using the Armed Areas Function .......................... 14

Outputs On Off ............................................ 15Turning the Outputs ON and OFF ......................... 15

Zone Status ................................................. 16Using the Zone Status Function .......................... 16

Bypass Zones ............................................... 17Using the Bypass Zones Function ......................... 17

Zone Monitor ............................................... 17Using the Zone Monitor Function ........................ 18

System Status .............................................. 18Using the System Status Function ........................ 18

System Test ................................................. 19Using the System Test Function ........................... 19

XR200-485B Panic Test .................................... 19User Profiles ................................................ 20

Adding User Profiles ......................................... 20User Profiles Chart ......................................... 21User Codes .................................................. 23Forgive Failure to Exit .................................... 25Ambush Codes .............................................. 25Schedules .................................................... 26Setting the Date and Time ................................ 31

Setting the System�s Date and Time ...................... 31Display Events .............................................. 31Service Request ............................................ 33Fire Drill ..................................................... 33

Page 4: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485B User�s Guide Supplement ........ 34Two Man Rule ............................................... 34System and Panic Zones Test ............................. 34

Using the System Test ....................................... 34Using the Panic Zone Test ................................. 35

Testing your system�s burglary protection .............. 35Bank Safe & Vault .......................................... 35

System Setup ................................................ 36System Setup Record ...................................... 36485B System Setup Record ................................ 36Security Command Keypad Record ....................... 37Area Names and Numbers Record ........................ 37User Codes Record ......................................... 39Schedules Record ........................................... 40Holiday Date Record ....................................... 41Output Relay Record ....................................... 41

Appendix A .................................................... 42About the Display Events Section ........................ 42Arming and Disarming Event Displays .................. 42Zone Event Displays ....................................... 42User Code Change Event Displays ....................... 43Supervisory Event Displays ............................... 43System Monitor Event Displays........................... 44Door Access Event Displays ............................... 44Schedule Change Event Displays ......................... 45Zone Bypass Event Displays ............................... 45

Appendix B .................................................... 46Outputs On/Off Browser .................................. 46Zone Status Browser ....................................... 46Bypass Zones Browser ..................................... 47Zone Monitor Browser ..................................... 47Add User Profiles Browser ................................. 48Delete User Profiles Browser .............................. 48Change User Profiles Browser ............................ 49Add User Codes Browser .................................. 49Delete User Codes Browser ............................... 50Change User Codes Browser .............................. 50Output Groups Browser.................................... 51Entering User Names ...................................... 51

Appendix C .................................................... 52Easy Entry� User's Guide .................................. 52Using the access reader for user menu access ........ 52Pager Direct� User's Guide ............................... 53FA113 User's Guide ........................................ 55Disarming the System ..................................... 55Arming an Area System ................................... 55Disarming an Area System ................................ 55Using the ALERT Buttons .................................. 55Frequently asked questions ............................... 56

Appendix D .................................................... 57Common Keypad Displays ................................. 57Common Keypad Displays Continued .................... 58

Index ............................................................. 59

Page 5: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Introduction 1

About Your Security SystemThe Security Command system has been designed with your safetyand comfort in mind. It uses the latest in computer based technologyto create the most advanced, user friendly security, fire, and accesscontrol system available.

The Security Command system combines ease of use with a simpleto understand Security Command keypad to offer the full range offeatures requested by today�s security system owners.

Use the Security Command system to turn portions of your protectionon or off by pressing a few keys, or have the system turn on or offautomatically by entering a simple schedule. You can add, delete,and change personal user codes at any time or check the status ofprotection devices in the system.

Parts of the SystemThere are two main parts to the Security Command system, theSecurity Command keypad and the keypad User Menu.

Security Command KeypadThis is the device we have placed at certain locations throughout thepremises that allow you to turn the system�s protection on and offusing your personal user code.

Keypad User MenuThe keypad provides a simple User Menu containing all of thefunctions you need to fully operate your system such as changing thetime of day or a personal user code.

A Note About False AlarmsOne of the most important concerns facing the security industrytoday is false alarms. The accidental dispatching of police and fireagencies places others in jeopardy by limiting the response capabilityof those emergency service units. We take this concern seriously andhave spent many hours training our employees to recognize thecauses of false alarms and prevent them from occurring.

As part of our commitment to reducing false alarms, we would liketo encourage you to read this guide thoroughly. All the informationcontained here can help you quickly, and comfortably, learn theoperation of the Security Command system. If you have anyadditional questions, or feel that you need more training, please donot hesitate to contact us.

Test Your System WeeklyIt is recommended that you test the burglary portion of your systemat least once each week. Testing should involve an active test of alldoors, windows, and motion detectors connected to your system. Ifyour system also has fire protection, call the service department tofind out how this portion of your system should be tested.

Refer to the System Test section of this guide for instructions ontesting the burglary portion of your system and refer to the Fire Drillsection for instructions on testing your system fire bells.

Introduction

Page 6: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

2 XR200-485 Introduction

Emergency Evacuation PlansThe National Fire Protection Association recommends that youestablish an emergency evacuation plan to safeguard lives in theevent of a fire or other emergency. Use the following steps as a guide.

Draw a floor plan of your home or businessOn a clean sheet of paper, draw the walls, windows, doors, andstairs. Also draw any obstacles that a person may encounter whileexiting the building such as large furniture or appliances.

Develop escape routesDetermine at least two routes the occupants in each room can taketo safely escape. One route can be the most obvious such as thedoor. Another can be through a window that can be easily opened.If the window is high off the ground, an escape ladder should beprovided.

Draw arrows on the floor plan to show escape routes from each room.

Decide where to meetPrearrange a meeting place outside and away from where emergencypersonnel are likely to be working. A neighbor�s house or across thestreet in the front of the house are good locations. Always performa head count to make sure all occupants safely exited. NEVERENTER A BURNING BUILDING. If the head count shows one or morepersons missing, give this information immediately to the authorities.Never enter a building to look for someone.

Practice your escape plansDevising an escape plan is only the beginning. For the plan to beeffective everyone should practice the escape routes from each room.

Early detectionThe best way to survive a fire or other emergency is to get outearly. The installation of a fire alarm system, with smoke andcarbon monoxide detectors in each room, can greatly decreaseyour risk of loss or injury.

Building Front Building Back

First Floor Second Floor

Fire Escape

Window Ladder

Sample Floor Plan

Page 7: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Introduction 3

The Security Command KeypadYour system may have one or more easy to use Security Commandkeypads (16- or 32-character) that allow you to properly operatethe system. The illustration and descriptions below highlight someof the keypad features:

The Select keysThere are four keys under the display called the Select keys. Thesekeys are one of the features that make your system so easy tooperate by allowing you to make selections by pressing the Selectkey under choice being shown in the display.

For the purposes of this guide, when instructed to press the firstSelect key, press the far left Select key; the second Select key is thesecond from the left; third Select key is second from the right; andthe fourth Select key is the far right key.

Data Entry keysThese keys allow you to enter your user code when arming ordisarming or enter other information into the system.

The Back Arrow keyThe Back Arrow key is used to go back through the keypad displayswhile operating your system. You can press the Back Arrow keyto back up through the list of functions in the User Menu or toerase the last character you entered.

The COMMAND keyThe COMMAND key allows you to advance through the keypaddisplays or User Menu or complete a data entry function.

POWER LEDThis LED remains on steady as long as your system is connected toits AC power supply. Should there be an interruption, the LEDturns off and the system�s backup battery maintains normaloperation for a time so you can contact the service department.

ARMED LEDThis LED is ON steady anytime a burglary protection area is armedand is OFF when ALL areas are disarmed.

2-Button Panic KeysYour keypad may be set up to send a Panic, Emergency, or Firereport to the central station. This function is optional. An iconlabel should appear above the Select keys if this option isprogrammed for your keypad.

To send a panic, press and hold the two Select keys for 2 seconds,until a beep from the keypad is heard.

POWERLED

Lighted display

Select keys

Data Entry keys

COMMAND key

Back Arrow key32-Character Keypad

ARMEDLED

A B C D E F G H I J K L

VWXM N O P Q R S T U

Y Z

COMMAND9 0

1 2 3 4

5 6 7 8

P O W E R ABC PRINTINGFR I 2 : 51 AM

A R M E D

��������������� �

����� ���������� ���������

Page 8: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

4 XR200-485 Introduction

32-Character Keypad User Options MenuPress and hold the Back Arrow and COMMAND keys for about twoseconds. The keypad display shows SET BRIGHTNESS. Use the firstSelect key to lower the display brightness or the fourth Select keyto increase the brightness. Press COMMAND.

At SET TONE, use the first Select key to lower the keypad tone orthe fourth Select key to raise the tone. Press COMMAND.

At SET VOLUME LEVEL, use the first Select key to lower thekeypad volume or the fourth Select key to raise the keypadvolume. Press the Back Arrow key to exit the User Options menu.

Special Security Command TonesYour keypad also contains a small speaker that alerts you aboutevents as they occur on your system. Below are brief descriptionsof the different tones you will hear from the keypad:

Fire Alarm tone: An intermittent sweeping siren that sounds untilthe fire alarm is silenced. From LCD keypads only.

Burglary Alarm tone: A constant siren tone that continues until thealarm is silenced. From LCD keypads only.

Key press tone: A short beep each time you press a key on thekeypad and it�s acknowledged by the system.

Prewarn tone: A continuous pulsed tone that sounds when youopen an entry delay door on a system that is armed (turned on)reminding you to disarm the burglary protection.

Monitor tone: A pulsed tone for one second, one pulse only thatsounds whenever a door or window is opened while you are usingthe zone monitor function from the User Menu. LCD keypadssound a doorbell chime. See Zone Monitor.

Trouble tone: A steady tone indicating a trouble condition on yoursystem. Press a Select key to silence.

Special Security Command DisplaysAs you use your system, you will occasionally see a keypad displaythat asks you to enter a code or that describes a condition on thesystem. Below are some examples of the displays you will see:

ALARMA 24-hour zone (for example fire or panic) or an armed burglaryzone has been tripped. Your system may sound bells or sirens.

TROUBLEThere is a problem with a protection device or system component.This display is accompanied by a description of the problem.

ENTER CODEThe system requires you to enter your user code. User codes can berequired for turning your system on (arming), turning your system off(disarming), and many other functions.

As you enter your user code, the keypad display shows an asterisk(*) in place of each digit pressed. This keeps others from seeingyour user code on the display as it�s entered.

What to do when the trouble tone is soundingYou can silence the trouble tone by pressing any key. Thisonly silences the keypad and does not correct the conditionthat originally caused the trouble.

Page 9: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Introduction 5

TRY AGAIN or INVALID CODEThe user code you have entered is not recognized by the system.Check the user code and try again.

INVALID PROFILEAll user codes have a profile that allow the user to only accesscertain functions. When users attempt functions outside theirauthority, the INVALID PROFILE message displays.

INVALID AREAA user has attempted a door access for an area they are notassigned.

INVALID TIMEA user code assigned to a specific schedule has been entered outsideof the valid schedule. See Schedules and User Codes.

ARMED AREAA user has attempted a door access to an armed area to which theydo not have arming and disarming capability.

FAILED TO EXIT (ANTI-PASS BACK)Anti-pass requires users to properly exit (egress) an area they havepreviously accessed. If they fail to exit through the proper cardreader location they will not be granted access on their nextattempt. If a Failed to Exit message appears, a user assigned theanti-pass back option has attempted to re-enter an area whichthey did not exit properly. The user must exit the area throughthe proper door. If not possible, your system administrator shouldselect the Forgive option in the User Codes menu option.

SYSTEM TROUBLE or SERVICE REQUIREDThere is a problem with one or more of the components in yoursystem. Contact our service department as soon as possible.

SYSTEM BUSYThe Security Command system is performing another task of a higherpriority. This usually only takes a few moments.

Special Wireless DisplaysYour system may use radio transmitters to send alarm and troubleinformation from the protection devices to the panel. Wirelesssystems operate the same as hard-wired and also have a few uniquekeypad displays.

BACK DOOR - LOBAT - (Low Battery) The battery in a radiotransmitter is low. (BACK DOOR is used as an example only.)

BACK DOOR - MISNG - (Missing) The panel is not receiving the radiotransmitter's periodic test report.

WIRELESS - TRBL - (Trouble) Some part of your wireless system isoperating improperly. Test the system to locate the trouble.

Page 10: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

6 XR200-485 Introduction

Understanding Security System TermsThroughout this guide, and in some displays on your keypad, youwill see certain words or phrases that might be unfamiliar. Beloware some terms you will see here and on your keypad display:

AreasAn area is made up of burglary zones that can be armed or disarmedtogether. One area might consist of the office doors and windows.When you arm the office, these zones arm together and sound analarm if opened.

An area also constitutes a place that can be accessed by entering acode at the keypad.

ArmingThis is the term used for turning on the burglary protection in oneor more areas of the system. Your system may require you to entera user code. When armed, the system is able to sound alarm bellsor sirens and, if monitored, send alarm reports to a central stationwhen a burglary zone is tripped.

Fire, panic, and other 24-hour devices are always turned on and donot need to be armed.

FaultIn some cases you may see the keypad display FRONT DOOR �FAULT. This means that there is a problem with the front door,such as the door being open when you are arming the system. Ifyou see a �FAULT display, attempt to correct the problem (in thiscase shut the door). After the zone is in a normal state again, youmay arm the system. You may also bypass the zone and then armthe system.

Central Station MonitoringYour system can also be programmed to automatically send alarm,trouble, and arming and disarming reports to a central station.Operators at the central station can in turn dispatch theappropriate authorities or contact you with the specific eventinformation.

DisarmingThis means turning off one or more areas of the system. Whendisarmed, the system does NOT sound alarms or send alarm reportsto a central station when a burglary zone is faulted.

Door AccessEntry/Exit doors that are used to restrict access to the buildingprovide door access to authorized users. When a user code is enteredat the keypad by entering a code or presenting a card to a reader,the system verifies authority and unlocks the door for a short periodof time. See Easy EntryTM User�s Guide in Appendix C.

Entry or Exit zoneAlmost all systems have one or more doors through which you canenter or exit the premises. These doors are programmed with adelay time to allow you to enter or exit without setting off thealarm.

When you arm the system, activity on this zone is ignored until theprogrammed exit delay time expires. Once that time has expiredand the system is fully armed, opening the door causes the panelto start the entry delay time. During the entry delay time, you mustenter a valid user code to disarm the system or an alarm will occur.

Page 11: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Introduction 7

StatusStatus is a feature that automatically displays the armed ordisarmed status of your system on the Security Command keypads.Alarm or trouble conditions on a zone or a system monitor such asAC or battery trouble can also be displayed. There are two typesof status information available: Armed Status and Status List.

Armed StatusWith Armed Status, the keypad displays the current armed conditionof areas within your security system. For example:

When you arm areas 1 to 4, the keypad shows = 1 2 3 4When you arm areas 1 and 3, the keypad shows = 1 3

Also, for keypads that include an Armed LED, the Armed LED isON steady anytime a burglary protection area is armed and is OFFwhen ALL areas are disarmed.

Status ListThe keypad Status List displays any alarm or trouble condition on azone, and any trouble condition on an internal system monitor. Thesystem monitors include the AC power, battery power, panel boxtamper, printer, and phone lines. If more than one alarm ortrouble condition occurs at the same time, the keypad sequencesthis information on its display.

If the alarm is from a 24-hour zone or a system monitor, it remainsin the Status List until it restores. If one or more armed burglaryzones trip at the same time, the last one to trip remains in theStatus List. This is to ensure that if a burglary has occurred thelast zone tripped remains displayed even if it has been restored.

View Zone StatusTo view the disarmed zones that are in fault, press any Select keywhen the status list is displayed.

ZoneA zone refers to one or more protected openings (doors or windows)or protection devices (motion or glassbreak detectors) groupedtogether under the same zone name and number.

Often, similar devices in the same general area will share the samezone. For example, the windows on the east side of the premises canall be grouped together in a zone named E. WINDOWS.

Instant ZoneInterior protection devices and perimeter devices, such as exteriorwindows, passive infrared detectors, and non entry doors, aretypically not programmed with delay times. If these zones aretripped while the system is armed, an alarm occurs instantly.

24-hour ZoneA 24-hour zone is not turned on or off by arming or disarming yoursystem. Some examples of 24-hour zones are fire zones, paniczones, and temperature control zones.

Page 12: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

8 XR200-485 Arming/Disarming

General Arming OperationYour burglary protection is divided into areas. Each area has acustom name. Areas can be turned on or off independent of otherareas and can have different schedules and authorized users.

After making your arming selection, the keypad displays any zonesthat are currently bypassed. These zones remain bypassed untilthe system is armed and then disarmed. Any 24-hour zones in afaulted condition are also displayed.

Before arming, the system verifies that all doors, windows, andother protection devices to be armed are in normal condition.If everything is okay, the system arms. If there is a problem on oneor more burglary zones, the system cannot arm until the problem iscorrected. If the problem is simply an open door or window, correctthe problem and try arming again.

If the problem cannot be corrected, you can force arm or bypass thezone or wait until the zone can be repaired by a service technician.A force armed zone is ignored by the system until it restores tonormal. A bypassed zone is ignored by the system during the entirearmed period. A zone remains bypassed until the system isdisarmed.

In some cases, you might see the keypad display FRONT DOOR �FAULT. The keypad will then display PRIORITY ZONE which is azone that cannot be bypassed. The problem on the zone must becorrected before the system can be armed.

Armed Message: After all bypassing is completed or zone faultscorrected, the keypad briefly displays ALL SYSTEM ON if all areasin the system are arming and SYSTEM ON if only selected areas arearming. The keypad then displays the exit delay time as it countsdown. When the exit delay time expires, all disarmed zones arearmed.

If your system uses a keyswitch to arm an area, the exit delay timeis NOT shown on the keypad display.

ONE MOMENT . . . Message: If your system is monitored, it maybe programmed to wait for the transmission of an arming report tothe central station before displaying the armed message. (SeeArming Report below.) This is to verify your phone lines are workingproperly. While the system is waiting for the transmission, thedisplay reads ONE MOMENT.... If the report is received, thekeypad displays the armed message. If the report is not received,the keypad displays LOCAL ALARM ONLY before displaying thearmed message.

Arming Report: Your system can be programmed to send armingor zone bypassing reports to a central station. This feature isoptional and can be programmed for you at any time.

Page 13: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Arming/Disarming 9

System ArmingArea Assignment: Your security system has been set up intoseparate areas. The number of areas and their names are listedin the back of this guide.

Arming or Disarming: You can arm and disarm all areas at one timeor each area individually. You can only arm or disarm areasauthorized for your user code.

Arm all or Selective Arming: After entering your user code, thesystem allows you to arm either all of the areas to which you haveaccess or one or more selected areas. If you choose to arm all areas,the system begins verifying that all zones in those areas are in a goodcondition. If you choose to arm selected areas, the system promptsyou to choose the areas you want to arm.

Arming the System1. Press the COMMAND key until ARM DISARM is displayed.2. Select ARM to arm the system.3. Enter your user code if required. The display reads

ALL? NO YES.4. Select NO to arm only selected areas. Go to step 5. Select YES

to arm all areas authorized for your user code. Go to step 6.5. If you selected NO in step 4, the display begins to list each area

to which you have access followed by NO YES.Example: OFFICE NO YES5a. Select YES for each area you want to arm.5b. Select NO for each area you do not want to arm.

Note: You can also just press the area numbers you want to armwhile at the ALL? NO YES display. This changes the displayto AREAS: . The area numbers you select appear in thedisplay. For example: AREAS: 2 4 . Press COMMAND whendone.

6. The system displays any bypassed zones or faulted 24-hour orPriority zones. A faulted Priority zone cannot be armed.

7. At this point you can force arm or bypass any faulted zones. Azone that is force armed will be restored into the system if it laterreturns to normal. A zone that is bypassed will remain bypasseduntil the system is disarmed. See steps 7a through 7d.

7a. If a problem exists on a zone, the zone name and problemis shown followed by: OKAY BYPASS STOP.

7b. Select OKAY to force arm the faulted zone.

7c. Select BYPASS to bypass all faulted zones being displayed.

Note: 24-hour zones cannot be bypassed.

7d. Select STOP to stop the system from arming. Correct thezone problem(s) and return to step 1.

Your system may be programmed to require a user code thathas authorization to force arm or bypass a faulted zone. Thesystem will ask for a user code to be entered.

8. The display reads SYSTEM ON if at least one area in the systemis armed, and ALL SYSTEM ON if all areas in the system arearmed.

9. The keypad then displays the exit time in seconds and countsdown the remaining time: EXIT : ## (## = seconds remaining).The exit zones arm when the delay time expires.

Page 14: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

10 XR200-485 Arming/Disarming

General Disarming OperationWhile the system is armed, you can only enter the premisesthrough an entry/exit delay door without causing an alarm. Afteropening the door, the Security Command keypad sounds aprewarn tone to remind you to disarm the system. (See DoorAccess Disarming below.) You must disarm the system before theentry delay time expires or an alarm on the door zone will occur.

During the entry delay time, the keypad displays ENTER CODE:.Enter your code to disarm the system. Only those areas assignedto your code will disarm.

When you present your card to an outside reader to gain accessand your code has authority to disarm, those areas assigned to thedoor which match areas assigned to your code will automaticallydisarm. Enter code is not displayed.

Schedules: If you have programmed schedules for your system anda code is entered outside of a schedule and that code does nothave authorization to disarm outside of schedules, the keypaddisplays INVALID TIME. This lets the users know that they aredisarming outside of their authorized time. If your system ismonitored, an Unauthorized Entry report is sent to the centralstation.

All or Selective Disarming: After entering your user code, thesystem allows you to disarm either all of the areas to which youhave access or just selected areas. If you choose to disarm allareas, the system automatically disarms them. If you choose todisarm selected areas, the area names will be displayed on thekeypad.

Alarm Display: After disarming, the keypad displays any zones thattripped or any transmission problems that occurred during thearmed period. All burglary zones are then disarmed and anybypassed zones are automatically reset.

Disarmed Message: The keypad displays ALL SYSTEM OFF after thesystem disarms.

Central Station Report: A report of the system disarming can betransmitted to the central station. This is optional and can beprogrammed for you at any time.

Door Access Disarming: Your system may be programmed to allowdisarming of areas when a card is presented to a door accessreader located outside of the building. Simply present your cardto the reader and after the card�s code is validated for theappropriate authority, a door access is granted and your matchingareas are automatically disarmed. See the Easy EntryTM User�sGuide in Appendix C.

Page 15: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Arming/Disarming 11

Disarming the System from the keypad1. Press the COMMAND key until ARM DISARM is displayed.

During entry delay this process starts at step 3.2. Select DISARM to disarm areas.3. The keypad displays ENTER CODE: . Enter your user code and

press COMMAND. The keypad displays ALL? NO YES.4. Select YES to disarm all areas authorized for your user code.

Select NO to disarm only certain areas individually. Thekeypad then displays the name of each area authorized foryour user code followed by the NO YES display.Choose YES to disarm the area displayed.Choose NO to not disarm and to display the next area.Note: You can also just press the area numbers you want todisarm while at the ALL? NO YES display. This changes thedisplay to AREAS: . The area numbers you select appear in thedisplay. For example: AREAS: 2 4 . Press COMMAND whendone.

5. After all areas have been displayed, any alarms or communicationproblems that occurred during the armed period are displayed.

6. If all areas have been disarmed, the keypad next displays ALLSYSTEM OFF.

Extending SchedulesDepending on your system�s programming, when the scheduleexpires (the ON time) you can extend the schedule to a later time.The keypad buzzer sounds and the keypad displays �area name�and LATE or CLOSING TIME!. This reminds users still on thepremises to arm the system or extend the schedule.

To extend the system�s schedule:

1. Press a Select key. The keypad will display ENTER CODE:-.2. Enter your code and press COMMAND or present your access

card to a valid reader. The system�s schedule is automaticallyextended one hour.

3. The keypad then displays -: AM PM. You can enter a timeto extend the schedule for greater than one hour. Press AMor PM.Note: If the system is not armed by the scheduled closing time,a Late to Close report is sent to the central station. If theschedule is extended, a Schedule Change report is sent to thecentral station.

For information about extending a schedule before the scheduledclosing time has been reached, see Extending Schedules (EXT) inthe User Menu portion of this guide.

Page 16: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

12 XR200-485 User Menu

Security Command User MenuMany of the features of your system have been put into a UserMenu that you can access from any Security Command keypad.The menu requires you to enter your user code and then it onlyshows those functions to which you have access.

To access the User Menu:

1. Press the COMMAND key until MENU? NO YES displays.

2. Select YES. The keypad displays ENTER CODE: �. Enter youruser code and press COMMAND. You can now scroll downthrough the list of system features available to you.

User Menu OptionsThe list below shows the User Menu options in order:

Menu Option Description

ALARM SILENCE Silences an alarm bell or siren.

SENSOR RESET Resets smoke or glassbreak detectors thathave latched due to an alarm condition.

DOOR ACCESS Momentarily opens the keypad�s door lockrelay.

ARMED AREAS Displays the name of any areas in thesystem that are currently in the armedstate.

OUTPUTS ON/OFF Allows you to turn on or off any of theoutputs described in the System Setupsection of this guide.

ZONE STATUS Allows you to see if a zone is either armed,bypassed, in alarm, open, or shorted.

BYPASS ZONES Allows you to Bypass a zone or reset analready bypassed zone.

ZONE MONITOR Allows you to add or remove a zone from themonitor mode.

SYSTEM STATUS Displays the current condition of the system'sAC power, backup battery, and panel tamper(optional).

SYSTEM TEST Tests the system's siren, communication tothe central station, and backup battery.

USER PROFILES Allows you to change user profiles.

USER CODES Allows you to add, delete, or change usercodes.

SCHEDULES Allows you to add, remove, or changesystem schedules.

TIME Allows you change the Day, Date, or Timethat is currently in the system.

DISPLAY EVENTS Allows you to view or print the last 1,000door accesses or 200 system events thatoccurred on your system.

SERVICE REQUEST Allows you to send a message to the CentralStation requesting service on the alarmsystem.

FIRE DRILL Allows you to test the system�s fire bells.

User Menu

Page 17: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 13

Alarm SilenceSilences the alarm bells or sirens during an alarm.

Alarm Silence allows you to turn off the alarm bells and sirensconnected to your system during an alarm. Using Alarm Silence doesNOT stop an alarm report from being sent to the central stationand does not reset any alarmed devices. Use the Sensor Resetfunction to reset devices such as smoke detectors that havelatched in alarm.

Note: You can also silence an alarm by entering your user code andpressing COMMAND or by presenting your card to a reader whilethe Status List is displaying. Matching areas assigned to your codeare disarmed and a door access occurs.

Using the Alarm Silence Function1. Access the User Menu.2. The keypad displays ALARM SILENCE?.3. Press any Select key to silence the bells and exit the User

Menu.

Sensor ResetResets smoke or glassbreak detectors. Also clears Fire/Supervisoryalarm and trouble displays.

Sensor Reset is used to reset smoke and glassbreak detectors afterthey have been tripped. Once these detectors have tripped, theymust be reset before they can detect any additional alarmconditions. When Sensor Reset is selected, power to thedetectors is temporarily removed by the system allowing them toreset.

Make sure all smoke is cleared from around the area of the smokedetectors before performing a Sensor Reset to prevent the alarmfrom occurring again.

Resetting the Sensors1. Access the User Menu.2. Press COMMAND until SENSOR RESET displays.3. The keypad displays SENSORS OFF for five seconds followed by

SENSORS ON.4. The keypad automatically exits the User Menu.

Page 18: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

14 XR200-485 User Menu

Door AccessOperates an electric door strike from the keypad.

Door Access is used to operate a door strike relay that is built intosome Security Command keypads. Power for the door strike isconnected to the keypad relay and can be interrupted by using theDoor Access function.

Door Access also operates by simply entering your user code andpressing COMMAND while the Status List is displaying. See EasyEntryTM User�s Guide in Appendix C. If you are using a 793 keypad thathas a built-in card reader, you may simply present your card to begiven Door Access.

A report of this entry can be sent to your central station. Thisreport is optional and can be programmed for you at any time.

Using the Door Access1. Access the User Menu.2. Press COMMAND until DOOR ACCESS? displays.3. Press any Select key. The door strike relay turns on

momentarily.4. The keypad returns to the Status List display.

Armed Areas DisplayDisplays all armed area names in the system.

The Armed Areas display lists all of the names of the armed areasin your system at the Security Command keypads.

Using the Armed Areas Function1. Access the User Menu.2. Press COMMAND until ARMED AREAS? displays.3. Press any Select key. The keypad displays the first armed area

name. To scroll through the list of armed area names, pressthe COMMAND key.

4. If there are no armed areas, the keypad displays NONE.

Page 19: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 15

Outputs On OffAllows you to manually turn the system or door access relayoutputs ON and OFF.

This function is used to individually turn your system�s relay andaccess door outputs ON and OFF. Your system may use these outputsto control door access, interior and exterior lighting, heating, airconditioning, or other appliances.

The names and numbers of the relays connected to your systemare located in the System Setup section of this guide.

Outputs can be turned ON or OFF regardless of the output settingsin Schedules.

Your system may be programmed to require that your user codeprofile have access to areas assigned to the keypad. INVALID AREAis displayed when your user code does not have access to thekeypad�s areas and the output does not turn on.

Under certain conditions, some outputs cannot be turned on.If you select a restricted output, the keypad displaysCANNOT TURN ON.

Turning the Outputs ON and OFF1. Access the User Menu.2. Press COMMAND until OUTPUTS ON/OFF? displays.3. Press any Select key to display OUTPUTS DOOR.4. Select the type of output you want to turn ON or OFF by

pressing the Select key under OUTPUTS or DOOR.5. Enter the output number you want to turn ON or OFF. The

output number will appear in the display. The range for outputsis 1-10, 100-199, 200-299. The range for door is 1-16.

6. With the output number displayed, press the Select key underON or OFF. The output is then turned ON or OFF depending onyour Selection, and remains in that state until you change it.The keypad displays the first 12 characters of the output ordoor name followed by either ON or OFF for four seconds toprovide visual verification of the action. Press the COMMANDkey to end the four second display.

7. The system automatically returns to the output or doorprompt and a new output can be selected to turn ON or OFF.Refer back to step 4.

8. Press the Back Arrow key to exit the User Menu.

☞☞☞☞☞ Browser FeatureIf you are unsure of the output number, refer toAppendix B at the back of this guide for a diagram showingyou how to use the built-in Outputs ON/OFF browser.

Page 20: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

16 XR200-485 User Menu

7. Press NBR and ZONE NO: - will be displayed.8. At the ZONE NO: - prompt, enter the zone number you want

to check and press COMMAND. The zone number and nameis displayed followed by its status. For example, a zone statusfor zone 1 might be BACK DOOR - OKAY.

Below is a list of the zone status displays:-OKAY = the zone is in a normal condition-BYPAS = the zone is bypassed-BAD = the zone is in a bad or faulted condition

9. After displaying the zone status, ZONE: - returns for you toenter another zone number.

☞☞☞☞☞ Browser FeatureIf you are unsure of the zone number or description, referto Appendix B at the back of this guide for a diagramshowing you how to use the built-in Zone Status browser.

Zone StatusDisplays a list of armed, bypassed, or alarmed zones. Also allows youto check the status of individual zones. Zone Status can be used togive you a list of zones by category or display the current status ofan individual zone number. The four categories are:

� Armed Zones - zones that are currently armed.� Bypassed Zones - zones that are currently bypassed.� Alarmed Zones - zones that have gone into alarm during the

current or previous armed period.� Number - enter the number of any zone to check its status.

Using the Zone Status Function1. Access the User Menu.2. Press COMMAND until ZONE STATUS? displays.3. Press any Select key to display ARM BYPS ALR NBR.4. Select ARM for a list of zones that are currently armed. You

can scroll through the list by pressing the COMMAND key.5. Select BYPS for a list of zones that are currently bypassed.6. Select ALR for a list of zones that have gone into alarm during

the current or previous armed period.

Page 21: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 17

Bypass ZonesAllows you to bypass a zone prior to arming.

Bypassing is usually done when a zone cannot be restored tonormal. A significant benefit of bypassing a zone is to allow a zonein a faulted or bad condition to be bypassed so that arming canoccur. The faulted zone can be serviced the next day.

A zone can be bypassed only while it is disarmed. Fire, panic,emergency, and supervisory type zones are always armed, so theycan never be manually bypassed.

Bypass Zones can also be used to reset a zone that has been bypassedand restore it back into the system.

When Bypass Zones is selected, a report can be transmitted to yourcentral station.

Using the Bypass Zones Function1. Access the User Menu.2. Press COMMAND until BYPASS ZONES? displays.3. Press any Select key. The keypad displays

ZONE: - RST BYPS.4. To Bypass a zone, enter the zone number and select BYPS.

The zone number automatically disappears and a new zonenumber can be entered. Refer back to step 3.

5. To Reset a zone, enter the zone number and select RST.

☞☞☞☞☞ Browser FeatureIf you are unsure of the zone number or description, referto Appendix B at the back of this guide for a diagramshowing you how to use the built-in Bypass Zones browser.

Zone MonitorAllows the system to monitor selected disarmed zones (doors,windows, or motion detectors) and display their name at the keypadas they are faulted. This feature could be used to monitor an accessdoor.

Zone Monitor works with any disarmed zone and will also sound thekeypad monitor tone when the zone faults. The zone name isdisplayed at all keypads in your system.

You can place any combination of disarmed zones in Zone Monitorbut only the most recent zone faulted is displayed. The displayedzone name clears automatically after a short time or when the zoneis armed.

Using Zone Monitor as part of your weekly system test: Afterusing the System Test function, place all zones in Zone Monitor.Starting at the front door, go around and open and then closeeach door and window. You should hear the keypad beep eachtime. The keypad will also display the name of each zone as itsdevice is opened.

Once all protected doors and windows have been tested, walk infront of each motion detector. The keypad should beep toconfirm their operation. If at any time during your weekly testinga device does not cause the keypad to beep, call the servicedepartment for assistance.

Page 22: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

18 XR200-485 User Menu

Using the Zone Monitor Function1. Access the User Menu.2. Press COMMAND until ZONE MONITOR? displays.

3. Press any Select key. The keypad displays ALL NBR.

4. Select ALL to place all disarmed zones into Zone Monitor.

4a. The keypad displays ALL? ADD RMV.4b. Select ADD to add all disarmed zones to Zone Monitor.

4c. Select RMV to remove all disarmed zones.

5. Select NBR to enter a specific zone number for zone monitor.

6. If NBR is selected, the keypad displays ZONE: - ADD RMV.

6a. Enter any zone number and select ADD to add this zone.

6b. Enter any zone number and select RMV to remove thiszone.

7. The zone number automatically disappears and a new zonenumber can then be entered in step 6a or 6b.

☞ ☞ ☞ ☞ ☞ Browser FeatureIf you are unsure of the zone number or description, referto Appendix B at the back of this guide for a diagramshowing you how to use the built-in Zone Monitor browser.

System StatusDisplays the current condition of internal system hardware.

System Status displays the condition of the panel's AC power, batterypower, and optional panel tamper. When System Status is selected,each monitor is displayed followed by OKAY or TRBL (Trouble) toindicate the current condition.

Using the System Status Function1. Access the User Menu.2. Press COMMAND until SYSTEM STATUS? displays.3. Press any Select key. The display starts listing each system

monitor and status.For example: AC POWER - OKAY

Below are the System Monitor displays:

Keypad Display What it monitorsAC POWER = AC powerBATTERY = Battery powerTAMPER = Panel box tamper

These are followed by either OKAY or TRBL (trouble).

If TRBL is displayed, call the service department for assistance.

4. The system then displays its firmware version (for example,VER_201_9/15/99), the panel model (MODEL XR200-485),and then exits the User Menu.

Page 23: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 19

System TestSystem Test is used to test the battery, alarm bell or siren, andcommunication to a central station. The System Test functionbegins automatically as soon as you select it.

Using the System Test Function1. Access the User Menu.2. Press COMMAND until SYSTEM TEST? displays.3. Press any Select key. The system test begins automatically

and the keypad displays the following messages in this order:1) BELL SOUNDING during a two second bell test2) BATTERY - OKAY or BATTERY - TRBL to indicate the

condition of the battery* 3) TRANSMIT TEST and ATTEMPT NO : 1 during the

transmit test4) TRANSMIT OKAY or TRANSMIT FAILED to show the

results of the transmit test5) TEST END to indicate the System Test is complete.6) You can end the transmit test by pressing the Back Arrow

key.* The transmit test does not operate on local systems.

Testing your system�s burglary protection: The System Testfunction should be a part of your weekly testing and should befollowed by placing the interior and perimeter burglarydevices in Zone Monitor mode. This allows you to open andthen close each protected door and window while listeningfor the keypad to beep confirming its operation. See ZoneMonitor.

XR200-485B Panic TestYour system may be a Model XR200-485B which includes a panicbutton zone test. See the XR200-485B User�s Guide Supplementsection in the back of this guide.

Page 24: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

20 XR200-485 User Menu

User ProfilesThis option allows you to add, delete, or change User Profiles. Aprofile defines the authority of each user code in the system. Thereare several characteristics associated with each User Profile thatdefine its authority within the system.

Profile Number - Each profile may be assigned a unique numberfrom 1 to 99. The Profile Number is the default Profile Name.

Profile Name - Each profile may be assigned a 16 character name.The Profile Number is used as the Default name.

Area Number - Each profile may be assigned specific areas of theburglary part of the system for arming and disarming. When profiles1 to 98 are created, NO areas are assigned by default and the defaultfor profile 99 is ALL areas assigned. Profile 99 is already added tothe system by the factory.

Access Area Number - Each profile may be assigned door accessarea assignments. Default for profile 1 to 98 is NO areas assignedand default for profile 99 is ALL areas assigned. Profile 99 is alreadyadded to the system by the factory.

Output Group Assignment - Each profile may be assigned an outputgroup number from 1 to 10. Default for profile 1 to 98 is NO outputgroup assigned and default for profile 99 is output group ten. Yoursystem may by programmed to turn on an output group at certainkeypads when a door access occurs.

User Menu Assignments - Each user profile may have any of themenus assigned to it as shown in the Profile table on page 21. Forexplanations of User Menu Assignments, read the descriptions in thepages that follow. The Profile table lists the user menu profileassignments and the system functions users are allowed to accessbased on the profile numbers assigned to their codes. The settingslisted in the table are default values and any of the profiles can bechanged.

When adding or changing a profile, only selections that yourcode has authority to modify are shown.

Always make sure that at least one administrator code in yoursystem has a profile with all authorities.

Adding User Profiles1. Access the User Menu.2. Press COMMAND until USER PROFILES? displays.3. Press any Select key. The keypad displays ADD DEL CHG.4. Press the first Select key, under ADD, to add a new user

profile.5. At the PROFILE NO: - prompt, enter an unused profile number

and press COMMAND. The display changes to PROFILE NAME.6. Press any Select key and the display changes to -. Enter a profile

name of up to 16 characters. After the name is entered, pressCOMMAND. See Entering Names in Appendix B.

7. At the AREAS: prompt, enter the area numbers (1-8) for armingand disarming assigned to this profile.

8. The keypad displays ACCESS: . Enter the area numbers(1-8) assignment to allow door access for this profile. Press theCOMMAND key.

9. The keypad displays OUTPUT GROUP: -. Enter the number (1-10) for the Output Group assigned to this profile. Press theCOMMAND key.

10. The keypad displays each of the menus as shown in the ProfileTable on the following page for you to enable for this profilenumber. Select YES or NO and press the COMMAND key toadvance to the next menu Selection.

11. When you have completed Selecting all User Profile menuassignments, the keypad displays PROFILE ## ADDED messagefor 4 seconds.

Page 25: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 21

User Profiles Chart

seliforP

rebmuNuneM egelivirP 1 2 3 4 5 6 7 8 9 01 89-11 99

SID/MRA ON SEY mrasiDdnamrA oN seY seY seY seY seY seY seY seY oN oN seY

CNLSMLA ON SEY ecneliSmralA oN seY seY seY seY seY seY seY seY oN oN seY

TSRRSNS ON SEY teseRrosneS seY seY seY seY seY seY seY seY seY oN oN seY

SCAROOD ON SEY sseccArooD seY seY seY seY seY seY seY seY seY seY oN seY

AERAMRA ON SEY saerAdemrA seY seY seY seY seY seY seY seY seY oN oN seY

STUPTUO ON SEY FFO/NOstuptuO oN oN oN oN seY seY seY seY seY oN oN seY

STATSNZ ON SEY sutatSenoZ seY seY seY seY seY seY seY seY seY oN oN seY

NZSAPYB ON SEY senoZssapyB oN oN oN oN oN seY seY seY seY oN oN seY

NOMENOZ ON SEY rotinoMenoZ oN oN oN seY seY seY seY seY seY oN oN seY

TATSSYS ON SEY sutatSmetsyS seY seY seY seY seY seY seY seY seY oN oN seY

TSETSYS ON SEY tseTmetsyS oN oN oN seY seY oN seY seY seY oN oN seY

SELIFORP ON SEY seliforPresU oN oN oN oN oN oN oN oN seY oN oN seY

EDOCRSU ON SEY sedoCresU oN oN oN oN oN oN oN oN seY oN oN seY

SLUDEHCS ON SEY seludehcS oN oN oN oN oN oN seY seY seY oN oN seY

EMIT ON SEY emiT oN oN oN oN oN oN oN seY seY oN oN seY

TNVESID ON SEY stnevEyalpsiD seY seY seY seY seY seY seY seY seY oN oN seY

QERVRES ON SEY tseuqeRecivreS oN oN oN oN oN oN oN seY seY oN oN seY

LIRDERIF ON SEY llirDeriF oN oN oN oN oN oN oN seY seY oN oN seY

DNETXE ON SEY seludehcSdednetxE oN oN oN oN oN seY seY seY seY oN oN seY

EDOCPMET ON SEY edoCresUyraropmeT oN oN oN oN oN oN oN oN oN oN oN oN

SSAPITNA ON SEY kcaBssapitnA oN oN oN oN oN oN oN oN oN oN oN oN

4321:WOLA __ YNA sseccAemiT/tfihS:wolA 4321 4321 ynA ynA ynA ynA ynA ynA ynA ynA ynA ynA

Page 26: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

22 XR200-485 User Menu

Deleting User Profiles1. Access the User Menu.2. Press COMMAND until USER PROFILES? displays.3. Press any Select key. The keypad displays ADD DEL CHG.4. Press the second Select key, under DEL, to delete a user

profile.5. At the PROFILE NO: - prompt, enter a profile number and press

COMMAND. The display changes to DELTD.Note: User codes assigned to deleted profiles will not function.

Changing User Profiles1. Access the User Menu.2. Press COMMAND until USER PROFILES? displays.3. Press any Select key. The keypad displays ADD DEL CHG.4. Press the far right Select key, under CHG.4. At the PROFILE NO: - prompt, enter a profile number and press

COMMAND. The display changes to PROFILE NAME.5. Press any Select key and the display changes to -. Enter a profile

name of up to 16 characters. The default Profile Name usesthe Profile Number. After the name is entered, pressCOMMAND.

6. At the AREAS: prompt, enter the area numbers (1-8) for armingand disarming assigned to this profile.

7. The keypad displays ACCESS: . Enter the area numbers(1-8) assignment to allow door access for this profile. Press theCOMMAND key.

8. The keypad displays OUTPUT GROUP: -. Enter the number(1 through 10) for the Output Group assigned to this profile.Press the COMMAND key.

9. The keypad displays each of the menus as shown in the ProfileTable for you to enable for this profile number. Select YES orNO and press the COMMAND key to advance to the next menuSelection.

10. When you have completed Selecting all User Profile menuassignments as shown in the Profile table, the keypad displaysPROFILE CHNGD message for 4 seconds, indicating the profileis changed.

TEMP CODEWhen YES is selected for this menu option, and when this profileis assigned to a user code (see next section), the keypad willdisplay TEMP DAYS: . Enter the number of days (1 to 250) thata temporary User Code can operate. Default is 7 days. Tempusers are deleted from the system at 12:00 AM on the last day.

ALOW: 1 2 3 4 ANYThis menu option defines the time schedules that the UserCode will operate for door access and disarming. Selecting1, 2, 3, and/or 4 indicates operation during the S1-S4 shiftschedules. Selecting ANY (fourth Select key) from the menuindicates that the code will operate any time, regardless ofschedules. All shift schedules may be selected for one user.Menu access is not affected by this option.An UNAUTHORIZED ENTRY message is sent to the centralstation if disarming occurs outside the open/close schedule forany of the areas.

☞ ☞ ☞ ☞ ☞ Browser FeatureRefer to Appendix B at the back of this guide for a diagramshowing you how to use the Output Group browser and theProfile browsers.

Page 27: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 23

5. At the USER NUMBER: - prompt, enter a user number and pressCOMMAND. The display changes to CODE NO: - .

6. Enter a user code of 3 to 5 digits and press COMMAND. Theuser enters this number to arm, disarm, etc. If using accesscards, present the card instead of entering a code. After thecode is entered the keypad displays USER NUMBER ### as theuser name.

7. A 16-character name may be entered to identify the user.Press any top row key to clear the current name. You maythen enter the new name. After the name is entered pressCOMMAND. See Entering Names in Appendix B.

8. The display changes to PROFILE NO: -. Select the profilenumber to assign a set of authorized functions to the usercode as outlined in the Profile Table on the previous page.

9. At the PROFILE NO: - display, enter a profile number from1 to 99, and press COMMAND. The displays showsUSER # ADDED.If BAT (Batch) has been chosen in step 4 instead of ADD, thenext available user number will be automatically selected andsteps 6 and 7 only will be repeated. The User Profileassignment will be automatically selected for the next userbased on the previous user entered. This batch entry methodspeeds up user entry in large systems.

☞ ☞ ☞ ☞ ☞ Browser FeatureRefer to Appendix B at the back of this guide for adiagram showing you how to use the User ProfilesChange browser.

User CodesThis option allows you to add, delete, or change a user code. Youmay also assign specific User Profiles to individual users.

125 34812 John Smith 7

User Number - Every user is numbered. This number identifies theuser to the system and is transmitted to the central station when theuser arms or disarms areas.

User Code - Each user also has a 3 to 5 digit number to enter intothe Security Command keypad when arming or disarming thesystem. Note: A User Code cannot begin with zero and 3-digitcodes cannot begin with 98.

User Names - Each code may also be programmed with the user�sname. Up to 16 characters may be entered.

User Profile - The user is also assigned a Profile (1 to 99) by theperson administrating the system that determines the areas andfunctions the user can access.

Adding User Codes1. Access the User Menu.2. Press COMMAND until USER CODES? displays.3. Press any Select key. The keypad displays

ADD DEL CHG BAT.4. Press the Select key under ADD or BAT (Batch) to add a new

user code.

User Number User Code User Name User Profile

Page 28: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

24 XR200-485 User Menu

Changing User Codes1. Access the User Menu.2. Press the COMMAND key until USER CODES? displays.3. Press any Select key. The keypad displays

ADD DEL CHG BAT.4. Press the third Select key, under CHG, to change a user code.5. At the USER NUMBER: - prompt, enter the user number to

change and press COMMAND.Refer to the System Setup section for the number of user codesavailable for your system.

6. The display changes to CODE NO: * * * * *. Press a Select keyand enter the new user code. Press COMMAND.

7. The display then shows the current user name. Press any toprow key to clear. See Entering Names in Appendix B to entera new name.Note: Changing a user code does not change the user number.

8. The display changes to PROFILE NO: -. Select the profilenumber to assign a set of authorized functions to the usercode as outlined in the Profile Table on page 11.

9. After entering the profile number, the keypad displaysUSER # CHANGED for 5 seconds followed byUSER NUMBER: -. This display allows you to enter another usernumber to change. Press the Back Arrow key twice to exit theUser Menu.

☞ ☞ ☞ ☞ ☞ Browser FeatureRefer to Appendix B at the back of this guide for diagramsshowing you how to use the User Codes Add, Delete,and Change browsers.

Deleting User Codes1. Access the User Menu.2. Press COMMAND until USER CODES? displays.3. Press any Select key. The keypad displays

ADD DEL CHG BAT.4. Press the second Select key, under DEL, to delete a user code

from the system. To delete a user code, you must have a usercode with a profile that has user code authority.

Note: Your system must have at least one user with user codeauthority in order to be able to add or delete user codes. Becareful not to delete all users with user code authority from yoursystem. Also, the user code used to enter the user menu to deletecodes cannot be deleted. In other words, you can not deleteyourself.

5. At the USER NUMBER: - prompt, enter the user number youwant to delete and press COMMAND. The display changes toUSER # DELETED.

6. The display then changes back to USER NUMBER: - allowingyou to delete another user. Press the Back Arrow key twice toexit the User Menu.

Page 29: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 25

Forgive Failure to ExitFailure to Exit is an Anti-pass back violation in which a user assignedwith anti-pass back has attempted to re-enter an area that theuser did not exit through.

Forgive Failure to Exit removes the anti-pass back violation. Seepage 5 for more information about anti-pass back.

1. After the USER CODES? menu has been accessed andADD DEL CHG BAT is displayed, press COMMAND. The keypaddisplays FRGV.

2. Press the top left key. The display changes to USER NUMBER:-3. At the USER NUMBER:- prompt, enter the user number to be

forgiven and press COMMAND. The User Code Browser describedin the Appendix can help find the appropriate user by name ifyou do not know the number.

4. To clear the FAILURE TO EXIT (Anti-pass back) violation for allusers enter 000 at the USER NUMBER:- prompt.

5. The keypad will display USER XXX FORGIVE to confirm, thenreturn to step 3 for the next user. Press the Back Arrow key toexit this menu.

Ambush CodesYour system may be programmed to allow user number 1 to be anAmbush code. This Ambush code functions identically to a standardcode with the exception that it sends a silent alarm to the centralstation. This silent alarm alerts the operator to a duress situationat the premises and prompts the immediate notification ofauthorities.

Refer to the System Setup section of this guide to see if yoursystem is programmed for Ambush. If so, do NOT program a codefor user number 1 unless you intend to use the Ambush function.

Page 30: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

26 XR200-485 User Menu

SchedulesSchedules are ideal for auto arming and disarming of individualareas and for creating Opening/Closing windows during whichusers can access the building or disarm the system. Havingseparate schedules allows you to create Opening/Closing windowsfor each day. One could be for normal business activity andanother could be for cleaning crews or a second shift. Onceprogrammed, these schedules operate continually until changed.

The Schedules function allows you to program into the system thetimes at which you normally turn your burglary protection on and offeach day of the week. This information can then be used by thesystem to automatically arm or disarm the burglary protection.

If your system does not use automatic arming, you can use theClosing Check/Extend feature with Schedules to help ensure yoursystem is armed manually at a specific time. This option sounds thekeypad buzzer and displays CLOSING TIME! or AREA LATE! when aschedule expires. Users still on the premises are reminded to armthe system or extend the schedule to a later time.

Your system provides you with five different types of schedules:Shift (S1, S2, S3, S4) allow you to set access and disarmschedules that occur at the same time each day until youchange them. Users are assigned to shifts using the ALOWauthority.Output (OUT) schedules allow you to set the times when relayoutputs or door strikes connected to your system turn ON and OFFautomatically.Door (DOOR) schedules allow you to set times when door strikesturn ON and OFF automatically.Holiday (HOL) dates allow you to enter special dates whichactivate Holiday Schedules that supercede all other schedules.Extend (EXT) schedules allow you to set a time for a one timeextend of the current running shift (S1 - S4) schedule.

Page 31: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 27

Setting Shift (S1 S2 S3 S4) Schedules1. Access the User Menu and press COMMAND until SCHEDULES?

displays. Press any Select key.2. The keypad displays S1 S2 S3 S4. Press the Select key under

the shift you want to program. This will allow you to enter aschedule that remains in place until you change or delete it.

3. Your system may be programmed to allow four shift schedulesper area, if so, AREA NO:- is displayed. Enter the area numberthat you are assigning to a schedule. Press the COMMAND keyto accept your Selection and continue setting schedules.

4. The keypad displays SUN MON TUE WED. Press the COMMANDkey to display THU FRI SAT HOL. Press the Select key underthe day you want the schedule to begin. If HOL is selected, goto Setting Holiday ABC Schedules for additional instructions.Note: After Selecting the day of the week or holiday for theschedule to begin, the keypad displays any currently programmedOpening and Closing times previously set for that day. Thisfeature allows you to review programmed schedules at anytime.A schedule entered in HOL (holiday) will be active andoverride SUN MON TUE etc. schedules anytime a holiday dateoccurs.

5. If Opening and Closing times are displayed, the keypad thendisplays DELETE KEEP. Press the Select key under DELETEto enter new times.

6. The keypad then displays OPENING TIME? followed by thedisplay MON � : AM PM. Enter the new opening time andselect AM or PM.Enter all schedule times using a 12 hour clock. For example,to enter 6 AM you would enter a 0 + 6 + 0 + 0 and press theSelect key under AM. For 11 PM you would enter a 1 + 1 + 0+ 0 and press the Select key under PM.The keypad then displays CLOSING TIME? followed by thedisplay MON � : AM PM. Enter the new closing time and selectAM or PM. Pressing the Select key under the day MON(whichever day is displayed) allows you to scroll through thedays of the week and create a schedule window that spansmultiple days.Note: You must enter an Opening and Closing time or the systemwill not recognize the schedule.The new schedule is now part of your system.

7. The keypad goes back to the SUN MON TUE WED displayallowing you to enter another schedule.

8. To clear a schedule press DELETE and then AM when theopening time is requested.Press the Back Arrow key to exit the User Menu.

Page 32: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

28 XR200-485 User Menu

Setting Output (OUT) and Door (DOOR) SchedulesThe Schedules function allows you to set up to 100 differentscheduled times for relay outputs and door access relays connectedto your system to turn ON and OFF automatically. The maximumnumber of schedules that can be assigned per door access relayor relay output is 8.

1. Access the User Menu.2. Press COMMAND until SCHEDULES? displays.3. After you have accessed the SCHEDULES? menu and the

schedule options, S1 S2 S3 S4, have been displayed, pressthe COMMAND key once more and the display will change toOUT DOOR HOL EXT. Press the Select key under OUT orDOOR.

4. At the OUTPUT NO: � or DOOR NO: � display, enter the outputnumber you want to program. Press the COMMAND key.

If adding a schedule and all 100 are currently in use, you will get anOUT SCHEDS FULL display. You must then delete an existingschedule.

5. The keypad displays SCHEDULE NO: -. Enter the schedulenumber (1 to 8) and press the COMMAND key.

6. The keypad displays SUN MON TUE WED. Press the COMMANDkey to display THU FRI SAT HOL.

7. Press the Select key under the day you want to program. Ifyou select HOL go to Setting Holiday ABC Schedules for moreinformation.

Note: After Selecting the day of the week for the schedule tooccur, the keypad displays any currently programmed ON OFFtimes previously set for that day. This feature allows you to reviewprogrammed schedules at any time.

8. If ON OFF times are displayed, the keypad then displaysDELETE KEEP. Press the Select key under DELETE to enternew times.

9. The keypad then displays ON TIME?. This is followed by thedisplay � : AM PM.Enter a new relay ON time and Select AM or PM.The display changes to OFF TIME?. This is followed by thedisplay � : AM PM.Enter a new OFF time for the relay.Enter all schedule times using a 12 hour clock. For example,to enter 6 AM you would enter a 0 + 6 + 0 + 0 and press theSelect key under AM. For 11 PM you would enter a 1 + 1 + 0+ 0 and press the Select key under PM.

10. The keypad returns to the day of the week display allowing youto enter another Output or Door schedule. To exit the usermenu or to go back to the S1 S2 S3 S4 display, press the BackArrow key.

11. To clear a schedule press DELETE and then AM when theopening time is requested.

Page 33: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 29

Setting Holiday ABC Schedules for S1, S2, S3, S4, OUT,and DOOR SchedulesThree Holiday schedules are available for each shift (S1, S2, S3,S4), each output relay (OUT), each door access relay (DOOR), andare available through their respective menu options. This allowsa shift, output, or door to have three different schedules forholidays. For example, Holiday Schedule A for those holidays whenthe building stays closed, Holiday Schedule B for a day that onlyopens for a morning, etc. Also, Holiday Schedules can be used tocross multiple days. These schedules become active and supercedethe current days schedule when a Holiday Date occurs. SeeSetting Holiday Dates (HOL).

1. After you have accessed the SCHEDULES? menu and theschedule options, S1 S2 S3 S4, have been displayed, pressthe COMMAND key until the display changes to SUN MON TUEWED. Press the COMMAND key again to display THU FRI SATHOL.

2. Press the Select key under HOL.3. The keypad displays HOL: A B C . Press the Select key under

A to set the first of three holiday schedules.4. The keypad displays A - : AM PM.

Note: After Selecting the schedule, the keypad displays anycurrent times previously set for that holiday. This feature allowsyou to review the programmed times.

5. If times are displayed, the keypad then displays DELETEKEEP. Press the Select key under DELETE to enter new times.

6. The keypad then displays ON TIME? or OPENING TIME?. Thisis followed by the display � : AM PM.Enter a new time and select AM or PM.The display changes to OFF TIME? or CLOSING TIME?. This isfollowed by the display � : AM PM.Enter a new time.Enter all schedule times using a 12 hour clock. For example,to enter 6 AM you would enter a 0 + 6 + 0 + 0 and press theSelect key under AM. For 11 PM you would enter a 1 + 1 + 0+ 0 and press the Select key under PM.

7. The keypad returns to HOL: A B C allowing you to enter aB and/or C holiday schedule for the same shift (S1, S2, S3, orS4), Output or Door. Go back to step 3 to add additionalholiday schedules.

8. To exit the user menu or to go back to the S1 S2 S3 S4 display,press the Back Arrow key. To clear a schedule press DELETEand then AM when the opening time is requested.

Page 34: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

30 XR200-485 User Menu

Setting Holiday Dates (HOL)Setting Holiday Dates provides the system with dates in the year thatthe normal opening and closing schedules are not used and aresuperceded by one of the Holiday Schedules A or B or C. Whenthe panel determines that it is a holiday, the Holiday Schedulesupercede the current schedule for that day. Up to twentydifferent holiday dates can be entered.

1. After you have accessed the SCHEDULES? menu and theschedule options, S1 S2 S3 S4, have been displayed, pressthe COMMAND key once more and the display will change toOUT DOOR HOL EXT. Press the Select key under HOL toprogram Holiday dates.

2. The keypad display changes to HOL: xx mm/dd A. You cannow enter the month and day for the first holiday. Press theSelect key under A to change to HOL B. Pressing againchanges to HOL C. Example: July fourth would be enteredby pressing the 0704 keys. The keypad will display HOL:1 07/04 B.

3. To step to the next holiday number, press COMMAND. Toclear a holiday press any top row key when the appropriateholiday number is displayed. Press the Back Arrow key whenHOL: 1 or the COMMAND key when HOL: 20 is displayed to exitthe menu.

Note: The Holiday Dates entered indicate the days of the yearwhen the HOL schedules will be used. When entering holidaydates that are used for door or output holiday schedules, the datemust be entered as a holiday date for all partitions that areavailable. For information on setting holiday schedules for Shift,Output, and Door, see Setting Holiday ABC Schedules.

Extending Schedules (EXT)Extending schedules (EXT) allows the Closing Check operation tobe delayed until the new closing time expires. This allows thecurrent shift schedule to ignore its closing time and not send aLATE TO CLOSE message to the central station. This function isdesigned to allow workers to stay later and does not extend dooraccess authority. The extended schedule is erased when itexpires.

1. After you have accessed the SCHEDULES? menu and theschedule options, S1 S2 S3 S4, have been displayed, pressthe COMMAND key once more and the display will change toOUT DOOR HOL EXT. Press the Select key under EXT toprogram Extended Schedules.

2. The keypad displays - : AM PM. Enter a time to extend thecurrent Closing Check open period. Press COMMAND to exit themenu.

A shift may be extended up to 23 hours and 59 minutes from thetime the extend function is performed.

To extend the system�s schedule after the closing time has beenreached:

1. Press any Select key. The keypad will display ENTER CODE:-.2. Enter your code and press COMMAND. The system�s schedule is

automatically extended one hour.3. The keypad then displays -: AM PM. You can enter a time to

extend the schedule for greater than one hour. Press AM orPM.Note: If the system is not armed by the scheduled closing time,a Late to Close report is sent to the central station. If theschedule is extended, a Schedule Change report is sent to thecentral station.

Page 35: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 31

Setting the Date and TimeAllows you to change the current date and time displayed on theSecurity Command keypad and used by the system.

Setting the System�s Date and Time1. Access the User Menu.2. Press COMMAND until TIME? displays. Press any Select key.3. The keypad displays the current day and time. Press the

COMMAND key. The keypad displays the current date. Pressthe COMMAND key to make any changes.

4. The keypad displays TIME DAY DATE.5. Press the Select key under TIME to change the time. The

keypad displays � : AM PM. Enter the current time and selectAM or PM. The display changes back to TIME DAY DATE.

6. Press the Select key under DAY to change the day of week.The keypad displays SUN MON TUE WED. If the current dayof the week is not displayed, press the COMMAND key.

7. The keypad displays THU FRI SAT. Press the Select key underthe correct day. You can use the Back Arrow key to togglebetween the two day of the week displays.

8. Press the Select key under DATE to change the date. Thekeypad displaysMONTH:- Enter one or two digits for the month.

Press COMMAND.DAY:- Enter up to two digits for the day.

Press COMMAND.YEAR:- Enter up to two digits for the year.

Press COMMAND.The display returns to the TIME DAY DATE display.Press the Back Arrow key to exit the User Menu.

Display EventsAllows you to review up to 1000 past door accesses and 200 pastsystem events. There are six event types:

Zone Activity - Zone alarms, troubles, and restorals.Opening and Closing - Arming and disarming of the system.User Code - Adding, deleting, and changing user codes.Schedule Changes - Adding, deleting, and changing schedules.Door Access - Each door access function used at a keypad.Supervisory - Problems with the system�s hardware components.

The system�s memory holds a maximum of 1000 past door accessevents and 200 system events for 45 days. Any event older than 45days is cleared automatically by the system. Also, once the full1200 events are stored, any new event causes the oldest event tobe cleared. See Appendix A for Display Events.

Page 36: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

32 XR200-485 User Menu

Using the Display Events1. Access the User Menu.2. Press the COMMAND key until DISPLAY EVENTS? displays.

Press any Select key.3. The keypad displays FRST LST PRT SRT. Select FRST (first)

to view the oldest to newest events. Select LST (last) to viewthe newest to oldest events. If you select FIRST, use theCOMMAND key to scroll up through the events. If you selectLAST, use the Back Arrow key to scroll down through theevents.Select SRT to sort through the Display Events log and collectinformation specific to a user or system event.Select PRT to print the complete Display Events log.

4. To use the Sort feature, press the Select key under SRT. Thekeypad displays FRST DATE: 8/21. Press any Select key andenter a 4-digit beginning date for the sort. Press COMMAND.

5. The keypad displays LAST DATE: 10/17. Press any Select keyand enter a 4-digit ending date for the sort. Press COMMAND.

6. The keypad displays USER NUMBER: -. To sort events for aparticular user, enter their user number or press COMMAND tosort for all users. To search for a user, press any Select keythen use the COMMAND and Back Arrow keys to browsethrough the user names in the system. When the user youwant is displayed, press any Select key then press COMMAND.

7. The keypad next displays five event types that you can includein the sort. Press the fourth Select key to display YES as theevent type name is displayed on the keypad. Press COMMAND.The following are the five sort event types:ACCESSES = door accesses granted.DOOR NUMBER = leave blank for all doors.

Note: If accesses is selected YES then only Door Access GrantedEvents will be included in the sort.

ZONE EVENTS = zone alarms, troubles, and restorals.ARM/DISARM = arming and disarming events.USER EVENTS = adding, deleting, and changing user codes.SUPERVISORY = system hardware problems and door accessdenied events.

8. After the last event type is displayed, the keypad againdisplays FRST LST PRT SRT. You can now view or print thenew sorted Display Events or press SRT for a new sort.

Page 37: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 User Menu 33

Service RequestYour user code profile may be programmed for Service Request.This feature of the User Menu allows you to just press any top rowSelect key while SERVICE REQUEST? is displayed and have thesystem automatically send a "Request for Service" message to thecentral station. The display changes to REQUEST MADEmomentarily to confirm your request was sent.

Fire DrillFire Drill is used to test the fire bells or fire horns in your system.The Fire Drill test turns on your system bell circuit, but does notsend a message to the central station.

Starting a Fire Drill test1. Access the User Menu.2. Press COMMAND until the FIRE DRILL? displays. Press any Select

key.3. The keypad displays SURE? YES NO.4. Press the Select key under YES to start the Fire Drill test.

Ending a Fire Drill test1. Enter your code at the keypad and press COMMAND to end the

Fire Drill.2. The Fire Drill test will automatically end with an ALARM

SILENCE or the programmed Bell Cutoff time.

Page 38: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

34 XR200-485B User�s Guide Supplement

This supplement is intended for use with the XR200-485B AccessControl Interface Card and includes information about theadditional features specific to the 485B.

Two Man RuleDuring an entry delay time, the keypad displays ENTER CODE:. Ifareas of your system are programmed for Two Man Rule, anytimea user enters a code to disarm a Two Man area or perform a dooraccess, the keypad displays 2ND CODE: - for 10 seconds. A secondand different user code must be entered within that 10-secondperiod. If you enter a second code that is the same as the first code,the keypad displays INVALID CODE. If you enter a second code thatdoes not have the equivalent authorization as the first code, thekeypad displays TRY AGAIN. If you do not enter the second codewithin the 10-second period, the display returns to normal.

Early Morning AmbushIf your system is programmed for Early Morning Ambush, when anarea is disarmed by a user code, an Ambush message will be sent tothe central station unless you enter a second user code. Thismessage is delayed by a programmed number of minutes to allowtime for you to inspect the premises for intruders. (See the SystemSetup on the next page for the amount of time programmed for theEarly Morning Ambush delay.) The second user code can be thesame code or a different code entered from the Status List in thedisarm menu. If the second user code is not entered before theEarly Morning Ambush delay expires, a silent Ambush message issent to the central station. The second user code must haveauthority to cancel the Early Morning Ambush operation.

System and Panic Zones TestSystem Test is used to test the system including battery, alarm bellor siren, and communication to a central station. Also, system testis used to test user panic zones. This allows you to test panicbuttons for operation without sending a message to the centralstation. The System Test or Panic Zone Test function beginsautomatically as soon as you select it.

Using the System Test1. Access the User Menu.2. Press COMMAND until SYSTEM TEST? displays.3. Press any Select key. The keypad displays SYSTEM PANICS.4. Press the Select key below SYSTEM.5. The System Test begins automatically. The keypad displays:

a) BELL SOUNDING during a two second bell testb) BATTERY - OKAY or BATTERY - TRBL to indicate the

condition of the battery* c) TRANSMIT TEST and ATTEMPT NO : 1 during the

transmit testd) TRANSMIT OKAY or TRANSMIT FAILED to show the

results of the transmit teste) TEST END to indicate the System Test is complete.f) You can end the transmit test by pressing the Back Arrow key.

* The transmit test does not operate on local systems.

XR200-485B User�s Guide Supplement

Page 39: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485B User�s Guide Supplement 35

Using the Panic Zone Test1. Access the User Menu.2. Press COMMAND until SYSTEM TEST? displays.3. Press any Select key. The keypad displays SYSTEM PANICS.4. Press the Select key below PANICS.5. The Panic Zone Test begins automatically and the keypad

displays TRIPS: END.During the Panic Zone Test, trip each panic zone (or button)on the system by pressing and holding the panic for 1 to 2seconds.

Note: You do NOT have to hold the panic for 2 seconds in normalmode. You are only required to hold the panic during thePanic Zone Test because the zone takes a little extra time toreport when the system is in test mode.Each time you trip a panic zone, the display number incrementsand the keypad buzzer sounds for two seconds.The number of panic zones tripped is constantly displayeduntil the test is ended or no panic zone activity has occurredfor 20 minutes.

6. Press the Select key below END to stop the Panic Zone Test.7. PANIC TEST OKAY is displayed when the Panic Zone Test is

completed and all zones tested OK.8. When the Panic Zone Test ends and a zone failed (did not trip)

during the test, the keypad displays the zone name andnumber and the buzzer sounds for one second. Press theCOMMAND key to display the next failed zone.

Note: During the Panic Zone Test, any zones that fail are not sentto the receiver or to the pager.

Testing your system�s burglary protectionThe System Test function should be a part of your weekly testingand should be followed by placing the burglary devices in ZoneMonitor mode. This allows you to open and then close eachprotected door and window while listening for the keypad to beepconfirming its operation. See Zone Monitor.

Bank Safe & VaultAreas of your system may be programmed for Bank Safe & Vault toprevent anyone from disarming an area outside of its scheduledopen period. Any zones in the area cannot be bypassed or forcearmed at arming. This operation provides added security to safeand vault areas of your system. Also, zones assigned to bank safeand vault areas may not be bypassed at arming.

Page 40: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

36 XR200-485 System Setup

System Setup RecordWe have provided this System Setup section to allow you to trackthe current and future status of the programmable options onyour Security Command system. If you make changes to thesystem, you should update the information contained on thesepages.

Your system is monitored by a central station.❏ Yes ❏ No

C/S Name: _________________________________________

Address: ___________________________________________

City/State: __________________________________________

Emergency Phone: ___________________________________

Service Phone: ______________________________________

Service Manager: ____________________________________

Your system sends Opening and Closing reports.❏ Yes ❏ No

Your system sends Zone Bypass reports.❏ Yes ❏ No

Your system sends Ambush reports.❏ Yes ❏ No

485B System Setup RecordThis section allows you to track the status of the XR200-485Bprogrammable options on your Security Command system.

Your system is programmed for Two Man Rule and requiresa second user code to be entered when disarming an area, orfor door access.

❏ Yes ❏ No

Your system is programmed for Early Morning Ambush andrequires a second user code to be entered to prevent anAmbush message from being sent to the central station.

❏ Yes ❏ No

Amount of time to enter second user code for the Early MorningAmbush delay:

Early Morning Ambush delay ______________ minutes.

Your area # ____ is programmed for Bank Safe & Vault toprevent anyone from disarming outside of the scheduledopen period.

❏ Yes ❏ No

System Setup

Page 41: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 System Setup 37

Security Command Keypad RecordDevice # Name Area

1 ____________________________ 1 2 3 4 5 6 7 8

2 ____________________________ 1 2 3 4 5 6 7 8

3 ____________________________ 1 2 3 4 5 6 7 8

4 ____________________________ 1 2 3 4 5 6 7 8

5 ____________________________ 1 2 3 4 5 6 7 8

6 ____________________________ 1 2 3 4 5 6 7 8

7 ____________________________ 1 2 3 4 5 6 7 8

8 ____________________________ 1 2 3 4 5 6 7 8

9 ____________________________ 1 2 3 4 5 6 7 8

10 ____________________________ 1 2 3 4 5 6 7 8

11 ____________________________ 1 2 3 4 5 6 7 8

12 ____________________________ 1 2 3 4 5 6 7 8

13 ____________________________ 1 2 3 4 5 6 7 8

14 ____________________________ 1 2 3 4 5 6 7 8

15 ____________________________ 1 2 3 4 5 6 7 8

16 ____________________________ 1 2 3 4 5 6 7 8

Which keypads display System Status?❏ 1 & 9 ❏ 2 & 10 ❏ 3 & 11 ❏ 4 & 12 ❏ 5 & 13

❏ 6 & 14 ❏ 7 & 15 ❏ 8 & 16 ❏ N/A

Which keypads display Armed Status?❏ 1 & 9 ❏ 2 & 10 ❏ 3 & 11 ❏ 4 & 12 ❏ 5 & 13

❏ 6 & 14 ❏ 7 & 15 ❏ 8 & 16 ❏ N/A

Which keypads provide Door Access reports?❏ 1 & 9 ❏ 2 & 10 ❏ 3 & 11 ❏ 4 & 12 ❏ 5 & 13

❏ 6 & 14 ❏ 7 & 15 ❏ 8 & 16 ❏ N/A

Area Names and Numbers RecordYour system may be divided into eight separate areas, each areacan have a name or description that displays at the keypad. Thiscan help you easily track events when they occur elsewhere inyour system.

Area Name

1 ___________________________________________

2 ___________________________________________

3 ___________________________________________

4 ___________________________________________

5 ___________________________________________

6 ___________________________________________

7 ___________________________________________

8 ___________________________________________

Suggestion: Photocopy this page before using.

Page 42: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

38 XR200-485 System Setup

Arm/Disarm Access OutputProfile # Profile Name Area Area Group

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

______ _____________________ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 _______

Arm

/Dis

arm

Alar

m S

ilenc

eSe

nsor

Res

etD

oor

Acce

ssAr

med

Are

asO

utpu

ts O

n/O

ffZo

ne S

tatu

sBy

pass

Zon

esZo

ne M

onit

orSy

stem

Sta

tus

Syst

em T

est

Use

r Pr

ofile

sU

ser

Code

sSc

hedu

les

Tim

eD

ispl

ay E

vent

sSe

rvic

e Re

ques

tFi

re D

rill

Exte

nd S

ched

ules

Tem

p U

ser

Code

Anti

-pas

s Ba

ck

Shif

t/Ti

me

Acce

ss

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

A4321

Suggestion: Photocopy this page before using.

Page 43: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 System Setup 39

User Codes RecordDepending on how your system is programmed, you may have 200 to 999 user codes available. As you add new users or change currentusers' codes, you can keep track of their profile number in the system. Use the following table to track custom user codes in your system.

#resU emaNresU #eliforP #resU emaNresU #eliforP

Suggestion: Photocopy this page before using.

Page 44: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

40 XR200-485 System Setup

Schedules RecordeludehcS emaNaerA sutatS NUS NOM EUT DEW UHT IRF TAS ALOH BLOH CLOH

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

4S3S2S1S#aerA

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

#rooD#tuptuO

____________________________

nepOesolC

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

M_:M_:

Page 45: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 System Setup 41

Holiday Date RecordYour system has up to 20 holiday dates available that supercede allregular scheduled times for that day.

# Date (mm/dd) HOL (circle one)1. _____/_____ A or B or C

2. _____/_____ A or B or C

3. _____/_____ A or B or C

4. _____/_____ A or B or C

5. _____/_____ A or B or C

6. _____/_____ A or B or C

7. _____/_____ A or B or C

8. _____/_____ A or B or C

9. _____/_____ A or B or C

10. _____/_____ A or B or C

11. _____/_____ A or B or C

12. _____/_____ A or B or C

13. _____/_____ A or B or C

14. _____/_____ A or B or C

15. _____/_____ A or B or C

16. _____/_____ A or B or C

17. _____/_____ A or B or C

18. _____/_____ A or B or C

19. _____/_____ A or B or C

20. _____/_____ A or B or C

Output Relay RecordYour system has ____ output relays that are used to control variousfunctions within the building or access around its perimeter.Below is a list of the devices they control.

Output # Output Name___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

___________ ________________________________

Use the Output number in the User Menu when setting OutputSchedules or using the Outputs ON OFF option to manually toggle therelays.

Page 46: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

42 XR200-485 Appendix A

About the Display Events SectionThis section of the user�s guide shows the User's Guide DisplayEvents items for both 16-character (single line) and 32-characterkeypad displays. While in the Display Events function, use theCOMMAND and Back Arrow keys to go forward or backwardthrough the list of events.

To view more information about each display, press the Select keyas directed in the explanations below. Remember that the Selectkeys are numbered from left to right for the purpose of thismanual. The actual Select keys on your keypad will not benumbered or labeled.

Arming and Disarming Event DisplaysThis displays any arming or disarming of system areas.

16-Character Display Description

ARM 3 12 1017 Area 3 was armed by user 12 on Oct. 17.Press the second Select key, under 3, forthe area name, the third key for the username, or the fourth key for the time thearming occurred.

32-Character Display Description

ARM 5:10P 10/ 17 The area was armed at 5:10 PM. WAREHOUSE Press any Select key to display the area

number and user number, and then anySelect key to display the user name.

Arming Event Types - There are 2 event type you may see here:

ARM - User armed the system DIS - User disarmed the system

Zone Event DisplaysThis displays alarms, troubles, and other events that could occur onyour protection zones.

16-Character Display Description

2 BURG ALR 1017 A burglary alarm occurred on zone 2.Press the fourth Select key for the timethe alarm occurred.

32-Character Display Description

ALR 10: 23P 10/17 An alarm occurred at 10:23 PM onBASEMENT DOOR Oct. 17. Press any Select key to see

the zone number and zone type.Zone Type - There are 7 possible zone types you may see here.

FIRE - Fire PANC - Panic BURG - BurglaryEMRG - Emergency SUPV - SupervisoryAUX1 - Auxiliary 1 AUX2 - Auxiliary 2

Event Types - There are 7 event type you may see here:

ALR - Alarm TBL - Trouble RST - Restore

LOW - Low battery MIS - Missing wireless transmitter

FLT - Zone Fault SVC - Service smoke detector

Note: LOW and MIS are for wireless systems only.

Appendix A

Page 47: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix A 43

Supervisory Event DisplaysThis displays the date and time of an automatic test report.

16-Character Display Description

AUTO RECALL 1017 The test report was sent on Oct. 17.

32-Character Display Description

MSG 11: 58P 10 / 17 The test report was sent to theAUTO RECALL central station at the date and time

shown.

User Code Change Event DisplaysThis displays any addition, deletion, or change to a user code.

16-Character Display Description

12 ADD 19 1017 User 12 added user 19 on Oct. 17. Pressthe right Select key for the time thisoccurred.

32-Character Display Description

ADD 11: 41A 10 /17 User 19 added by user 12 at 11:41 AM.US:19 BY US:12 Press the Select key under either user

(US:) number for the user name.

User Code Event Types - There are 3 event type you may see here:

ADD - User added DEL - User deletedCHG - User code or authority level has been changed.

Page 48: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

44 XR200-485 Appendix A

ACC 5:18P 10/173 USER:024

System Monitor Event DisplaysThis displays any problems with the system's AC power, battery, orphone line(s) or any opening of a tampered panel box.

16-Character Display Description

POWER TBL 1017 An AC failure occurred on Oct. 17.Press the fourth Select key for thetime.

32-Character Display Description

TBL 11:41A 10/17 An AC failure occurred at 11:41 AMPOWER on Oct. 17.

System Monitor Event Types - There are 2 event types:

TBL - Trouble RST - RestoreSystem Monitor Event Names - There are 5 system monitors:

POWER - AC power to panel BATTERY - On panel

LINE 1 - Phone line number 1

LINE 2 - Phone line number 2 TAMPER - On panel box

Door Access Event DisplaysThis displays the keypad address where a Door Access occurredand the user number of the person granted access.

16-Character Display Description

DOOR 3 024 1017 Door (keypad) #3 was accessed by user 24on Oct. 17. Press the second Selectkey to display the reason that accesswas denied. Press the third to displaythe user name and the fourth Selectkey for the time of occurrence.

32-Character Display Description

Door (keypad) #3 was accessed by user24 at 5:18 PM on Oct. 17. Press the firstSelect key to display Door name whereto access occurred. Press the secondSelect key to display the reason thataccess was denied. Press the thirdSelect key for the name of the device,or the fourth key for the user name.

About Door AccessDoor Access is a feature available on certain Security Commandkeypads that contain a built-in door releasing relay and proximityreaders. When power for an electric door strike or magnetic lockis connected to the relay�s contacts, only users entering a validuser code can release the lock and gain access to the area.

The Display Events feature logs the user number and name of theperson granted access, the date and time, and from which keypadthey entered their code.

Page 49: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix A 45

Schedule Change Event DisplaysThis displays Changes made to the system�s schedules.

16-Character Display Description

S1 MON 024 1017 S1 schedule for Monday was changed byuser 24 on Oct. 17. Press the fourthSelect key for the time of occurrence orthe third Select key for the user name.

32-Character Display Description

S1 9:41A 10/17 S1 schedule for Monday was SCH MONUSER:024 changed by user 24 at 9:41 AM on

Oct. 17.

Schedule Types - There are 5 possible schedule types:

S1 S2 S3 S4 - Standard OUT - Output DOOR - Door

HOL - Holiday EXT - Extend

MON - This is the day of the week in which the schedule changeoccurred. The days are displayed using three letters. Press thefirst Select key to display the scheduled Opening time and onceagain for the scheduled Closing time.

024 - User number of the person who made the change. Press thethird Select key (the Select key under 024) to display the user'sname.

Zone Bypass Event DisplaysThis displays the bypassing of system zones.

16-Character Display Description

26 BYPS 12 1017 Zone 26 bypassed by user 12. Press thefirst Select key for the zone name andthe fourth Select key for the time.

32-Character Display Description

BYP 5:18P 10 / 17 The east window zone was bypassed. EAST WINDOW Press a Select key for the zone

number and user number. Pressagain for the user name.

Bypass Event Types - There are 3 event types:

BYP - Bypass RST - Restore FRC - Force Arm

Note: You may sometimes see the user as SWG. This is short forSwinger Bypass which is an automatic function that allows thesystem to bypass a zone.

Page 50: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

46 XR200-485 Appendix B

SELECT OUTPUT . . .SELECT DOOR . . .

COMMAND

OFFICE FRONT DR

OUTPUT: - ON OFFDOOR: - ON OFF

OUTPUT:127 ON OFFDOOR: 128 ON OFF

OUTPUTS ON /OFF?OUTPUTS DOOR

Access the User Menu. Pressthe COMMAND key untilOUTPUTS ON/OFF? displays.Press the SELECT key underOUTPUTS or DOOR.

This prompt allows you to searchfor a door or an output. Press theCOMMAND key to scroll throughthe list of doors or output names.

Press one of the two left SELECTkeys.

When the door or output you want isdisplayed, press any SELECT key.

The display shows the door or outputnumber.

Outputs On/Off BrowserZONE STATUS?

ARM BYPS ALR NBR

ZONE NO: -

SELECT ZONE . . .

COMMAND

Access the User Menu. PressCOMMAND until ZONESTATUS appears.

Press any SELECT key thenpress the SELECT key underNBR.

SELECT AREA . . .

COMMAND

FRONT OFFICE

24 HOUR ZONES

Press one of the left twoSELECT keys to browsethrough the names of zones.

When the area where the zone islocated is displayed, press anySELECT key. When you are browsingfor a 24 hr. zone, press COMMAND atthe last area.

This prompt allows you to search fora zone by area. Press theCOMMAND key to scroll through thelist of areas.

After all the areas aredisplayed, the system allowsyou to search through the 24hour zones (Fire, Panic,Supervisory, etc.).

Press the COMMAND key to scrollthrough the list of all zone names.

EAST DOORWhen the correct zone name isdisplayed, press any SELECT key.

ZONE NO : 0 1 2Verify the zone number matchesthe previously shown name.

EAST DOOR - OKAY

The system displays one of thesezone status messages:

-OKAY = the zone is normal-BYPAS = the zone is bypassed-BAD O = the zone is open-BAD S = the zone is shorted

Press COMMAND.

SELECT ZONE . . .

HALL SMOKE

ZONE NO : 0 3 4

HALL SMOKE- OKAY

Press COMMAND.

When the correct zone name isdisplayed, press any SELECT key.

Verify the zone number matches thepreviously shown name.

Pressing COMMANDallows you to enteranother zone number.

The system displays one of thesezone status messages:

-OKAY = the zone is normal-BYPAS = the zone is bypassed-BAD O = the zone is open-BAD S = the zone is shorted

COMMAND

COMMAND

COMMAND

COMMAND

COMMANDCOMMAND

COMMAND

Zone Status Browser

Appendix B

Page 51: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix B 47

SELECT ZONE . . .

COMMAND

Access the User Menu. PressCOMMAND until ZONE MONITOR?displays. Press any SELECT key.

Press the SELECT key under NBR.

COMMAND

FRONT OFFICE When the area where the zone is locatedis displayed, press any SELECT key.

Press either of the two left SELECT keys.

Press the COMMAND key to scrollthrough the list of all zone names.

EAST DOOR When the correct zone name isdisplayed, press any SELECT key.

ZONE:012 ADD RMVThe display shows the zone number.

ZONE MONITOR?

ALL NBR

ZONE: - ADD RMV

Selecting ADDputs the zone inthe monitor mode.

Selecting RMV removes thezone from the monitormode.

SELECT AREA . . . This prompt allows you to search for azone by area. Press the COMMAND keyto scroll through the list of areas.

Bypass Zones Browser Zone Monitor Browser

BYPASS ZONES?

ZONE: - RST BYP

SELECT ZONE . . .

COMMAND

Access the User Menu. PressCOMMAND until BYPASS ZONESappears. Press any SELECT key.

Press either of the two left SELECTkeys.

SELECT AREA . . .

COMMAND

FRONT OFFICEWhen the area where the zone is locatedis displayed, press any SELECT key.

This prompt allows you to search for azone by area. Press the COMMANDkey to scroll through the list of areas.

Press the COMMAND key to scrollthrough the list of all zone names.

EAST DOOR When the correct zone name isdisplayed, press any SELECT key.

ZONE:012 RST BYPThe display shows the zone number.Press the SELECT key under RST toReset the zone. Press the SELECT keyunder BYP to Bypass the zone.

ZONE: - RST BYP The display returns to the ZONE:prompt allowing you to enteranother zone number.

Page 52: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

48 XR200-485 Appendix B

Add User Profiles Browser Delete User Profiles Browser

PROFILE 12 ADDED

COMMAND

Follow the prompts to selectall profile options and pressCOMMAND when done.

USER PROFILES?

ADD DEL CHG

PROFILE NO: -

PROFILE NO: 012

Access the User Menu. Press COMMANDuntil USER PROFILES? displays. Pressany SELECT key.

Press the SELECT keyunder ADD.

At this prompt, you can enter a newprofile number or scroll through theavailable (unused) profile numbers.

Enter a new profile number.View available profile numbers.

Press any SELECT key.The first available profilenumber is displayed.

PROFILE NO: 12

USER PROFILES?

ADD DEL CHG

PROFILE NO: -

Access the User Menu. PressCOMMAND until USER PROFILES?displays. Press any SELECT key.

Press the SELECT keyunder DEL.

PROFILE 12 DELTD

SELECT PROFILE . . .

Enter a profile number.

To scroll through the list ofprofiles, press theCOMMAND key.The next used profilename is displayed.

ENGINEERING

Press COMMAND.

PROFILE NO: 12

COMMAND

When you scroll to the profileyou want to delete,press any SELECT key.

Press any SELECT key.

PROFILE NO: 12

COMMAND Press the COMMANDkey to delete the profile.

COMMAND

Page 53: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix B 49

Change User Profiles Browser Add User Codes Browser

USER PROFILES?

ADD DEL CHG

PROFILE NO: -

SELECT PROFILE . . .

Access the User Menu. Press COMMANDuntil PROFILES? displays. Press anySELECT key.

Press the SELECT key underCHG.

At this prompt, you can enter a profilenumber or scroll through the list ofprofile names

Enter a profile number. Press any SELECT key.

Press COMMAND.Press COMMAND.

PROFILE NO: 012

PROFILE NO: 12

SHIPPINGThe first profile name isdisplayed. To scrollthrough the list press theCOMMAND key.If this is the profile youwant to change, pressany SELECT key.

Verify the profile number.

COMMAND Press COMMAND.

PROFILE 12 CHNGD

Follow the prompts tocomplete the profilechange.

COMMANDCOMMAND

COMMAND

SHIPPING

When you have completedchanges to the profile,press COMMAND.

You can also pressany SELECT key toclear the profilename and use thedata entry keys toenter a new name.

_

USER CODES?

ADD DEL CHG

USER NUMBER: -

USER NUMBER: 012

COMMAND

CODE NO: 1 2 3 4

Access the User Menu. Press COMMANDuntil USER CODES? displays. Press anySELECT key.

Press the SELECT keyunder ADD.

At this prompt, you can enter a newuser number or scroll through theavailable (unused) user numbers.

Enter a new user number.View available user numbers.

Press any SELECT key.

COMMAND

CODE NO: -

Press COMMAND.Press COMMAND.

Enter the new user code.

Verify the number and pressCOMMAND.

The first available usernumber is displayed.

USER 012 The default user name appears.Press any SELECT key to clear thisname.

COMMAND

- See the Entering Custom Namesdiagram at the end of this guide.

USER NUMBER: 12

Page 54: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

50 XR200-485 Appendix B

USER CODES?

ADD DEL CHG

USER NUMBER: -

MIKE JONES

COMMAND

Access the User Menu. Pressthe COMMAND key until USERCODES? displays. Press anySELECT key.

Press the SELECT keyunder DEL.

At this prompt, you can enter a usernumber or scroll through the list of usernames.

Enter a user number.View current user names.

Press any SELECT key.

COMMAND

USER 12 DELETED

Press COMMAND.Press COMMAND.

USER NUMBER: 013

The first available username is displayed.

USER NUMBER: 12

KATIE SMITH The next available username is displayed.

If this is the user youwant to delete, press anySELECT key.

Verify the user number.

COMMAND

USER 13 DELETED

Press COMMAND.

Delete User Codes Browser Change User Codes Browser

USER CODES?

ADD DEL CHG

USER NUMBER: -

MIKE JONES

COMMAND

Access the User Menu. PressCOMMAND until USER CODES?displays. Press any SELECT key.

Press the SELECT keyunder CHG.

At this prompt, you can enter a usernumber or scroll through the list of usernames

Enter a user number.View current user names.

Press any SELECT key.

COMMAND

CODE NO: * * * * *

Press COMMAND.Press COMMAND.

USER NUMBER: 013

The first available username is displayed.

USER NUMBER: 12

KATIE SMITH The next available username is displayed.

If this is the user youwant to change, pressany SELECT key.

Verify the user number.

COMMAND Press COMMAND.

CODE NO:

Press any SELECT key toclear the present code.

COMMANDEnter a new code andpress COMMAND.

Follow the prompts to complete the codechange. You can also press any SELECT keyhere to clear a custom user name and use thedata entry keys to enter a new user name.

KATIE SMITH

Page 55: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix B 51

Output Groups Browser Entering User Names

OUTPUT GROUP: -

EXECUTIVE FLOORS

Access OUTPUT GROUP:- inthe USER PROFILES? menu.Press any SELECT key.

COMMAND Press COMMAND.

The first output groupname is displayed.

ENGINEER FLOORS The next outputgroup name isdisplayed.

SELECT GROUP . . . At this prompt you canscroll through the list ofoutput group names.

COMMAND Press COMMAND.

OUTPUT GROUP: 9 Press any SELECT keyand the Output Groupnumber is displayed.

– Once you've cleared the defaultname, the display shows just adash on the left side.

To enter a custom name intothe keypad, you'll be usingthe 3 rows of number keys.

To enter a custom name, pressthe number key above the letteryou want to enter.

Under each numberkey are three letters.

1 2 43

5 6 87

9 0 COMMAND

{

1A B C

1

A B C

1

2

Once the letter you want isdisplayed, press the number keyabove the next letter you want toenter.

You can enter up to 16 charactersfor each name into the keypad.

A

1 2 43

5 6 87

9 0 COMMAND

3

4

9

The nine and zero keys . . .

Y Z (space)

Pressing the 9 key provides youwith Y, Z, and a space that youcan use between names. Forexample: BOB S MI T H.

0

– .Pressing the 0 (zero) key providesyou with a (dash), (period),(asterisk), and a (pound sign).

* #

With the number displayed, pressthe SELECT key that matches theposition of the letter. See example.

Page 56: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

52 XR200-485 Appendix C

Appendix C

ABC SECURITYFRI 2: 5 1 AM

POWER

DISARMING WITH ENTRY DELAY

Once the protected door is opened and the entry delay starts, thekeypad displays ENTER CODE: -. Present your card to the reader. Onceit is validated, the system disarms all areas accessible by you. Areasystems provide a delay to allow selected areas only to be disarmed. SeeArming and Disarming above.

USING THE ACCESS READER FOR USER MENU ACCESS

You can also use a card reader to access the User Menu when theMENU? NO YES display is shown and a code is requested.

ARMING AND DISARMING AN AREA SYSTEM

Press Command. The keypad displays ARM DISARM.Press the Select key under either option. Thekeypad displays ENTER CODE: -. Present your cardto the reader. Once it is validated by the system,all areas accessible by you arm or disarmautomatically. Select NO to arm or disarm individualareas. Select YES, or simply wait, and the keypad will automatically arm or disarm all areas for which you are authorized.

POWER

ABC SECURITY

ENTER CODE: -

Access door isopened.

POWER

The system disarms the areas. Area systems allow a delay foryou to Select only certain areas. See Arming and Disarming.

ABC SECURITYARM DISARM

ABC SECURITYENTER CODE: –

ABC SECURITYALL? NO YES

POWER POWER POWER

DOOR STRIKE

From the Status List, present your card to the reader. Once it is validatedby the system, the Door Strike relay activates. If you are entering an armedarea which you are assigned, accessing the area will automatically cause it tobe disarmed.

While the keypad is in the Status List, present your access card. The relayactivates momentarily during which you must open the door. Once you openthe door, you have 30 seconds to exit and close the door before the zone 2 Soft-Shunt expires.

Easy Entry� User's Guide

Page 57: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix C 53

Pager Direct�

Security Command Alphanumeric Paging

Area Names

Pager Direct�

Security Command Numeric Paging

Area NamesList your system's area names and numbers below:

Area Name Area Name

1 _______________________ 3______________________

2 _______________________ 4 ______________________

Service Department Phone: ______________________

Emergency Phone: _____________________________

Central Station Phone: ____________________________

Cut along dotted lines

Fold

List your system's area names and numbers below:

Area Name Area Name

1 _______________________ 3______________________

2 _______________________ 4 ______________________

Service Department Phone: ______________________

Emergency Phone: _____________________________

Central Station Phone: ____________________________

Cut along dotted lines

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Pager Direct� User's GuidePager Direct uses the reporting capability of your security system to dial your pager number and send reports much like someone sendingyou a pager message. You can receive reports of alarms, troubles, or armings and disarmings of the system and know at a glance the statusof your system.

Page 58: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

54 XR200-485 Appendix C

This number has been programmed into your Security Commandsystem as an identifier. Whenever the system sends a messageto your pager, it will always send the account number first toidentify itself.

If this message is for a zone, the 1- to 3-digit zone number isdisplayed. If this message is for areas that are being armed ordisarmed, the area numbers are shown in sequential order.Example: 1 2 4.

00128–301234

AccountNumber

MessageI D

AlwaysZero

Zone, Area, orUser Number

Security Command Numeric PagingSecurity Command Alphanumeric Paging

Account NumberWhenever the system sends a message to your pager, it will alwayssend the account number first to identify itself. After theaccount, you will see the following messages:

Typical Zone Event Display Description20002 001 NORTHWEST DOORS BURG *ALARM* SHIPPINGAccount Zone Zone Name Zone Type Event Area Name

Zone Types - BURG, FIRE, SUPV (Supervisory), PANC (Panic), EMRG (Emergency), AUX1,or AUX2

Events - ALARM or TROUBLE

Typical Arming/Disarming Display Description20002 ARMED 0016 01 EAST WAREHOUSEAccount Event User # Area # Area Name

Events - ARMED or DISARMED

Typical System Event Display Description20002 LATE TO CLOSEAccount Event

Events - LATE TO CLOSE (The system was not armed at its scheduled closing time)ALARM CANCELLED (An alarm has been cancelled by an authorized user)

Alphanumeric Pager Display Numeric Pager Display

This is always a single digit, 1 to 7, that describes the message.1 = Zone Alarm 5 = Late to Close2 = Zone Trouble 6 = User Check-in3 = Area(s) Arming 7 = Local Message4 = Area(s) Disarming

Account Number

Message ID

Zone, Area, or User Number

Page 59: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix C 55

FA113 User's GuideThese instructions guide you through the operation of your system using the FA113 Wireless Keychain Remote. The FA113 uses the audibleoutput capability of the Security Command keypad to sound confirmation tones. It is recommended that you use the FA113 within hearingdistance of these keypads.

Disarming the System1. Press the OFF button once. The Security Command keypads emit a single two second beep to confirm the disarming.

Arming an Area System1. Press the ON button once to arm the following areas:

1. ___________________ 2. ___________________

3. ___________________ 4. ___________________

The Security Command keypads emit a single beep to confirm the arming.

Disarming an Area System1. Press the OFF button once to disarm the above areas. The keypads emit a single beep to confirm the disarming.

Using the ALERT ButtonsPressing the two ALERT buttons simultaneously sends a Panic alarm to the panel. If your system is monitoredby a central station, the proper authorities will be notified of the alarm. OFF ON

ALERT ALERT

ALERT buttons

Page 60: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

56 XR200-485 Appendix C

Frequently asked questionsThis section attempts to answer questions you might have regardingthe operation of your Security Command system.

Q. If I bypass an exit delay door when I arm the system, will I getan alarm if I come through it later?

A. You will not get an alarm from the door because it is bypassed,but if you also walk through a motion detector or other armed doorinside the premises you will get an alarm.

Q. When I arm or disarm my Area system, I get ALL? NO YESdisplayed. Does this mean all areas in the system?

A. Choosing YES arms or disarms all areas that are authorized foryour user code.

Q. How do I create a schedule that starts at 8:00 am on Monday andends at 5:00 PM on Friday.

A. In the days of the week display, select MON (Monday). For theOPENING TIME?, enter 0 + 8 + 0 + 0 AM. For the CLOSING TIME?, atthe MON � : AM PM display press the Select key under MON; thisscrolls through the days of the week. Stop at the day you want theschedule to end. Next, enter 0 + 5 + 0 + 0 PM into the FRI � : AMPM closing time display. Press COMMAND. Press the Back Arrow keyto exit the User Menu.

This sets the opening time to 8:00 am Monday and the closing timeto 5:00 PM Friday. You can substitute any other day or time in thisexample.

Q. What do I do if I want to be in the building past the scheduled closing(arming) time?

A. If your system is programmed for closing check, the keypad emitsa steady tone prior to the system arming. During this tone, pressingany Select key displays ENTER CODE: . Enter your user code andpress COMMAND.

The keypad now displays the enter time display � : AM PM. Enterin the new time you want the system to arm and press COMMAND.The time you enter may extend past midnight by pressing the AM keyafter the appropriate time has been entered.

Page 61: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

XR200-485 Appendix D 57

Common Keypad DisplaysListed below are several keypad messages you may see on the display. Follow the instructions in the Possible Solutions column to correctthe problem. In many cases, you will need to call a service person to correct the problem.

Appendix D

Message Meaning Possible Solutions

Invalid Area The user has attempted a door access for an area they are not assigned.

Assign the user acces to this area if desired; otherwise the user cannot access the area.

Invalid Code The user code you have entered is not recognized by the system.

Check the user code and try again.

Invalid LevelThe code you have used does not have the authority level to access the desired option.

Check the user level to see is you have the correct level set for the code. Remember that you can only grant a user authority if you have the same authority or greater: You can't give what you don't have.

Invalid Profile A user has attempted a function that is outside of the assigned profile.

Check the user's profile settings.

Invalid Time A user code assigned to a specific schedule has entered outside of the valid schedule.

See Schedules and User Codes.

Enter 2nd Code The area you are attempting to disarm or access is a Two Man area.

A second and different user must enter a valid user code.

Closing TimeThe schedule has expired but the area has not been armed.

Users still on the premises are reminded to arm the system or extend the schedule to a later time.

Late to CloseThe system was not armed at its scheduled closing time.

Users still on the premises are reminded to arm the system or extend the schedule to a later time.

Failed to ExitA user assigned the anti-pass back option has attempted to re-enter an area which they did not exit properly.

The user must exit the area through the proper door. If not possible, your system administrator should select the Forgive option in the User Codes menu option.

Page 62: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

58 XR200-485 Appendix D

Common Keypad Displays Continued

Message Meaning Possible SolutionsAC Trouble The system is not getting proper power. Contact your representative.

Battery Trouble Battery is either low or missing. Contact your representative. Phone Line 1 Trouble The panel is looking for phone jack supervision. Contact your representative. System Trouble or Service Required

There is a problem with one or more of the components in the system.

Contact your representative.

System Busy The system is performing another task with a higher priority.

Contact your representative.

No supervised device on bus Contact your representative. Low Voltage or an open yellow wire Contact your representative. Two devices on same address Contact your representative.

Transmit Trouble The panel has attempted to communicate with the central station 3 times and has not succeeded.

Contact your representative.

Transmit Fail The panel has attempted to communicate with the central station 10 times and has not succeeded.

Contact your representative.

Wireless Trouble The wireless receiver is not communicating with the 472 Hard-Wire-Less Card.

Contact your representative.

Non-Polled Address The device is not set to STD (standard) or FIRE in Device Setup of programming.

Contact your representative.

4-Wire Bus Trouble

Page 63: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

Index 59

Index

2-Button Panic Keys ................ 3485B System Setup Record ....... 37Alarm Silence ........................ 13ALERT Buttons ...................... 55Ambush Codes ...................... 26Anti-Pass Back ....................... 5AREA LATE! ........................... 27Area Names and Numbers Record38Armed Areas Display ............... 15Arming ................................. 8Bank Safe & Vault .................. 36Browser .............................. 53

Add User Codes ................. 53Add User Profiles ................ 53Bypass Zones .................... 53Change User Codes ............ 53Change User Profiles ........... 53Delete User Codes .............. 53Delete User Profiles ............ 53Outputs On/Off ................ 53Zone Monitor .................... 53Zone Status ...................... 53

Bypass Zones ....................... 17Bypassing when arming

bad loops ....................... 3CLOSING TIME! ..................... 27Common Keypad Displays ... 57, 58Date and Time ...................... 31Disarming ............................ 10

Display Events ................ 32, 42Arming and Disarming Event . 42Door Access Event ............. 45Schedule Change Event ........ 45Supervisory Event .............. 44System Monitor Event ......... 44User Code Change Event ..... 44Zone Bypass Event ............. 53Zone Event ....................... 43

Door Access ......................... 14Early Morning Ambush ............. 34Extending Schedules ........ 11, 30FA113 User's Guide ................. 55Failure to Exit ...................... 25False Alarms .......................... 1Fire Drill ............................. 34Forgive Failure to Exit ............ 25Frequently asked questions ..... 56General Arming Operation ......... 8General Disarming Operation .... 10Holiday Date

Setting Holiday Dates .......... 30Holiday Date Record .............. 41Keypad

2-Button Panic Keys ............. 3Back Arrow Key .................. 3Command Key .................... 3Data Entry Keys ................. 3Tones ............................... 4User Menu..................... 1, 12Wireless Displays ................ 5

LEDAC .................................. 3Armed .............................. 3

Outputs On Off .................... 15Panic Zone Test ..................... 35Profiles ............................... 20

Adding ............................ 20Changing ......................... 22Deleting .......................... 22Name .............................. 20Number ........................... 20

SchedulesExtend (EXT) .................... 27Extending Schedules ........... 30Setting Shift Schedules ........ 27

Schedules ............................ 26Extending Schedules ............ 6Holiday (HOL) ................... 27Output (OUT) ................... 27Setting Holiday ABC Schedules 29Setting Output and Door

Schedules ..................... 28Shift (S1, S2, S3, S4) ............ 27

Schedules Record .................. 41

Security Command Keypad ..... 1, 3Record ............................ 37

Sensor Reset ........................ 13Service Request .................... 34Status List ........................... 7System Setup Record .............. 36System Status ...................... 18System Test ......................... 19TEMP CODE .......................... 22Two Man Rule ........................ 34User Codes .......................... 23

Adding ............................ 23Changing ......................... 24Deleting .......................... 24Names ............................. 23Profile ............................. 23

User Menu Options ................ 12User Options Menu ................. 4User Profiles ........................ 20XR200-485B Panic Test ............ 20Zone Monitor ....................... 17Zone Status ......................... 16

Page 64: XR200-485 User™s GuideXR200-485 Introduction 1 About Your Security System The Security Command system has been designed with your safety and comfort in mind. It uses the latest in

LT-0364 (3/03)