4
50 Nominal data Type Motor VAC Hz rpm kW A μF/VDB Pa °C *6D 800 M6D 138-LA -10° p. 126 F1b)/F2b) 3~ 480 Y 60 1100 1.98 3.60 220 -40 to +60 3~ 400 Y 60 1050 1.80 3.55 200 -40 to +60 *6D 800 M6D 138-LA -5° F1b)/F2b) 3~ 230 Δ 60 1050 1.80 6.15 200 -40 to +60 A B C Curve Blade angle Nominal voltage Frequency Speed (1) Max. power input (1) Max. current draw (1) Capacitor Max. operative range Perm. amp. temp. Electr. connection (1) Nominal data in operating point with maximum load 3 subject to alterations AC axial fans - HyBlade ® Ø 800 Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium Number of blades: 5 Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A" counter-clockwise, seen on rotor Type of protection: IP 54 (in accordance with EN 60529) Insulation class: "F" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharge holes: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings 0 [Pa] [in H 2 O] [m 3 /h] [CFM] 80 40 160 120 200 0,2 0,4 0,3 0,5 0,6 0,7 0,8 A B C 2 3 1 2 3 1 0,1 4000 8000 12000 16000 20000 2000 4000 8000 10000 12000 6000 Curves n [rpm] P1 [kW] I [A] LwA [dB(A)] A A A B B B C C C 1 2 3 1 2 3 1 2 3 1130 1115 1100 1100 1075 1050 1100 1075 1050 1.51 1.75 1.98 1.41 1.62 1.80 1.41 1.62 1.80 77 78 80 77 77 79 77 77 79 3.04 3.30 3.60 2.95 3.27 3.55 5.13 5.69 6.15 3~ 480 Y 60 1080 2.18 3.80 150 -40 to +60 3~ 400 Y 60 1030 1.99 3.78 135 -40 to +60 3~ 230 Δ 60 1030 1.99 6.50 135 -40 to +60 D E F Split by PDF Splitter

Split by PDF Splitter AC axial fans - HyBlade · 2017-01-12 · 54 AC axial fans - HyBlade® Ø 800, drawings for direction of air flow "V" g±2 99x99 76 c±3 d±2 162 ±0,3 8xM10

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Split by PDF Splitter AC axial fans - HyBlade · 2017-01-12 · 54 AC axial fans - HyBlade® Ø 800, drawings for direction of air flow "V" g±2 99x99 76 c±3 d±2 162 ±0,3 8xM10

50

Nominal data

Type Motor VAC Hz rpm kW A μF/VDB Pa °C

*6D 800 M6D 138-LA -10°

p. 126

F1b)/F2b)3~ 480 Y 60 1100 1.98 3.60 — 220 -40 to +603~ 400 Y 60 1050 1.80 3.55 — 200 -40 to +60

*6D 800 M6D 138-LA -5° F1b)/F2b)

3~ 230 Δ 60 1050 1.80 6.15 — 200 -40 to +60

A

B

C

Curv

e

Blad

e an

gle

Nom

inal

vol

tage

Freq

uenc

y

Spee

d (1

)

Max

. pow

er in

put (

1)

Max

. cur

rent

dra

w (1

)

Capa

cito

r

Max

. ope

rativ

e ra

nge

Perm

. am

p. te

mp.

Elec

tr. c

onne

ctio

n

(1) Nominal data in operating point with maximum load3subject to alterations

AC axial fans - HyBlade®

Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Insertion part made of sheet aluminium, extrusion-coated in PP plasticsRotor: Encased in aluminium

– Number of blades: 5– Direction of rotation: Direction of air flow "V" clockwise,

direction of air flow "A" counter-clockwise, seen on rotor– Type of protection: IP 54 (in accordance with EN 60529)– Insulation class: "F"– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request– Condensate discharge holes: Rotor-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearings

0

[Pa]

[in H

2O]

[m3/h]

[CFM]

80

40

160

120

200

0,2

0,4

0,3

0,5

0,6

0,7

0,8

A

B

C

2

3

1

2

3

1

0,1

4000 8000 12000 16000 20000

2000 4000 8000 10000 120006000

Curvesn

[rpm]

P1

[kW]

I

[A]

LwA

[dB(A)]

A

A

A

B

B

B

C

C

C

1

2

3

1

2

3

1

2

3

1130

1115

1100

1100

1075

1050

1100

1075

1050

1.51

1.75

1.98

1.41

1.62

1.80

1.41

1.62

1.80

77

78

80

77

77

79

77

77

79

3.04

3.30

3.60

2.95

3.27

3.55

5.13

5.69

6.15

3~ 480 Y 60 1080 2.18 3.80 — 150 -40 to +603~ 400 Y 60 1030 1.99 3.78 — 135 -40 to +603~ 230 Δ 60 1030 1.99 6.50 — 135 -40 to +60

D

E

F

Split by PDF Splitter

Page 2: Split by PDF Splitter AC axial fans - HyBlade · 2017-01-12 · 54 AC axial fans - HyBlade® Ø 800, drawings for direction of air flow "V" g±2 99x99 76 c±3 d±2 162 ±0,3 8xM10

51

– Motor protection: Design with thermal overload protector– Cable exit: Via terminal box– Protection class: I (in accordance with EN 61800-5-1)– Product conforming to standard: CE– Approvals: UL, VDE (in accordance with EN 60034)

Curves

4000 8000 12000 16000 20000

0

[Pa]

[in H

2O]

[m3/h]

[CFM]60003000 120009000

D

E

F

2

3

3

2

1

1

50

150

100

0,25

0,5

D

D

D

E

E

E

F

F

F

1

2

3

1

2

3

1

2

3

n

[rpm]

P1

[kW]

I

[A]

LwA

[dB(A)]

"V"

A6D 800-AE05 -03A6D 800-AE05 -04

A6D 800-AF05 -03A6D 800-AF05 -04

W6D 800-DE05 -04

W6D 800-GF05 -03W6D 800-DF05 -04

S6D 800-CF05 -03—

S6D 800-AF05 -03—

S6D 800-BE05 -04

—S6D 800-BF05 -04 —

——

W6D 800-GE05 -03 S6D 800-CE05 -03 S6D 800-AE05 -03 —

—"A"

"V""A"

Dire

ctio

n of

air

flow

Without attach-ments

With guard grille for full nozzle

With full squarenozzle

With guard grillefor short nozzle

With guard grille for full nozzle

With guard grillefor short nozzle

❮ "V"/ "A" ❯ ❮ "V"/ "A" ❯ ❮ "V" ❮ "V" "A" ❯ "A" ❯

Gen

era

l in

form

ati

on

AC

cen

trif

ug

al,

ba

ck

wa

rdA

C c

en

trif

ug

al,

forw

ard

Access

ori

es

Ele

ctr

ica

l co

nn

ecti

on

sR

ep

rese

nta

tive

sA

C a

xia

l fa

ns

Drawingsp. 54 f.

Motor protectionp. 122 f.

Electr. connectionsp. 126

1100

1090

1080

1060

1040

1030

1060

1040

1030

1.91

2.03

2.18

1.74

1.85

1.99

1.74

1.85

1.99

75

74

76

74

73

75

74

73

75

3.59

3.72

3.80

3.47

3.64

3.78

6.01

6.30

6.50

Split by PDF Splitter

Page 3: Split by PDF Splitter AC axial fans - HyBlade · 2017-01-12 · 54 AC axial fans - HyBlade® Ø 800, drawings for direction of air flow "V" g±2 99x99 76 c±3 d±2 162 ±0,3 8xM10

54

AC axial fans - HyBlade®

Ø 800, drawings for direction of air flow "V"

g±2

99x9

9

76

c±3

d±2

162±

0,3

8xM10

788±

2

Without attachmentsType

c

Mass

[kg]

A6D 800-AF05 -03A6D 800-AE05 -03A8D 800-AI09 -03A8D 800-AD05 -03AZD 800-AG07 -03

143.0

150.0

143.0

158.0

158.0

23.0

23.0

19.0

23.0

19.0

283±5

Ø857

19017

Ø14,

5

970-3

910±1

With full square nozzleType Mass

[kg]

W6D800-GF05 -03W6D800-GE05 -03W8D800-GI09 -03W8D800-GD05 -03WZD 800-GG07 -03

44.2

44.2

40.2

44.2

40.2

t±3

s±4108±3

Ø861

Ø816

With guard grille for full nozzleType

s

Mass

[kg]

S6D 800-CF05 -03S6D 800-CE05 -03S8D 800-CI09 -03S8D 800-CD05 -03SZD 800-CG07 -03

111.0

118.0

111.0

127.0

127.0

29.7

29.7

25.7

29.7

25.7

❮ "V"

❮ "V"

❮ "V"

Depth of screwmax. 18 mm

Screwed cable gland

View X 15±

0,5

7,5

92

26

6815,5

d

112.0

130.0

112.0

143.0

143.0

g

277.0

277.0

252.0

277.0

252.0

t

169.0

169.0

144.0

169.0

144.0

Internal diameter of thewall ring at least 795 mm

Internal diameter of thewall ring at least 795 mm

Split by PDF Splitter

Page 4: Split by PDF Splitter AC axial fans - HyBlade · 2017-01-12 · 54 AC axial fans - HyBlade® Ø 800, drawings for direction of air flow "V" g±2 99x99 76 c±3 d±2 162 ±0,3 8xM10

55

201±3 v±3

4

u±4

Ø929

10

Ø960

With guard grille for short nozzleType

u

Mass

[kg]

S6D 800-AF05 -03S6D 800-AE05 -03S8D 800-AI09 -03S8D 800-AD05 -03SZD 800-AG07 -03

18.0

25.0

18.0

34.0

34.0

30.0

30.0

26.0

30.0

26.0

❮ "V"

v

76.0

76.0

51.0

76.0

51.0

Internal diameter of thewall ring at least 795 mm

Gen

era

l in

form

ati

on

AC

cen

trif

ug

al,

ba

ck

wa

rdA

C c

en

trif

ug

al,

forw

ard

Access

ori

es

Ele

ctr

ica

l co

nn

ecti

on

sR

ep

rese

nta

tive

sA

C a

xia

l fa

ns

Split by PDF Splitter